Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure
The DOI matches its Crossref record.
Abstract
AIMS: To compare time to active pacing and complication rates associated with temporary transvenous pacemaker (TTVPM) insertion between a fully echo-guided approach of vein access and lead placement, and standard placement of TTVPM under fluoroscopic guidance. METHODS AND RESULTS: We performed a prospective single-center observational study enrolling all consecutive patients from 1 January 2008 to 31 December 2012 needing emergent TTVPM placement. According to personal experience and clinical setting, the operators could choose between a fully echo-guided approach of TTVPM placement through the jugular vein and a standard fluoro-guided approach through the femoral vein. Safety and efficacy endpoints were pre-specified, registered, and compared. A total of 113 patients were treated using the echo-guided approach, and 90 via the fluoro-guided approach. The two groups differed with regard to clinical setting at presentation: an acute coronary syndrome was more frequent in the fluoro-guided approach group (39.7% vs. 16.8%, p<0.001), whereas asystole was more frequent in the echo-guided approach group (9.7 vs. 0%). Median time from decision to active pacing was significantly shorter in the echo-guided approach group (22 vs. 43 minutes, p<0.01). The overall complication rates were significantly lower in the echo-guided approach group (15.0% vs. 28.8%, p 0.02), because of lower rates of infections (2.7% vs. 11.1%, p 0.02) and puncture-related hematomas (0 vs. 3.3%, p=0.08). There were no deaths related to TTVPM, but one heart perforation requiring emergent pericardiocentesis occurred in the fluoro-guided approach group. One pneumothorax treated conservatively occurred in the echo-guided approach group, while no differences were observed with regard to sustained tachyarrhythmias (1.8% vs. 2.2%) or malfunctions requiring reposition of the catheter (8.8 vs. 8.9%). Overall, complications delaying permanent pacemaker implant for >48 hours were observed less often in the echo-guided approach group (6.8 vs. 20.7%, p = 0.03). CONCLUSION: Echo-guided insertion of TTVPM through the jugular vein is a feasible and safe alternative to fluoroscopic guidance and may reduce complications and time to active pacing in patients who are not candidates for emergent cardiac catheterization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2022) · EP Europace · doi:10.1093/europace/euab232 · Cited by 914
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- Ferri, L. A., Farina, A., Lenatti, L., Ruffa, F., Tiberti, G., Piatti, L., & Savonitto, S.
- Venue
- European Heart Journal: Acute Cardiovascular Care
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-02-11
- Volume
- 5
- Issue
- 2
- Pages
- 125-129
- ISSN
- 2048-8726 (ISSN-L)
- 2048-8734
- OpenAlex
- W2017804733
- Cited by
- 44
- References
- 0
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure. https://app.cochat.ai/papers/10.1177/2048872615572598
- The paper
- Ferri, L. A., Farina, A., Lenatti, L., Ruffa, F., Tiberti, G., Piatti, L., & Savonitto, S. (2016). Emergent transvenous cardiac pacing using ultrasound guidance: a prospective study versus the standard fluoroscopy-guided procedure. European Heart Journal: Acute Cardiovascular Care. https://doi.org/10.1177/2048872615572598
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.