Recommended Guidelines for Developing, Qualifying, and Implementing Complex In Vitro Models (CIVMs) for Drug Discovery
Open accessThe DOI matches its Crossref record; 89 of the 89 references it cites were found in a registry or an index.
Abstract
The pharmaceutical industry is continuing to face high research and development (R&D) costs and low overall success rates of clinical compounds during drug development. There is an increasing demand for development and validation of healthy or disease-relevant and physiological human cellular models that can be implemented in early-stage discovery, thereby shifting attrition of future therapeutics to a point in discovery at which the costs are significantly lower. There needs to be a paradigm shift in the early drug discovery phase (which is lengthy and costly), away from simplistic cellular models that show an inability to effectively and efficiently reproduce healthy or human disease-relevant states to steer target and compound selection for safety, pharmacology, and efficacy questions. This perspective article covers the various stages of early drug discovery from target identification (ID) and validation to the hit/lead discovery phase, lead optimization, and preclinical safety. We outline key aspects that should be considered when developing, qualifying, and implementing complex in vitro models (CIVMs) during these phases, because criteria such as cell types (e.g., cell lines, primary cells, stem cells, and tissue), platform (e.g., spheroids, scaffolds or hydrogels, organoids, microphysiological systems, and bioprinting), throughput, automation, and single and multiplexing endpoints will vary. The article emphasizes the need to adequately qualify these CIVMs such that they are suitable for various applications (e.g., context of use) of drug discovery and translational research. The article ends looking to the future, in which there is an increase in combining computational modeling, artificial intelligence and machine learning (AI/ML), and CIVMs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Most OoCs developed in an academic setting are not designed with qualification in mind, causing a large gap between the development and qualification of models (Ekert et al., 2020).”
From Considering future qualification for regulatory science in the early development of microphysiological systems: a case study of microthrombosis in a Vessel-on-Chip (2024) · cites this paper as Ekert et al., 2020
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single Lgr5 stem cells build crypt-villus structures in vitro without a mesenchymal niche
Sato, T., Vries, R. G., Snippert, H. J., van de Wetering, M., Barker, N., Stange, D. E., van Es, J. H., Abo, A., Kujala, P., Peters, P. J., et al. (2009) · Nature · doi:10.1038/nature07935 · Cited by 7,204
Cerebral organoids model human brain development and microcephaly
Lancaster, M. A., Renner, M., Martin, C.-A., Wenzel, D., Bicknell, L. S., Hurles, M. E., Homfray, T., Penninger, J. M., Jackson, A. P., & Knoblich, J. A. (2013) · Nature · doi:10.1038/nature12517 · Cited by 5,372
Machine Learning Applications in Cancer Prognosis and Prediction
Kourou, K., Exarchos, T. P., Exarchos, K. P., Karamouzis, M. V., & Fotiadis, D. I. (2015) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2014.11.005 · Cited by 3,338
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Genome-Scale CRISPR-Mediated Control of Gene Repression and Activation
Gilbert, L. A., Horlbeck, M. A., Adamson, B., Villalta, J. E., Chen, Y., Whitehead, E. H., Guimaraes, C., Panning, B., Ploegh, H. L., Bassik, M. C., et al. (2014) · Cell · doi:10.1016/j.cell.2014.09.029 · Cited by 2,728
Clinical development success rates for investigational drugs
Hay, M., Thomas, D. W., Craighead, J. L., Economides, C., & Rosenthal, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2786 · Cited by 2,536 · cited 3×
“To achieve this stepwise change, it is time to stop using (1) poorly defined cellular models for target identification, (2) nonrelevant cell-based screening or LO assays with immortalized cell lines, and (3) in vivo models that have shown low predictive value or translational relevance (Fig.”
