CoChat

Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered?

Hansen, Dominique, Bonné, Kim, Alders, Toon, Hermans, Ann, Copermans, Katrien, Swinnen, Hans, Maris, Vincent, Jansegers, Thomas, Mathijs, Wout, Haenen, Laura, Vaes, Johan, Govaerts, Emmanuela, Reenaers, Veerle, Frederix, Ines, Dendale, Paul · 2019 · European Journal of Preventive Cardiology
Cited by 88

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Aims: In the rehabilitation of cardiovascular disease patients a correct determination of the endurance-type exercise intensity is important to generate health benefits and preserve medical safety. It remains to be assessed whether the guideline-based exercise intensity domains are internally consistent and agree with physiological responses to exercise in cardiovascular disease patients. Methods: A total of 272 cardiovascular disease patients without pacemaker executed a maximal cardiopulmonary exercise test on bike (peak respiratory gas exchange ratio >1.09), to assess peak heart rate (HR peak), oxygen uptake (VO 2peak) and cycling power output (W peak). The first and second ventilatory threshold (VT1 and VT2, respectively) was determined and extrapolated to %VO 2peak, %HR peak, %heart rate reserve (%HRR) and %W peak for comparison with guideline-based exercise intensity domains. Results: VT1 was noted at 62 ± 10% VO 2peak, 75 ± 10% HR peak, 42 ± 14% HRR and 47 ± 11% W peak, corresponding to the high intensity exercise domain (for %VO 2peak and %HR peak) or low intensity exercise domain (for %W peak and %HRR). VT2 was noted at 84 ± 9% VO 2peak, 88 ± 8% HR peak, 74 ± 15% HRR and 76 ± 11% W peak, corresponding to the high intensity exercise domain (for %HRR and %W peak) or very hard exercise domain (for %HR peak and %VO 2peak). At best (when using %W peak) in only 63% and 72% of all patients VT1 and VT2, respectively, corresponded to the same guideline-based exercise intensity domain, but this dropped to about 48% and 52% at worst (when using %HRR and %HR peak, respectively). In particular, the patient’s VO 2peak related to differently elicited guideline-based exercise intensity domains ( P < 0.05). Conclusion: The guideline-based exercise intensity domains for cardiovascular disease patients seem inconsistent, thus reiterating the need for adjustment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2047487319859450

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 88

Metadata

Authors
Hansen, D., Bonné, K., Alders, T., Hermans, A., Copermans, K., Swinnen, H., Maris, V., Jansegers, T., Mathijs, W., Haenen, L., Vaes, J., Govaerts, E., Reenaers, V., Frederix, I., & Dendale, P.
Venue
European Journal of Preventive Cardiology
Published
2019-06-20
Volume
26
Issue
18
Pages
1921-1928
ISSN
  • 2047-4873 (ISSN-L)
  • 2047-4881
OpenAlex
W2952069360
Cited by
88
References
7
FWCI
11.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered? https://app.cochat.ai/papers/10.1177/2047487319859450
The paper
Hansen, D., Bonné, K., Alders, T., Hermans, A., Copermans, K., Swinnen, H., Maris, V., Jansegers, T., Mathijs, W., Haenen, L., Vaes, J., Govaerts, E., Reenaers, V., Frederix, I., & Dendale, P. (2019). Exercise training intensity determination in cardiovascular rehabilitation: Should the guidelines be reconsidered? European Journal of Preventive Cardiology. https://doi.org/10.1177/2047487319859450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.