The DOI matches its Crossref record.
Method for analysis of cellular DNA content of paraffin-embedded pathological material using flow cytometry.
Abstract
A method has been developed that allows flow cytometry to be used for measuring the cellular DNA content of paraffin-embedded human tumors. Thick (i.e., 30 micron) sections were cut from tissue blocks using a microtome and dewaxed in xylene. The sections were then rehydrated by sequentially immersing them in 100, 95, 70, and 50% ethanol before finally washing in distilled water. Single cell suspensions were then prepared by incubation in 0.5% pepsin, pH 1.5, at 37 degrees C for 30 min. The cells were counted, washed, and stained with 1 microgram/ml 4',6'-diamidino-2-phenylindole for 30 min, and DNA content was measured using an ICP 22 flow cytometer. There was a good correlation between the DNA histograms produced using this method and those obtained using unfixed tissue from the same tumor stained with ethidium bromide plus mithramycin. This method allows the retrospective study of archival material where the clinical outcome is already known, and it should, therefore, be particularly useful for determining the prognostic significance of abnormal DNA content measured by flow cytometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zava, D. T., & Duwe, G. (1997) · Nutrition and Cancer · doi:10.1080/01635589709514498 · Cited by 462
Single-Nucleus RNA-Seq: Open the Era of Great Navigation for FFPE Tissue
Guo, Y., Wang, W., Ye, K., He, L., Ge, Q., Huang, Y., & Zhao, X. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241813744 · Cited by 27
Malignant tumors arising in endometriosis: Clinical-pathological study and flow cytometry analysis
Fishman, A., Demirel, D., Laucirica, R., Ramzy, I., Klima, T., Lyzak, J., & Kaplan, A. L. (1996) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(96)02563-8 · Cited by 23
Metadata
- Authors
- Hedley, D. W., Friedlander, M. L., Taylor, I. W., Rugg, C. A., & Musgrove, E. A.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 1983-11
- Volume
- 31
- Issue
- 11
- Pages
- 1333-1335
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2018708063
- Cited by
- 2,031
- References
- 0
- FWCI
- 17.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Method for analysis of cellular DNA content of paraffin-embedded pathological material using flow cytometry. https://app.cochat.ai/papers/10.1177/31.11.6619538
- The paper
- Hedley, D. W., Friedlander, M. L., Taylor, I. W., Rugg, C. A., & Musgrove, E. A. (1983). Method for analysis of cellular DNA content of paraffin-embedded pathological material using flow cytometry. Journal of Histochemistry & Cytochemistry. https://doi.org/10.1177/31.11.6619538
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.