Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The transition to total automation represents the greatest leap for a clinical laboratory, characterized by a totally new philosophy of process management. We have investigated the impact of total automation on core laboratory efficiency and its effects on the clinical services related to STAT tests. For this purpose, a 47-month retrospective study based on the analysis of 44,212 records of STAT cardiac troponin I (CTNI) tests was performed. The core laboratory reached a new efficiency level 3 months after the implementation of total automation. Median turnaround time (TAT) was reduced by 14.9±1.5 min for the emergency department (p < 0.01), reaching 41.6±1.2 min. In non-emergency departments, median TAT was reduced by 19.8±2.2 min (p < 0.01), reaching 52±1.3 min. There was no change in the volume of ordered STAT CTNI tests by the emergency department (p = 0.811), whereas for non-emergency departments there was a reduction of 115.7±50 monthly requests on average (p = 0.026). The volume of ordered tests decreased only in time frames of the regular shift following the morning round. Thus, total automation significantly improves the core laboratory efficiency in terms of TAT. As a consequence, the volume of STAT tests ordered by hospital departments (except for the emergency department) decreased due to reduced duplicated requests.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Efficient TAT, coupled with robust critical value reporting protocols, is essential for closing the loop on abnormal findings and ensuring they are acted upon [20].”
From Impact of Laboratory Turnaround Time on Clinical Decision-Making and Patient Outcomes (2024) · cites this paper as [20]
In the citing paper
“Such improvements have been shown to reduce the TAT [26–30].”
From Shorter laboratory turnaround time is associated with shorter emergency department length of stay: a retrospective cohort study (2022) · cites this paper as [26]
Citations
Cites
Writing Committee Members, Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., et al. (2004) · Circulation · doi:10.1161/01.cir.0000134791.68010.fa · Cited by 8,356
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
Braunwald, E., Antman, E. M., Beasley, J. W., Califf, R. M., Cheitlin, M. D., Hochman, J. S., Jones, R. H., Kereiakes, D., Kupersmith, J., Levin, T. N., et al. (2000) · Circulation · doi:10.1161/01.cir.102.10.1193 · Cited by 4,487
Segmented regression analysis of interrupted time series studies in medication use research
Wagner, A. K., Soumerai, S. B., Zhang, F., & Ross-Degnan, D. (2002) · Journal of Clinical Pharmacy and Therapeutics · doi:10.1046/j.1365-2710.2002.00430.x · Cited by 3,279 · cited 1×
“However, if the ordinary least squares regression is chosen, results may be unreliable because of autocorrelation that arises in data due to the way they are collected (serially) throughout time.(26) In our case, a longer period of observation allowed us to recognize the presence of some change points in the trend tha…”
Method2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction
O'Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., Franklin, B. A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.019 · Cited by 2,625
Intervention Analysis with Applications to Economic and Environmental Problems
Box, G. E. P., & Tiao, G. C. (1975) · Journal of the American Statistical Association · doi:10.1080/01621459.1975.10480264 · Cited by 2,383
Hawkins, R. C. (2007) · PubMed · Cited by 404
Newby, L. K., Jesse, R. L., Babb, J. D., Christenson, R. H., De Fer, T. M., Diamond, G. A., Fesmire, F. M., Geraci, S. A., Gersh, B. J., Larsen, G. C., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.969 · Cited by 402
How to do (or not to do) … Assessing the impact of a policy change with routine longitudinal data
Lagarde, M. (2012) · Health Policy and Planning · doi:10.1093/heapol/czr004 · Cited by 290
2007 WRITING COMMITTEE MEMBERS, Anderson, J. L., Adams, C. D., Antman, E. M., Bridges, C. R., Califf, R. M., Casey, D. E., Chavey, W. E., Fesmire, F. M., Hochman, J. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31828478ac · Cited by 272
Research works printed but not linked: 2
- Godolphin, 1992, Simulation Modelling: A Tool to Help Predict the Impact of Automation in Clinical Laboratory, Lab. Robot. Autom., 4, 249
- Brannon Thomas, 2008, The Impact of Laboratory Automation on Performance Improvement, Fed. Pract., 25, 14
Cited by
Automation and artificial intelligence in the clinical laboratory
Naugler, C., & Church, D. L. (2019) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1561640 · Cited by 112
“outlier examinations and the demand for STAT testing [19,21,33,34].”
BackgroundVrijsen, B. E. L., Haitjema, S., Westerink, J., Hulsbergen-Veelken, C. A. R., van Solinge, W. W., & ten Berg, M. J. (2022) · BMC Emergency Medicine · doi:10.1186/s12873-022-00763-w · Cited by 20
Impact of Laboratory Turnaround Time on Clinical Decision-Making and Patient Outcomes
Alanazi, A. G. J., Hanbouli, T. M. H. A., Albarqi, A. S. M., Aldoghmani Turki Kateb, D., Rowili, N. H. O. A., Jhory, K. E. A., Bokhari, A. M. K., Alanazi, A. A., Alenezi, T. M. R., Alawidia Ahmad Issa, A., et al. (2024) · International Journal of Computational and Experimental Science and Engineering · doi:10.22399/ijcesen.4675 · Cited by 1
Metadata
- Authors
- Ialongo, C., Porzio, O., Giambini, I., & Bernardini, S.
- Affiliations
- University of Rome Tor Vergata (IT)
- Corresponding author
- Ialongo, Cristiano
- Venue
- SLAS Technology
- Publisher
- Elsevier BV
- Published
- 2016-06
- Volume
- 21
- Issue
- 3
- Pages
- 451-458
- ISSN
- 2472-6303 (ISSN-L)
- OpenAlex
- W2010183570
- Cited by
- 42
- References
- 30
- Citations by year
- 2026: 5 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 8 · 2018: 2 · 2017: 4 · 2016: 3
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 2130 d)
- Locations
- SLAS TECHNOLOGY (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Cineca Institutional Research Information System (Tor Vergata University) (submittedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Keywords
- core laboratory, turnaround time, cardiac troponin I, emergency department, laboratory efficiency, process management
- MeSH terms
- Diagnostic Tests, Routine, Humans, Myocardial Infarction, Retrospective Studies, Time Factors, Troponin I, Clinical Laboratory Techniques, Automation, Laboratory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests. https://app.cochat.ai/papers/10.1177/2211068215581488
- The paper
- Ialongo, C., Porzio, O., Giambini, I., & Bernardini, S. (2016). Total Automation for the Core Laboratory: Improving the Turnaround Time Helps to Reduce the Volume of Ordered STAT Tests. SLAS Technology. https://doi.org/10.1177/2211068215581488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.