BackgroundMethodProspective Derivation of a Living Organoid Biobank of Colorectal Cancer Patients
van de Wetering, M., Francies, H. E., Francis, J. M., Bounova, G., Iorio, F., Pronk, A., van Houdt, W., van Gorp, J., Taylor-Weiner, A., Kester, L., et al. (2015) · Cell · doi:10.1016/j.cell.2015.03.053 · Cited by 2,408
Self-citationThe support of human genetic evidence for approved drug indications
Nelson, M. R., Tipney, H., Painter, J. L., Shen, J., Nicoletti, P., Shen, Y., Floratos, A., Sham, P. C., Li, M. J., Wang, J., et al. (2015) · Nature Genetics · doi:10.1038/ng.3314 · Cited by 1,666 · cited 2×
“To achieve this stepwise change, it is time to stop using (1) poorly defined cellular models for target identification, (2) nonrelevant cell-based screening or LO assays with immortalized cell lines, and (3) in vivo models that have shown low predictive value or translational relevance (Fig.”
MethodSchwank, G., Koo, B.-K., Sasselli, V., Dekkers, J. F., Heo, I., Demircan, T., Sasaki, N., Boymans, S., Cuppen, E., van der Ent, C. K., et al. (2013) · Cell Stem Cell · doi:10.1016/j.stem.2013.11.002 · Cited by 1,424
Modeling colorectal cancer using CRISPR-Cas9–mediated engineering of human intestinal organoids
Matano, M., Date, S., Shimokawa, M., Takano, A., Fujii, M., Ohta, Y., Watanabe, T., Kanai, T., & Sato, T. (2015) · Nature Medicine · doi:10.1038/nm.3802 · Cited by 1,135
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology
Ewart, L., Apostolou, A., Briggs, S. A., Carman, C. V., Chaff, J. T., Heng, A. R., Jadalannagari, S., Janardhanan, J., Jang, K.-J., Joshipura, S. R., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00209-1 · Cited by 337
Daly, A. C., Prendergast, M. E., Hughes, A. J., & Burdick, J. A. (2021) · Cell · doi:10.1016/j.cell.2020.12.002 · Cited by 332
Seal, S., Mahale, M., García-Ortegón, M., Joshi, C. K., Hosseini-Gerami, L., Beatson, A., Greenig, M., Shekhar, M., Patra, A., Weis, C., et al. (2025) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.5c00033 · Cited by 187
Predictive validity in drug discovery: what it is, why it matters and how to improve it
Scannell, J. W., Bosley, J., Hickman, J. A., Dawson, G. R., Truebel, H., Ferreira, G. S., Richards, D. B., & Treherne, J. M. (2022) · Nature Reviews Drug Discovery · doi:10.1038/s41573-022-00552-x · Cited by 144
Tosca, E. M., Ronchi, D., Facciolo, D., & Magni, P. (2023) · Biomedicines · doi:10.3390/biomedicines11041058 · Cited by 104
Pamies, D., Ekert, J., Zurich, M.-G., Frey, O., Werner, S., Piergiovanni, M., Freedman, B. S., Keong Teo, A. K., Erfurth, H., Reyes, D. R., et al. (2024) · Stem Cell Reports · doi:10.1016/j.stemcr.2024.03.009 · Cited by 88
Self-citationBassi, G., Grimaudo, M. A., Panseri, S., & Montesi, M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22031195 · Cited by 76
“Therefore, the fundamental question is: “How do we capture the human biological complexity in robust translational in vitro models?” [1].”
BackgroundPre-Clinical In Vitro Models Used in Cancer Research: Results of a Worldwide Survey
Pacheco, S., & O’Driscoll, L. (2021) · Cancers · doi:10.3390/cancers13236033 · Cited by 63
“Thus, there is an urgent need for standardized methods and the establishment of guidelines [27] and/or a transparent knowledge base for the development and characterization of more sophisticated 3D cell culture/co-culture models.”
MethodMicrophysiological Systems: Stakeholder Challenges to Adoption in Drug Development
Hargrove-Grimes, P., Low, L. A., & Tagle, D. A. (2022) · Cells Tissues Organs · doi:10.1159/000517422 · Cited by 48
“Additionally, extinguishing the competitive mindset in pharma, and increasing the amount of data sharing and additional pre-competitive activities, will help promote technological adoption [Ewart and Roth, 2020].”
