CoChat

Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome

Open access

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Intra-laboratory turnaround time (TAT) is a key indicator of laboratory performance. Improving TAT is a complex task requiring staff education, equipment acquisition, and adequate TAT monitoring. The aim of the present study was to evaluate the intra-laboratory TAT after laboratory automation implementation (June 2013-June 2014) and to compare it to that in the preautomation period (July 2012-May 2013). Intra-laboratory TAT was evaluated both as the mean TAT registered and the percentage of outlier (OP) exams. The mean TAT was 36, 38, and 34 min during the study periods, respectively. These values respected the goal TAT established at 45 min. The OP, calculated at 45 min as well as at 60 min, decreased from 26 to 21 and from 11 to 5, respectively. From a focused analysis on blood count cell, troponin I, and prothrombin (PT) test, TAT improvement was more evident for tests requiring longer preanalytical process. The follow-up of TAT from June 2013 to June 2014 revealed the reduction of the mean TAT as well as of the OP exams after automation implementation and that automation more strongly affects the test in the preanalytical phase including centrifugation of the sample, such as troponin I and PT.

Overview

Integrity signals

Registry

Crossref · 10.1177/2211068214566458

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 14 references

Research works printed but not linked: 1

  1. Angeletti, 2014, Monitoring and Improvement of Intra Laboratory Turnaround Time at the University Hospital Campus Bio-Medico in Rome, Biochim. Clin., 38, 115

Cited by

See all 49

Metadata

Authors
Angeletti, S., De Cesaris, M., Hart, J. G., Urbano, M., Vitali, M. A., Fragliasso, F., & Dicuonzo, G.
Affiliations
  • Università Campus Bio-Medico (IT)
  • Campus Bio Medico University Hospital (IT)
Corresponding author
Angeletti, Silvia
Venue
SLAS Technology
Publisher
Elsevier BV
Published
2015-12
Volume
20
Issue
6
Pages
652-658
ISSN
2472-6303 (ISSN-L)
OpenAlex
W1995321013
Cited by
38
References
13
Citations by year
2026: 2 · 2025: 4 · 2024: 6 · 2023: 4 · 2022: 3 · 2021: 2 · 2020: 4 · 2019: 7 · 2018: 1 · 2017: 4 · 2016: 1
FWCI
1.47
Type
journal article
Language
en
Open access
Licence
Locations
  • SLAS TECHNOLOGY (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
Keywords
laboratory automation, pre-analytical phase, troponin I, prothrombin time
MeSH terms
Diagnostic Tests, Routine, Hospitals, University, Humans, Rome, Time Factors, Automation, Laboratory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome. https://app.cochat.ai/papers/10.1177/2211068214566458
The paper
Angeletti, S., De Cesaris, M., Hart, J. G., Urbano, M., Vitali, M. A., Fragliasso, F., & Dicuonzo, G. (2015). Laboratory Automation and Intra-Laboratory Turnaround Time: Experience at the University Hospital Campus Bio-Medico of Rome. SLAS Technology. https://doi.org/10.1177/2211068214566458

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.