CoChat

Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure

Ferri, Luca A., Farina, Andrea, Lenatti, Laura, Ruffa, Franco, Tiberti, GianLuca, Piatti, Luigi, Savonitto, Stefano · 2016 · European Heart Journal: Acute Cardiovascular Care
Cited by 44

The DOI matches its Crossref record.

Abstract

AIMS: To compare time to active pacing and complication rates associated with temporary transvenous pacemaker (TTVPM) insertion between a fully echo-guided approach of vein access and lead placement, and standard placement of TTVPM under fluoroscopic guidance. METHODS AND RESULTS: We performed a prospective single-center observational study enrolling all consecutive patients from 1 January 2008 to 31 December 2012 needing emergent TTVPM placement. According to personal experience and clinical setting, the operators could choose between a fully echo-guided approach of TTVPM placement through the jugular vein and a standard fluoro-guided approach through the femoral vein. Safety and efficacy endpoints were pre-specified, registered, and compared. A total of 113 patients were treated using the echo-guided approach, and 90 via the fluoro-guided approach. The two groups differed with regard to clinical setting at presentation: an acute coronary syndrome was more frequent in the fluoro-guided approach group (39.7% vs. 16.8%, p<0.001), whereas asystole was more frequent in the echo-guided approach group (9.7 vs. 0%). Median time from decision to active pacing was significantly shorter in the echo-guided approach group (22 vs. 43 minutes, p<0.01). The overall complication rates were significantly lower in the echo-guided approach group (15.0% vs. 28.8%, p 0.02), because of lower rates of infections (2.7% vs. 11.1%, p 0.02) and puncture-related hematomas (0 vs. 3.3%, p=0.08). There were no deaths related to TTVPM, but one heart perforation requiring emergent pericardiocentesis occurred in the fluoro-guided approach group. One pneumothorax treated conservatively occurred in the echo-guided approach group, while no differences were observed with regard to sustained tachyarrhythmias (1.8% vs. 2.2%) or malfunctions requiring reposition of the catheter (8.8 vs. 8.9%). Overall, complications delaying permanent pacemaker implant for >48 hours were observed less often in the echo-guided approach group (6.8 vs. 20.7%, p = 0.03). CONCLUSION: Echo-guided insertion of TTVPM through the jugular vein is a feasible and safe alternative to fluoroscopic guidance and may reduce complications and time to active pacing in patients who are not candidates for emergent cardiac catheterization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/2048872615572598

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 44

Metadata

Authors
Ferri, L. A., Farina, A., Lenatti, L., Ruffa, F., Tiberti, G., Piatti, L., & Savonitto, S.
Venue
European Heart Journal: Acute Cardiovascular Care
Published
2015-02-11
Volume
5
Issue
2
Pages
125-129
ISSN
  • 2048-8726 (ISSN-L)
  • 2048-8734
OpenAlex
W2017804733
Cited by
44
References
0
FWCI
2.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure. https://app.cochat.ai/papers/10.1177/2048872615572598
The paper
Ferri, L. A., Farina, A., Lenatti, L., Ruffa, F., Tiberti, G., Piatti, L., & Savonitto, S. (2016). Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure. European Heart Journal: Acute Cardiovascular Care. https://doi.org/10.1177/2048872615572598

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.