BackgroundStrong, C. E., Zhang, J., Carrasco, M., Kundu, S., Boutin, M. E., Vishwasrao, H. D., Liu, J., Medina, A., Chen, Y., Wilson, K. M., et al. (2023) · Communications Biology · doi:10.1038/s42003-023-05582-8 · Cited by 55
“…for disease modeling and drug discovery, it is critical to establish their context of use, that is, what stages and mechanisms underlying diseases are reported in a particular assay system, and therefore, what targeted pharmaco-logically agents will perturb the activity of the system 48,49,50 .”
BackgroundFetal bovine serum: how to leave it behind in the pursuit of more reliable science
Weber, T., Malakpour‐Permlid, A., Chary, A., D’Alessandro, V., Haut, L., Seufert, S., Wenzel, E. V., Hickman, J. J., Bieback, K., Wiest, J., et al. (2025) · Frontiers in Toxicology · doi:10.3389/ftox.2025.1612903 · Cited by 53
Using artificial intelligence technology to fight COVID-19: a review
Peng, Y., Liu, E., Peng, S., Chen, Q., Li, D., & Lian, D. (2022) · Artificial Intelligence Review · doi:10.1007/s10462-021-10106-z · Cited by 53
“Ekert et al. (2020) also made a good evaluation on the application of artificial intelligence technology in drug r&d, and he believed that the combination of computational modeling, artificial intelligence, machine learning (AI/ML), and complex in vitro model (CIVM) would increase in the future.”
BackgroundOrgan-on-chip applications in drug discovery: an end user perspective
Clapp, N., Amour, A., Rowan, W. C., & Candarlioglu, P. L. (2021) · Biochemical Society Transactions · doi:10.1042/bst20210840 · Cited by 47
Self-citationIn Vitro Cancer Models: A Closer Look at Limitations on Translation
Antunes, N., Kundu, B., Kundu, S. C., Reis, R. L., & Correlo, V. M. (2022) · Bioengineering · doi:10.3390/bioengineering9040166 · Cited by 46
Artificial Intelligence and Machine Learning for Lead-to-Candidate Decision-Making and Beyond
McNair, D. (2022) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-051921-023255 · Cited by 41
A path forward advancing microphysiological systems
Härtung, T., & Smirnova, L. (2025) · ALTEX · doi:10.14573/altex.2504091 · Cited by 43
“These challenges include rigorous validation of models for specific applications, seamless integration into existing workflows, ensuring cost-effectiveness for routine application, and achieving broad regulatory acceptance and standardization (Ekert et al., 2020).”
Progress in developing microphysiological systems for biological product assessment
Mansouri, M., Lam, J., & Sung, K. E. (2024) · Lab on a Chip · doi:10.1039/d3lc00876b · Cited by 43
Microphysiological systems: What it takes for community adoption
Hargrove-Grimes, P., Low, L. A., & Tagle, D. A. (2021) · Experimental Biology and Medicine · doi:10.1177/15353702211008872 · Cited by 35
“In addition to the need for further MPS characterization, the IQ MPS Affiliate have identified a variety of other hurdles impeding MPS adoption in the pharmaceutical industry including the need for standards, bridging and comparing pre-clinical animal model data with tissue chip data, providing enough data to increase…”
MethodTomlinson, L., Ramsden, D., Leite, S. B., Beken, S., Bonzo, J. A., Brown, P., Candarlioglu, P. L., Chan, T. S., Chen, E., Choi, C. K., et al. (2024) · Advanced Biology · doi:10.1002/adbi.202300131 · Cited by 33
Self-citationSchofield, C. A., Walker, T. M., Taylor, M. A., Patel, M., Vlachou, D. F., Macina, J. M., Vidgeon-Hart, M., Williams, A., McGill, P., Newman, C. F., et al. (2021) · Chemical Research in Toxicology · doi:10.1021/acs.chemrestox.1c00227 · Cited by 31
Self-citationCastellino, S., Lareau, N. M., & Groseclose, M. R. (2021) · Journal of Mass Spectrometry · doi:10.1002/jms.4717 · Cited by 29
“Using scaffolds, hydrogels, and microfabricated devices, 3D cell culture technology has rapidly developed as a promising assay for testing of drug delivery, metabolism, pharmacology, and toxicity.(16) MALDI IMS has the potential to be a key part of the analytical strategy for assessing 3D cell cultures by measuring dr…”
BackgroundImpact of mechanical cues on key cell functions and cell-nanoparticle interactions
Elblová, P., Lunová, M., Dejneka, A., Jirsa, M., & Lunov, O. (2024) · Discover Nano · doi:10.1186/s11671-024-04052-2 · Cited by 28
In-silico Approaches for Drug Designing Technology: Bridging Discovery and Development
Islam, A., Jena, D., Mondal, N. S., Teli, A., Mondal, S., & Gautam, M. K. (2025) · Current Drug Discovery Technologies · doi:10.2174/0115701638326869250207060616 · Cited by 25
Miedel, M. T., Varmazyad, M., Xia, M., Brooks, M. M., Gavlock, D. C., Reese, C. E., Behari, J., Soto–Gutiérrez, A., Gough, A., Taylor, D. L., et al. (2025) · Cell Reports Methods · doi:10.1016/j.crmeth.2025.101028 · Cited by 24
“11,12 The US Food and Drug Administration (FDA) removed the requirement of animal testing for drug candidates as part of the FDA Modernization Act 2.0.”
