Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered?
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Aims: In the rehabilitation of cardiovascular disease patients a correct determination of the endurance-type exercise intensity is important to generate health benefits and preserve medical safety. It remains to be assessed whether the guideline-based exercise intensity domains are internally consistent and agree with physiological responses to exercise in cardiovascular disease patients. Methods: A total of 272 cardiovascular disease patients without pacemaker executed a maximal cardiopulmonary exercise test on bike (peak respiratory gas exchange ratio >1.09), to assess peak heart rate (HR peak), oxygen uptake (VO 2peak) and cycling power output (W peak). The first and second ventilatory threshold (VT1 and VT2, respectively) was determined and extrapolated to %VO 2peak, %HR peak, %heart rate reserve (%HRR) and %W peak for comparison with guideline-based exercise intensity domains. Results: VT1 was noted at 62 ± 10% VO 2peak, 75 ± 10% HR peak, 42 ± 14% HRR and 47 ± 11% W peak, corresponding to the high intensity exercise domain (for %VO 2peak and %HR peak) or low intensity exercise domain (for %W peak and %HRR). VT2 was noted at 84 ± 9% VO 2peak, 88 ± 8% HR peak, 74 ± 15% HRR and 76 ± 11% W peak, corresponding to the high intensity exercise domain (for %HRR and %W peak) or very hard exercise domain (for %HR peak and %VO 2peak). At best (when using %W peak) in only 63% and 72% of all patients VT1 and VT2, respectively, corresponded to the same guideline-based exercise intensity domain, but this dropped to about 48% and 52% at worst (when using %HRR and %HR peak, respectively). In particular, the patient’s VO 2peak related to differently elicited guideline-based exercise intensity domains ( P < 0.05). Conclusion: The guideline-based exercise intensity domains for cardiovascular disease patients seem inconsistent, thus reiterating the need for adjustment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Garber, C. E., Blissmer, B., Deschenes, M. R., Franklin, B. A., Lamonte, M. J., Lee, I.-M., Nieman, D. C., & Swain, D. P. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318213fefb · Cited by 9,319
2016 European Guidelines on cardiovascular disease prevention in clinical practice
Piepoli, M. F., Hoes, A. W., Agewall, S., Albus, C., Brotons, C., Catapano, A. L., Cooney, M.-T., Corrà, U., Cosyns, B., Deaton, C., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw106 · Cited by 6,457
Fletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235
Piepoli, M. F., Corrà, U., Benzer, W., Bjarnason-Wehrens, B., Dendale, P., Gaita, D., McGee, H., Mendes, M., Niebauer, J., Zwisler, A.-D. O., et al. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e3283313592 · Cited by 796
Self-citationMezzani, A., Hamm, L. F., Jones, A. M., McBride, P. E., Moholdt, T., Stone, J. A., Urhausen, A., & Williams, M. A. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487312460484 · Cited by 550
Hansen, D., Niebauer, J., Cornelissen, V., Barna, O., Neunhäuserer, D., Stettler, C., Tonoli, C., Greco, E., Fagard, R., Coninx, K., et al. (2018) · Sports Medicine · doi:10.1007/s40279-018-0930-4 · Cited by 191 · cited 1×
“For example, to reduce blood pressure, increase endurance exercise capacity in a time-efficient manner, and elicit a significant energy expenditure during endurance exercise (to reduce adipose tissue mass) at least moderate intensity exercise is advised.(14,15) Moreover, to prevent adverse cardiovascular events during…”
BackgroundSelf-citationGomes-Neto, M., Durães, A. R., Reis, H. F. C. D., Neves, V. R., Martinez, B. P., & Carvalho, V. O. (2017) · European Journal of Preventive Cardiology · doi:10.1177/2047487317728370 · Cited by 151
Cited by
Ambrosetti, M., Abreu, A., Corrà, U., Davos, C. H., Hansen, D., Frederix, I., Iliou, M. C., Pedretti, R. F. E., Schmid, J.-P., Vigorito, C., et al. (2021) · European Journal of Preventive Cardiology · doi:10.1177/2047487320913379 · Cited by 965
Self-citationHansen, D., Abreu, A., Ambrosetti, M., Cornelissen, V., Gevaert, A., Kemps, H., Laukkanen, J. A., Pedretti, R., Simonenko, M., Wilhelm, M., et al. (2022) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwab007 · Cited by 321
Self-citationIdentification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Meyler, S., Bottoms, L., Wellsted, D., & Muniz‐Pumares, D. (2023) · Experimental Physiology · doi:10.1113/ep090878 · Cited by 66
Metadata
- Authors
- Hansen, D., Bonné, K., Alders, T., Hermans, A., Copermans, K., Swinnen, H., Maris, V., Jansegers, T., Mathijs, W., Haenen, L., Vaes, J., Govaerts, E., Reenaers, V., Frederix, I., & Dendale, P.
- Venue
- European Journal of Preventive Cardiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-06-20
- Volume
- 26
- Issue
- 18
- Pages
- 1921-1928
- ISSN
- 2047-4873 (ISSN-L)
- 2047-4881
- OpenAlex
- W2952069360
- Cited by
- 88
- References
- 7
- FWCI
- 11.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered? https://app.cochat.ai/papers/10.1177/2047487319859450
- The paper
- Hansen, D., Bonné, K., Alders, T., Hermans, A., Copermans, K., Swinnen, H., Maris, V., Jansegers, T., Mathijs, W., Haenen, L., Vaes, J., Govaerts, E., Reenaers, V., Frederix, I., & Dendale, P. (2019). Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered? European Journal of Preventive Cardiology. https://doi.org/10.1177/2047487319859450
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.