Risk of Chromosomal Abnormalities in Patients with Idiopathic Polyhydramnios
The DOI matches its Crossref record.
Abstract
This prospective investigation was designed to assess the incidence of chromosomal abnormalities in patients with idiopathic polyhydramnios. Polyhydramnios was defined as 25 cm or greater in total vertical height in all four quadrants (amniotic fluid index) in any nonreferral patient (ie, primary care population) undergoing sonographic examination with a singleton pregnancy, normal fetal anatomical survey, normal glucose screening, and negative antibody screen. During the 2-year period from May 1, 1988 through April 30, 1990, 5038 gravidas delivered at Madigan Army Hospital Center. Unexplained polyhydramnios was detected sonographically in 125 patients, an incidence of 2.5%. After obtaining informed written consent, amniocentesis was performed in all patients. Within this group (N = 125), four chromosomal abnormalities (incidence of 3.2%) were detected. There were two trisomy 18 and two trisomy 21 fetuses. None of the four patients had maternal serum alpha-fetoprotein screening performed. The incidence of aneuploidy in patients with idiopathic polyhydramnios (3.2%) is much higher than the reported incidence of major karyotype abnormalities in live births (0.59%). We conclude that fetal chromosomal analysis should be considered in all obstetric patients with sonographic evidence of idiopathic polyhydramnios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chauhan, S. P., Sanderson, M., Hendrix, N. W., Magann, E. F., & Devoe, L. D. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70393-5 · Cited by 279
The amniotic fluid index, single deepest pocket, and two-diameter pocket in normal human pregnancy
Magann, E. F., Sanderson, M., Martin, J. N., & Chauhan, S. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2000.107325 · Cited by 204
A Review of Idiopathic Hydramnios and Pregnancy Outcomes
Magann, E. F., Chauhan, S. P., Doherty, D. A., Lutgendorf, M. A., Magann, M. I., & Morrison, J. C. (2007) · Obstetrical & Gynecological Survey · doi:10.1097/01.ogx.0000290349.58707.e0 · Cited by 174
Hydramnios: anomaly prevalence and sonographic detection
Dashe, J. (2002) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(02)02013-6 · Cited by 142
Maximal amniotic fluid index as a prognostic factor in pregnancies complicated by polyhydramnios
Pri‐Paz, S., Khalek, N., Fuchs, K. M., & Simpson, L. L. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10093 · Cited by 96
Metadata
- Venue
- Journal of Diagnostic Medical Sonography
- Publisher
- SAGE Publications
- Published
- 1992-05
- Volume
- 8
- Issue
- 3
- Pages
- 165-165
- ISSN
- 1552-5430 (ISSN-L)
- 8756-4793
- OpenAlex
- W148919871
- Cited by
- 58
- References
- 0
- FWCI
- 1.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Risk of Chromosomal Abnormalities in Patients with Idiopathic Polyhydramnios. https://app.cochat.ai/papers/10.1177/875647939200800338
- The paper
- Risk of Chromosomal Abnormalities in Patients with Idiopathic Polyhydramnios. (1992). Journal of Diagnostic Medical Sonography. https://doi.org/10.1177/875647939200800338
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.