InfluentialMicrofluidic technologies for ex vivo tissue biopsies: A review
Garcia-Garcia, F. C., Candarlioglu, P. L., Porter, J. D., Davies, D. E., Swindle, E. J., & Morgan, H. (2022) · Organs-on-a-Chip · doi:10.1016/j.ooc.2022.100020 · Cited by 23
Gaebler, D., Hachey, S. J., & Hughes, C. C. W. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1462293 · Cited by 22
Bridging the gap: From petri dish to patient - Advancements in translational drug discovery
El‐Tanani, M., Rabbani, S. A., El‐Tanani, Y., Matalka, I. I., & Khalil, I. A. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e41317 · Cited by 20
Abdelkarim, M., Pérez-Dávalos, L. A., Abdelkader, Y., Abostait, A., & Labouta, H. I. (2022) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2023.2152000 · Cited by 20
Advances and applications of organ-on-a-chip technology
Kong, J. S., Kim, J., Jang, J., & Cho, D.-W. (2026) · Cell Reports Methods · doi:10.1016/j.crmeth.2026.101361 · Cited by 20
Generation and Culture of Lingual Organoids Derived from Adult Mouse Taste Stem Cells
Shechtman, L. A., Piarowski, C. M., Scott, J. K., Golden, E., Gaillard, D., & Barlow, L. A. (2021) · Journal of Visualized Experiments · doi:10.3791/62300 · Cited by 18
Reyaz, A., Qadri, S. S., Javaid, D., Ganie, S. Y., & Reshi, M. S. (2025) · Phytomedicine Plus · doi:10.1016/j.phyplu.2025.100845 · Cited by 17
Jung, O., Song, M. J., & Ferrer, M. (2021) · SLAS DISCOVERY · doi:10.1177/24725552211030903 · Cited by 17
“, design of vascularization patterns to better quantitate vasculogenesis and angiogenesis), (5) shorter time to assay readouts unlike organoid systems because of the use of differentiated cells, (6) higher reproducibility due to the automation process used in bioprinting, and (7) compatibility with medium-throughput a…”
Opportunities and challenges for human microphysiological systems in drug development
Rahman, S. M., Krishna, A., Sullenberger, C., Jeong, Y. E., García, M., Bhardwaj, B., Geiger, R. M., Blinova, K., & Ford, K. A. (2024) · ALTEX · doi:10.14573/altex.2409221 · Cited by 17
“Some publications have additionally elaborated on how these data sets may be integrated into the regulatory process (Ekert et al., 2020; Haddrick and Simpson, 2019; Hargrove-Grimes et al., 2022; Levner and Ewart, 2023).”
Organ‐on‐a‐Chip Technology and Global Multi‐Omics: Current Applications and Future Directions
Cao, X., Xia, C., Li, C., Deng, S., Cao, J., Yang, H., Wang, S., & Chen, P. (2026) · MedComm · doi:10.1002/mco2.70603 · Cited by 14
“Disparities in cell sources (such as primary cells, cell lines, or iPSC-derived cells) and batch-to-batch variability significantly impact the stability and reliability of the models [ 150 ].”
