Screening for atrial fibrillation during influenza vaccinations by primary care nurses using a smartphone electrocardiograph (iECG): A feasibility study
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: People with unknown atrial fibrillation (AF), who are often asymptomatic, have a substantially increased risk of stroke. Although recommended in European guidelines, AF screening is not routinely performed. Screening at the time of influenza vaccination presents an ideal opportunity to detect AF in large numbers in a primary care medical setting, with an existing annual recall system for patients aged ≥65 years. DESIGN: Cross-sectional pilot study of handheld smartphone electrocardiogram (iECG) screening to identify unknown AF. METHODS: General practices in Sydney, Australia, were recruited during the influenza-vaccination period of April-June 2015. Practice nurses screened patients aged ≥65 years with a 30-second iECG, which has a validated algorithm for detecting AF in real time. In order to confirm the accuracy of the algorithm, two research cardiologists reviewed de-identified iECGs. In order to explore barriers and enablers, semi-structured interviews were conducted with selected nurses, practice managers and general practitioners. RESULTS: Five general practices were recruited, and 973/2476 (39%) patients attending influenza vaccination were screened. Screening took an average of 5 minutes (range 1.5-10 minutes); however, abnormal iECGs required additional time. Newly identified AF was found in 8/973 patients (0.8%). The sensitivity of the iECG automated algorithm was 95% (95% confidence interval: 83-99%) and the specificity was 99% (95% confidence interval: 98-100%). Screening by practice nurses was well accepted by practice staff. Key enablers were the confidence and competence of nurses and a 'designated champion' to lead screening at the practice. Barriers were practice specific, and mainly related to staff time and funding. CONCLUSIONS: Screening with iECG during influenza vaccination by primary care nurses is feasible and well accepted by practice staff. Addressing barriers is likely to increase uptake.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lowres, N., Neubeck, L., Salkeld, G., Krass, I., McLachlan, A. J., Redfern, J., Bennett, A. A., Briffa, T., Bauman, A., Martinez, C., et al. (2014) · Thrombosis and Haemostasis · doi:10.1160/th14-03-0231 · Cited by 458
Self-citationHobbs, F., Fitzmaurice, D., Mant, J., Murray, E., Jowett, S., Bryan, S., Raftery, J., Davies, M., & Lip, G. (2005) · Health Technology Assessment · doi:10.3310/hta9400 · Cited by 437
Lau, J. K., Lowres, N., Neubeck, L., Brieger, D. B., Sy, R. W., Galloway, C. D., Albert, D. E., & Freedman, S. B. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.220 · Cited by 326
Self-citationValidation and clinical use of a novel diagnostic device for screening of atrial fibrillation
Tieleman, R. G., Plantinga, Y., Rinkes, D., Bartels, G. L., Posma, J. L., Cator, R., Hofman, C., & Houben, R. P. (2014) · Europace · doi:10.1093/europace/euu057 · Cited by 138 · cited 1×
“A study in The Netherlands found that screening patients aged >65 years for AF during flu vaccination in the general practice setting was promising.(12) In Australia, the annual flu-vaccination programme is well entrenched and has excellent uptake, and is a time when patients are likely to be available and receptive t…”
Background
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Self-citationSelf-powered cardiovascular electronic devices and systems
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0426-4 · Cited by 348
Jacob, C., Sanchez-Vazquez, A., & Ivory, C. (2020) · JMIR mHealth and uHealth · doi:10.2196/15935 · Cited by 292
Metadata
- Authors
- Orchard, J., Lowres, N., Freedman, S. B., Ladak, L., Lee, W., Zwar, N., Peiris, D., Kamaladasa, Y., Li, J., & Neubeck, L.
- Venue
- European Journal of Preventive Cardiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-10
- Volume
- 23
- Issue
- 2_suppl
- Pages
- 13-20
- ISSN
- 2047-4873 (ISSN-L)
- 2047-4881
- OpenAlex
- W2544182322
- Cited by
- 100
- References
- 4
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screening for atrial fibrillation during influenza vaccinations by primary care nurses using a smartphone electrocardiograph (iECG): A feasibility study. https://app.cochat.ai/papers/10.1177/2047487316670255
- The paper
- Orchard, J., Lowres, N., Freedman, S. B., Ladak, L., Lee, W., Zwar, N., Peiris, D., Kamaladasa, Y., Li, J., & Neubeck, L. (2016). Screening for atrial fibrillation during influenza vaccinations by primary care nurses using a smartphone electrocardiograph (iECG): A feasibility study. European Journal of Preventive Cardiology. https://doi.org/10.1177/2047487316670255
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.