CoChat

Self-powered cardiovascular electronic devices and systems

Zheng, Qiang, Tang, Qizhu, Wang, Zhong Lin, Li, Zhou · 2021 · Nature Reviews Cardiology

The DOI matches its Crossref record; 135 of the 136 references it cites were found in a registry or an index.

Abstract

Cardiovascular electronic devices have enormous benefits for health and quality of life but the long-term operation of these implantable and wearable devices remains a huge challenge owing to the limited life of batteries, which increases the risk of device failure and causes uncertainty among patients. A possible approach to overcoming the challenge of limited battery life is to harvest energy from the body and its ambient environment, including biomechanical, solar, thermal and biochemical energy, so that the devices can be self-powered. This strategy could allow the development of advanced features for cardiovascular electronic devices, such as extended life, miniaturization to improve comfort and conformability, and functions that integrate with real-time data transmission, mobile data processing and smart power utilization. In this Review, we present an update on self-powered cardiovascular implantable electronic devices and wearable active sensors. We summarize the existing self-powered technologies and their fundamental features. We then review the current applications of self-powered electronic devices in the cardiovascular field, which have two main goals. The first is to harvest energy from the body as a sustainable power source for cardiovascular electronic devices, such as cardiac pacemakers. The second is to use self-powered devices with low power consumption and high performance as active sensors to monitor physiological signals (for example, for active endocardial monitoring). Finally, we present the current challenges and future perspectives for the field.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41569-020-0426-4

Cites

135 of 135 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 135 references

Research works printed but not linked: 4

  1. Teplitzky, B. A. & McRoberts, M. in 2018 IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks (BSN) 58–61 (IEEE, 2018).
  2. Selvaraj, N. in 2014 IEEE Healthcare Innovations Conference (HIC) 83–86 (IEEE, 2014).
  3. Burleson, W., Clark, S. S., Ransford, B. & Fu, K. in DAC Design Automation Conference 2012 12–17 (IEEE, 2012).
  4. Hovel, H. J. in Semiconductors and Semimetals Vol. 11 (eds Willardson, R. K. & Beer, A. C.) 181–207 (Academic Press, 1975).

Cited by

See all 355

Metadata

Authors
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Renmin Hospital of Wuhan University (CN)
  • Georgia Institute of Technology (US)
Corresponding author
  • Wang, Zhong Lin
  • Li, Zhou
Venue
Nature Reviews Cardiology
Published
2020-09-07
Volume
18
Issue
1
Pages
7-21
ISSN
  • 1759-5002 (ISSN-L)
  • 1759-5010
OpenAlex
W3084056592
Cited by
348
References
136
Citations by year
2026: 28 · 2025: 56 · 2024: 66 · 2023: 72 · 2022: 55 · 2021: 65 · 2020: 6
FWCI
3.82
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Nature Reviews Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
self-powered devices, energy harvesting, implantable electronics, wearable sensors, cardiac pacemaker, low-power sensors, physiological monitoring, battery life
MeSH terms
Wearable Electronic Devices, Cardiovascular Diseases, Cardiovascular System, Humans, Electric Power Supplies

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-powered cardiovascular electronic devices and systems. https://app.cochat.ai/papers/10.1038/s41569-020-0426-4
The paper
Zheng, Q., Tang, Q., Wang, Z. L., & Li, Z. (2021). Self-powered cardiovascular electronic devices and systems. Nature Reviews Cardiology. https://doi.org/10.1038/s41569-020-0426-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.