Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 183

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Transient attenuation of the amplitude of the QRS complexes in the diagnosis of Takotsubo syndrome

Open access
Madias, John E · 2014 · European Heart Journal: Acute Cardiovascular Care

Abstract

BACKGROUND AND OBJECTIVES: Currently, there are no specific diagnostic electrocardiogram (ECG) signs for Takotsubo syndrome (TTS) to differentiate it from acute coronary syndromes (ACS). Myocardial oedema has been detected by cardiac magnetic resonance imaging in patients with TTS. Recently it has been postulated that myocardial oedema may be the cause of low QRS voltage (LQRSV) in the admission ECG and attenuation of the amplitude of the QRS complexes (AAQRS) in serial ECGs, noted in a few published cases of patients with TTS. The objective of this study was to evaluate whether the admission ECG of patients with documented TTS reveals LQRSV and whether AAQRS is found when serial ECGs are compared in such patients. METHODS: This study evaluated the prevalence of LQRSV in the admission ECG and AAQRS in serial ECGs in patients with TTS. ECGs of 368 patients with TTS from published reports in the international literature were evaluated for LQRSV (≤5 mm in limb leads and/or ≤10 mm in precordial leads) and AAQRS in serial ECGs. RESULTS: LQRSV was seen in 91.5% of 200 patients with TTS and one ECG, with a distribution of 49.0, 42.8, 51.0, 52.0, and 46.9%, in lead aVR, and inferior, anterior, lateral, and high lateral ECG lead groups, respectively. AAQRS was seen in 93.5% of 168 patients with TTS and two or more ECGs, with a distribution of 78.3, 74.5, 60.1, 70.7, and 74.5% in lead aVR, and inferior, anterior, lateral, and high lateral ECG lead groups, respectively. CONCLUSIONS: LQRSV and AAQRS are highly prevalent ECG signs in patients with TTS, and should be useful in aiding in its diagnosis and differentiation from ACS, on first contact with the patient on admission to the hospital, and the ensuing 24 hours, in conjunction with echocardiography and coronary arteriography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2048872613504311

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Madias, J. E.
Venue
European Heart Journal: Acute Cardiovascular Care
Published
2013-09-18
Volume
3
Issue
1
Pages
28-36
ISSN
  • 2048-8726 (ISSN-L)
  • 2048-8734
OpenAlex
W2146771722
Cited by
183
References
1
FWCI
23.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transient attenuation of the amplitude of the QRS complexes in the diagnosis of Takotsubo syndrome. https://app.cochat.ai/papers/10.1177/2048872613504311
The paper
Madias, J. E. (2014). Transient attenuation of the amplitude of the QRS complexes in the diagnosis of Takotsubo syndrome. European Heart Journal: Acute Cardiovascular Care. https://doi.org/10.1177/2048872613504311

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.