Cited by 34High-Temperature Coating BehaviorsHigh Temperature Alloys and CreepSurface Treatment and Coatings

Evaluation of hot corrosion behaviour of HVOF sprayed Ni–5Al and NiCrAl coatings in coal fired boiler environment

Mahesh, R. A., Jayaganthan, R., Prakash, S.·2010·Surface Engineering

Abstract

Hot corrosion was recognised as a serious problem in connection with the degradation of fireside boiler tubes in coal fired steam generating plants. It is one of the most deleterious forms of surface degradation which can lead to the loss of mechanical strength and catastrophic failure of structural and engineering components. In the present investigation, an attempt has been made to evaluate the hot corrosion behaviour of high velocity oxyfuel (HVOF) sprayed Ni–5Al and NiCrAl coatings on iron based superalloy in an actual coal fired boiler environment. The coated specimens were hung in the low temperature superheater zone (∼700°C) of a coal fired boiler. The studies were carried out for 10 cycles each cycle consisting of exposing the coated specimens for 100 h followed by 1 h cooling to ambient conditions. NiCrAl coated specimen provided better resistance to hot corrosion than Ni–5Al coated specimen in the given environment.

Integrity signals

Registry

Crossref · 10.1179/174329409x451164

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Aluminium in nickel-based HVOF coatings produces a protective layer of Al2O3 against corrosion attacks in both laboratory-scale and boiler environments.

    “Alloying element such as aluminium in nickel-based HVOF coatings also produces a protective layer of Al2O3 against corrosion attacks in both laboratory-scale and boiler environments [91, 104].”

Cited by

Sorted by citations

Authors
Mahesh, R. A., Jayaganthan, R., & Prakash, S.
Affiliations
Indian Institute of Technology Roorkee (IN)
Venue
Surface Engineering
Published
2010-08
Volume
26
Issue
6
Pages
413-421
ISSN
  • 0267-0844 (ISSN-L)
  • 1743-2944
OpenAlex
W1981726556
Cited by
34
References
0
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2022: 4 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 2 · 2017: 4 · 2016: 2 · 2015: 3 · 2014: 4 · 2013: 1 · 2012: 2
FWCI
1.94
Type
journal article
Language
en
Open access
closed
Locations
Surface Engineering (publishedVersion)
Topics
  • Physical Sciences › Engineering › Aerospace Engineering › High-Temperature Coating Behaviors
  • Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
  • Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
Keywords
hot corrosion, HVOF spraying, coal-fired boilers, superheater tubes, iron-based superalloys, protective coatings, fireside corrosion

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review