Beyond the hype and toward application: liver complex in vitro models in preclinical drug safety
Jadalannagari, S., & Ewart, L. C. (2024) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2024.2328794 · Cited by 15
“…working with an assortment of materials and cell types, the CIVM landscape has become challenging for end-users to identify the best tool for their needs, with some reporting a gap between development, reproducibility, standardization, and qualification of these in vitro models [20,21,58,59].”
Silvestri, A., Vicente, F., Vicent, M. J., Stechmann, B., & Fecke, W. (2021) · Drug Discovery Today · doi:10.1016/j.drudis.2021.02.024 · Cited by 14
Stokar‐Regenscheit, N., Bell, L., Berridge, B. R., Rudmann, D. G., Tagle, D. A., Hargrove-Grimes, P., Schaudien, D., Hahn, K., Kuehnlenz, J., Ashton, R. S., et al. (2024) · Toxicologic Pathology · doi:10.1177/01926233241253811 · Cited by 14
“Thus, pathologists have a significant collaborative role to play in supporting the development and application of these novel systems, which often use reductionism principles to model biology in a scalable format 11,59,67 (Figure 1).”
Three-Dimensional Spheroids for Cancer Research
Tutty, M. A., & Prina‐Mello, A. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3056-3_3 · Cited by 13
Cadavid, J. L., Li, N. T., & McGuigan, A. P. (2024) · Biophysics Reviews · doi:10.1063/5.0179125 · Cited by 12
Taylor, K., Ram, R., Ewart, L. C., Goldring, C. E., Russomanno, G., Aithal, G. P., Kostrzewski, T. M., Bauch, C., Wilkinson, J. M., Modi, S., et al. (2025) · Frontiers in Drug Discovery · doi:10.3389/fddsv.2025.1536756 · Cited by 12
Ellison, S. T., Hayman, I., Derr, K., Derr, P., Frebert, S., Itkin, Z., Shen, M., Jones, A., Olson, W., Corey, L., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-64245-w · Cited by 12
Advancing preclinical research with reconstructed in vitro skin models mimicking non-healing wounds
Daré, R. G., Lopes, L. B., Petri‐Fink, A., & Rothen‐Rutishauser, B. (2026) · International Journal of Pharmaceutics X · doi:10.1016/j.ijpx.2026.100518 · Cited by 12
An overview of artificial intelligence in drug development
Philip, A. K., & Faiyazuddin, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-89925-3.00001-0 · Cited by 11
Weener, H. J., Middelkamp, H. H. T., & Van der Meer, A. D. (2024) · Frontiers in Toxicology · doi:10.3389/ftox.2024.1513002 · Cited by 10
Barua, R., Das, D., & Biswas, N. (2025) · Biomicrofluidics · doi:10.1063/5.0268362 · Cited by 10
The Cancer Moonshot, the role of in vitro models, model accuracy, and the need for validation
Searson, P. C. (2023) · Nature Nanotechnology · doi:10.1038/s41565-023-01486-0 · Cited by 10
Report of the Assay Guidance Workshop on 3-Dimensional Tissue Models for Antiviral Drug Development
Jordan, R., Ford‐Scheimer, S. L., Alarcon, R. M., Atala, A., Borenstein, J. T., Brimacombe, K. R., Cherry, S. R., Clevers, H. C., Davis, M. I., Funnell, S. G. P., et al. (2023) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiad334 · Cited by 9
Calabretta, M. M., & Michelini, E. (2023) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2023.2266989 · Cited by 9
“The integration of BL proteins, 3D cell models, and miniaturized platforms represents a promising approach, which could provide sustainable and cost-effective organ-on-a-chip platforms not only for predictive drug screening but also for drug development and precision medicine applications [103,104].”
BackgroundPrabhu, N., Rajinikanth, V., & Narayanan, M. (2026) · Molecular Biology Reports · doi:10.1007/s11033-025-11421-2 · Cited by 8
“…of microfluidics-based high-throughput T cell activation assays, in vivo humanized mouse models, and customized APC platforms may offer scalable and accelerated alternatives to traditional valida - tion techniques, thereby bridging the gap between discovery and clinical application [ 39].”
