A comparison of plaster, digital and reconstructed study model accuracy
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To evaluate the accuracy and reproducibility of a three-dimensional (3D) optical laser-scanning device to record the surface detail of plaster study models. To determine the accuracy of physical model replicas constructed from the 3D digital files. DESIGN AND SETTING: A method comparison study using 30 dental study models held in the Orthodontic Department, School of Dentistry, Cardiff University. MATERIALS AND METHODS: Each model was captured three-dimensionally, using a commercially available Minolta VIVID 900 non-contact 3D surface laser scanner (Konica Minolta Inc., Tokyo, Japan), a rotary stage and Easy3DScan integrating software (TowerGraphics, Lucca, Italy). Linear measurements were recorded between landmarks, directly on each of the plaster models and indirectly on the 3D digital surface models, on two separate occasions by a single examiner. Physical replicas of two digital models were also reconstructed from their scanned data files, using a rapid prototyping (RP) manufacturing process, and directly evaluated for dimensional accuracy. RESULTS: The mean difference between measurements made directly on the plaster models and those made on the 3D digital surface models was 0.14 mm, and was not statistically significant (P = 0.237). The mean difference between measurements made on both the plaster and virtual models and those on the RP models, in the z plane was highly statistically significant (P <0.001). CONCLUSIONS: The Minolta VIVID 900 digitizer is a reliable device for capturing the surface detail of plaster study models three-dimensionally in a digital format but physical models of appropriate detail and accuracy cannot be reproduced from scanned data using the RP technique described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research.
Walter, S. D., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,668 · cited 1×
“90).(25) Thirty randomly selected plaster study models, held in the Orthodontic Unit of University Dental Hospital, Cardiff, were used in the study.”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Stevens, D. R., Flores‐Mir, C., Nebbe, B., Raboud, D. W., Heo, G., & Major, P. W. (2006) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2004.08.023 · Cited by 389 · cited 2×
“The excellent reproducibility of plaster, digital and reconstructed model measurements reported compares favourably with Zilberman et al.20 and Bell et al.28 who reported mean intra-operator errors of 0.18 and 0.17 mm respectively, when the same points were measured by the same operator at different times on plaster s…”
BackgroundInfluentialThe accuracy and reliability of measurements made on computer-based digital models.
Quimby, M. L., Vig, K. W. L., Rashid, R., & Firestone, A. R. (2004) · PubMed · doi:10.1043/0003-3219(2004)074<0298:taarom>2.0.co;2 · Cited by 374
Reliability of a 3D surface laser scanner for orthodontic applications
Kusnoto, B., & Evans, C. A. (2002) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1067/mod.2002.128219 · Cited by 215
Complete 3-D reconstruction of dental cast shape using perceptual grouping
Hirogaki, Y., Sohmura, T., Satoh, H., et al. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959306 · Cited by 125 · cited 2×
“Hirogaki et al.(11) suggested the accuracy required with orthodontic study models to be about 0.”
BackgroundInfluentialFacial prosthetic model fabrication using rapid prototyping tools
Kai, C. C., Meng, C. S., Lin, S. C., Lee, S.-T., & Aung, S. C. (2000) · Integrated Manufacturing Systems · doi:10.1108/09576060010303668 · Cited by 62 · cited 1×
“Rapid prototyping (RP) systems, such as stereolithography, generate 3D models from a digital file through incremental layering of photo-curable polymers.(21) The dimensional accuracy of physical replicas reproduced using the stereolithography technique has been evaluated Journal of Orthodontics, Vol.”
Method
Cited by
Advancements in CAD/CAM technology: Options for practical implementation
Alghazzawi, T. F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.01.003 · Cited by 637
Current and emerging applications of 3D printing in medicine
Liaw, C.-Y., & Guvendiren, M. (2017) · Biofabrication · doi:10.1088/1758-5090/aa7279 · Cited by 604
Orthodontic measurements on digital study models compared with plaster models: a systematic review
Fleming, P., Marinho, V, & Johal, A. (2011) · Orthodontics & Craniofacial Research · doi:10.1111/j.1601-6343.2010.01503.x · Cited by 409
Hazeveld, A., Huddleston Slater, J. J. R., & Ren, Y. (2014) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.05.011 · Cited by 357
Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review
Etemad-Shahidi, Y., Qallandar, O. B., Evenden, J., Alifui-Segbaya, F., & Ahmed, K. E. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9103357 · Cited by 206
“In addition, there were four studies [4,35,47,54] that did not include a reference model as a control, rather compared various printing technologies against each other.”
BackgroundMethodResultInfluential
Metadata
- Authors
- Keating, A. P., Knox, J., Bibb, R., & Zhurov, A. I.
- Venue
- Journal of Orthodontics
- Publisher
- Informa UK Limited
- Published
- 2008-09
- Volume
- 35
- Issue
- 3
- Pages
- 191-201
- ISSN
- 1465-3125 (ISSN-L)
- 1465-3133
- OpenAlex
- W2024153804
- Cited by
- 225
- References
- 8
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.