Cited by 11Hearing Loss and RehabilitationHearing, Cochlea, Tinnitus, GeneticsHearing Impairment and Communication

The relationship between electrical auditory brainstem responses and perceptual thresholds in Digisonic®SP cochlear implant users

Guenser, Geoffrey, Laudanski, Jonathan, Phillipon, Bertrand, Backus, Bradford C, Bordure, Philippe, Romanet, Philippe, Parietti-Winkler, Cécile·2015·Cochlear Implants International

Abstract

Determining the electrical stimulation levels is often a difficult and time-consuming task because they are normally determined behaviorally - a particular challenge when dealing with pediatric patients. The evoked stapedius reflex threshold and the evoked compound action potential have already been shown to provide reasonable estimates of the C- and T-levels, although these estimates tend to overestimate the C- and T-levels. The aim of this study was to investigate whether the evoked auditory brainstem response (eABR) can also be used to reliably estimate a patient's C- and T-levels. The correlation between eABR detection thresholds and behaviorally measured perceptual thresholds was statistically significant (r = 0.71; P < 0.001). In addition, eABR Wave-V amplitude increased with increasing stimulation level for the three loudness levels tested. These results show that the eABR detection threshold can be used to estimate a patient's T-levels. In addition, Wave-V amplitude could provide a method for estimating C-levels in the future. The eABR objective measure may provide a useful cochlear implant fitting method - particularly for pediatric patients.

Integrity signals

Registry

Crossref · 10.1179/1754762814y.0000000082

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other measures like ECAP, EABR, and CAEPs have been studied to automatically fit cochlear implants, but none of them reached a clinical application.

    “Other measures like ECAP (McKay et al., 2013), electrically evocated auditory brainstem response (EABR) (Guenser et al., 2015), cortical auditory evoked potentials (CAEPs) (Visram et al., 2015) have been studied to automatically fit cochlear implants, but none of them reached a clinical application.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Guenser, G., Laudanski, J., Phillipon, B., Backus, B. C., Bordure, P., Romanet, P., & Parietti-Winkler, C.
Affiliations
  • Oticon Medical (Sweden) (SE)
  • Centre Hospitalier Universitaire de Nantes (FR)
  • CHU Dijon Bourgogne (FR)
Corresponding author
Guenser, Geoffrey
Venue
Cochlear Implants International
Published
2014-05-25
Volume
16
Issue
1
Pages
32-38
ISSN
  • 1467-0100 (ISSN-L)
  • 1754-7628
OpenAlex
W2078833502
Cited by
11
References
34
Citations by year
2025: 2 · 2022: 3 · 2021: 3 · 2020: 1 · 2017: 2
FWCI
0.37
Type
journal article
Language
en
Open access
closed
Locations
  • Cochlear Implants International (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Hearing Loss and Rehabilitation
  • Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
  • Social Sciences › Psychology › Developmental and Educational Psychology › Hearing Impairment and Communication
Keywords
cochlear implant fitting, T Levels, perceptual thresholds, pediatric cochlear implant users
MeSH terms
Action Potentials, Adult, Auditory Threshold, Cochlear Implants, Electric Stimulation, Female, Humans, Loudness Perception, Male, Middle Aged, Stapedius, Evoked Potentials, Auditory, Brain Stem, Cochlear Implantation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review