Advances in antibacterial agents for Mycobacterium fortuitum
Jortieke, C. R. T., Joaquim, A. R., & Fumagalli, F. (2025) · RSC Medicinal Chemistry · doi:10.1039/d4md00508b · Cited by 8
Kearney, H., Mihaila, S. M., Moroni, L., & Mota, C. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202504719 · Cited by 7
Majer, J., Alex, A., Shi, J., Chaney, E. J., Mukherjee, P., Spillman, D. R., Marjanović, M., Newman, C. F., Groseclose, R. M., Watson, P., et al. (2024) · Lab on a Chip · doi:10.1039/d4lc00504j · Cited by 7
From concept to context-of-use: A framework for Organ-on-Chip development
Araújo‐Gomes, N., Middelkamp, H. H. T., Loessberg-Zahl, J., Raaij, J. V. D. E., van der Meer, A. D., & Middendorp, S. (2026) · NAM journal. · doi:10.1016/j.namjnl.2026.100097 · Cited by 4
Towards learning and memory risk assessment with human brain organoids: barriers and opportunities
Mohapatra, R., Din, D. A. E., Zhao, H., Härtung, T., & Smirnova, L. (2026) · Frontiers in Toxicology · doi:10.3389/ftox.2026.1783893 · Cited by 3
“Quality assurance frameworks for MPS, including hBOs, are emerging based on established in vitro standards (Ekert et al., 2020; Pamies et al., 2022; 2024).”
Chaput, S., Driouich, J., Gruber, S., Busler, D., de Lamballerie, X. N., Nougaırède, A., & Touret, F. (2025) · Antiviral Research · doi:10.1016/j.antiviral.2025.106188 · Cited by 3
3D-bioprinted in vitro disease models
Maia, F. R., Reis, R. L., & Oliveira, J. M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-89831-7.00004-3 · Cited by 4
Reardon, E. C., Greaney, A. J., & Mulvihill, J. J. (2025) · Fluids and Barriers of the CNS · doi:10.1186/s12987-025-00715-z · Cited by 2
“Such an in vitro model would allow for drug screening of potential therapeutics in more personalised and humanised models [35, 120].”
Chaput, S., Nougaırède, A., & Touret, F. (2026) · Viruses · doi:10.3390/v18030386 · Cited by 2
Fontoura, M. B., & Fumagalli, F. (2022) · Letters in Drug Design & Discovery · doi:10.2174/1570180819666220928151734 · Cited by 2
Application of microphysiological systems for nonclinical evaluation of cell therapies
Candarlioglu, P. L., Delsing, L., Gauthier, L. M., Lewis, L. S., Papadopoulos, G., Freag, M. S., Chan, T. S., Homan, K. A., Fellows, M. D., Pointon, A., et al. (2024) · ALTEX · doi:10.14573/altex.2402201 · Cited by 3
“Additionally, there are published guidelines from industry leaders (Ekert et al., 2020), regulators (Piergiovanni et al., 2021a,b, 2024) and consortia of stakeholders (Parvatam et al., 2024; Pamies et al., 2024; Reyes et al., 2024) that delve deeply into the concept of standardization,…”
BackgroundStudying Endothelial Permeability In Vitro for Diabetic Kidney Disease Research
Telle, V. (2024) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.910532218 · Cited by 2
Canhão, P. G. M., Smeuninx, A., Geerinckx, S., Evers, R., Snoeys, J., Augustijns, P., & Kourula, S. (2026) · Toxicology in Vitro · doi:10.1016/j.tiv.2026.106221 · Cited by 1
Muscle-Nerve-Immune Crosschats: Troika Theorization
Dutta, D. (2026) · Physiology · doi:10.5772/intechopen.1014066 · Cited by 1
Controlling the Third Dimension
Eilenberger, C. (2021) · reposiTUm (TU Wien) · doi:10.34726/hss.2021.50560
(2026) · Nuclear Medicine Seminars · doi:10.4274/nts
Marx, U., Beken, S., Chen, Z., Dehne, E.-M., Doherty, A., Ewart, L., Fitzpatrick, S. C., Griffith, L. G., Gu, Z., Hartung, T., et al. (2025) · ALTEX · doi:10.14573/altex.2410112s
