Abstract

The transition to total automation represents the greatest leap for a clinical laboratory, characterized by a totally new philosophy of process management. We have investigated the impact of total automation on core laboratory efficiency and its effects on the clinical services related to STAT tests. For this purpose, a 47-month retrospective study based on the analysis of 44,212 records of STAT cardiac troponin I (CTNI) tests was performed. The core laboratory reached a new efficiency level 3 months after the implementation of total automation. Median turnaround time (TAT) was reduced by 14.9±1.5 min for the emergency department (p < 0.01), reaching 41.6±1.2 min. In non-emergency departments, median TAT was reduced by 19.8±2.2 min (p < 0.01), reaching 52±1.3 min. There was no change in the volume of ordered STAT CTNI tests by the emergency department (p = 0.811), whereas for non-emergency departments there was a reduction of 115.7±50 monthly requests on average (p = 0.026). The volume of ordered tests decreased only in time frames of the regular shift following the morning round. Thus, total automation significantly improves the core laboratory efficiency in terms of TAT. As a consequence, the volume of STAT tests ordered by hospital departments (except for the emergency department) decreased due to reduced duplicated requests.

Overview

Integrity signals

Registry

Crossref · 10.1177/2211068215581488

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Research works printed but not linked: 2

  1. Godolphin, 1992, Simulation Modelling: A Tool to Help Predict the Impact of Automation in Clinical Laboratory, Lab. Robot. Autom., 4, 249
  2. Brannon Thomas, 2008, The Impact of Laboratory Automation on Performance Improvement, Fed. Pract., 25, 14

Cited by

See all 42

Metadata

Authors
Ialongo, C., Porzio, O., Giambini, I., & Bernardini, S.
Affiliations
University of Rome Tor Vergata (IT)
Corresponding author
Ialongo, Cristiano
Venue
SLAS Technology
Publisher
Elsevier BV
Published
2016-06
Volume
21
Issue
3
Pages
451-458
ISSN
2472-6303 (ISSN-L)
OpenAlex
W2010183570
Cited by
42
References
30
Citations by year
2026: 5 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 8 · 2018: 2 · 2017: 4 · 2016: 3
FWCI
2.21
Type
journal article
Language
en
Open access
Licence
Locations
  • SLAS TECHNOLOGY (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
Keywords
core laboratory, turnaround time, cardiac troponin I, emergency department, laboratory efficiency, process management
MeSH terms
Diagnostic Tests, Routine, Humans, Myocardial Infarction, Retrospective Studies, Time Factors, Troponin I, Clinical Laboratory Techniques, Automation, Laboratory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests. https://app.cochat.ai/papers/10.1177/2211068215581488
The paper
Ialongo, C., Porzio, O., Giambini, I., & Bernardini, S. (2016). Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests. SLAS Technology. https://doi.org/10.1177/2211068215581488

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.