The Future of Computer-aided Drug Design
Persilioglu, E. (2025) · Bidge Yayınları eBooks · doi:10.70269/10.70269/1429253118
Research progress of organoid technology applied to nonhuman primates
He, S., Sun, X., Long, E., Lu, Z., & Zhou, L. (2025) · Scientia Sinica Vitae · doi:10.1360/ssv-2024-0263
Differences between in vivo and ex vivo models drive divergent perturbation outcomesPreprint
Geetha, A. R. S. J., del Valle, C., Esser‐Skala, W., Lara‐Astiaso, D., & Fortelny, N. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.09.02.673692
Utilising human cellular models of Primary Ciliary Dyskinesia: A scoping review
Ong, J., Tsang, W., Lucas, J. S., Jackson, C. L., & Rubbo, B. (2025) · European Respiratory Review · doi:10.1183/13993003.congress-2025.pa5912
Advanced 3D Bioprinted Tissue Models: Revolutionizing Research, Drug Discovery, and Toxicology
Sagar, M. S. I., Hossain, M. A., Sheikh, K., & Hossain, K. R. (2025) · Journal of Kufa for Chemical Sciences · doi:10.36329/jkcm/2025/v5.i1.17287
Computational strategies for the discovery of small molecule therapeutics against SARS-CoV-2 virus
Mslati, H. (2023) · cIRcle (University of British Columbia) · doi:10.14288/1.0427272
Majer, J. (2023) · ORCA Online Research @Cardiff (Cardiff University)
Wu, C.-H., Qiu, J.-X., Jia, Y.-B., 权毅, Liu, C., & Ling, J. (2026) · WArtificial Intelligence in Cancer · doi:10.35713/aic.v7.i1.114273
Tong, Z., Yang, S., Chen, J., Guo, H., Zhao, P., & Wu, H. (2026) · Materials Today Bio · doi:10.1016/j.mtbio.2026.103790
Kurtenbach, P., Hahn, M., Thevis, M., & Lamshoeft, M. (2026) · NAM journal. · doi:10.1016/j.namjnl.2026.100142
“For regulatory application, the challenge is to identify model formats that combine physiological relevance with standardization, reproducibility and scalability (Ekert et al., 2020).”
Beyond biomimicry: Mechanobiological qualification of human-relevant NAMs
Lee, N., & Kim, H. S. (2026) · Mechanobiology · doi:10.1177/29780241261499231
Metadata
- Authors
- Ekert, J. E., Deakyne, J., Pribul-Allen, P., Terry, R., Schofield, C., Jeong, C. G., Storey, J., Mohamet, L., Francis, J., Naidoo, A., Amador, A., Klein, J.-L., & Rowan, W.
- Affiliations
- GlaxoSmithKline (United States) (US)
- GlaxoSmithKline (United Kingdom) (GB)
- insitro, inc. (United States) (US)
- Corresponding author
- Ekert, Jason E.
- Venue
- SLAS DISCOVERY
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 25
- Issue
- 10
- Pages
- 1174-1190
- ISSN
- 2472-5552 (ISSN-L)
- OpenAlex
- W3030677830
- Cited by
- 68
- References
- 89
- Citations by year
- 2026: 12 · 2025: 14 · 2024: 12 · 2023: 9 · 2022: 9 · 2021: 12
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 476 d)
- Locations
- SLAS DISCOVERY (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Drug Discovery › Computational Drug Discovery Methods
- Keywords
- early drug discovery, model qualification, organoids, spheroids, microphysiological systems, bioprinting, stem cells, primary cells, lead optimization, preclinical safety, target identification and validation, computational modeling, artificial intelligence in drug discovery, translational research
- MeSH terms
- Machine Learning, Drug Development, Animals, Artificial Intelligence, Automation, Drug Evaluation, Preclinical, Humans, Models, Molecular, Research, Guidelines as Topic, Drug Discovery, High-Throughput Screening Assays, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.