Atomic number and crystallographic contrast images with the SEM: a review of backscattered electron techniques
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Backscattered electrons (BSE) are incident electrons reflected back from a target specimen and imaged with the scanning electron microscope (SEM). Three distinct BSE signals exist: atomic number or Z-contrast, in which composition determines image contrast; orientation contrast, in which specimen crystal structure determines image contrast; and electron channelling patterns (ECP), which are unique for a particular crystal orientation. The origins of these three signals are described, with particular attention being given to the necessary SEM operational and specimen preparation requirements. Z-contrast images are relatively simple to obtain and also have a familiar appearance such that their usage should become commonplace. ECP in comparison require subsequent interpretation which depends on the crystal structure and the relationship between crystal and specimen coordinate systems. A general solution to ECP interpretation is therefore presented, involving the construction of reference ‘ECP-maps’ over the surface of a sphere. A brief summary of the applications and potential use of the three BSE signals in the geological sciences is also given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scanning Electron Microscopy and X-Ray Microanalysis
Goldstein, J. I., Newbury, D. E., Michael, J. R., Ritchie, N. W. M., Scott, J. H. J., & Joy, D. C. (2018) · Springer eBooks · doi:10.1007/978-1-4939-6676-9 · Cited by 5,361
Scanning Electron Microscopy and X-Ray Microanalysis
Goldstein, J. I., Newbury, D. E., Echlin, P., Joy, D. C., Fiori, C., & Lifshin, E. (1981) · Springer eBooks · doi:10.1007/978-1-4613-3273-2 · Cited by 1,010
Practical Scanning Electron Microscopy: Electron and Ion Microprobe Analysis
Goldstein, J. I., & Yakowitz, H. (1975) · Springer eBooks · doi:10.1007/978-1-4613-4422-3 · Cited by 581
Quantitative Scanning Electron Microscopy
Maugel, T. K., Holt, D. B., Muir, M. D., Grant, P. R., & Boswarva, I. M. (1976) · Transactions of the American Microscopical Society · doi:10.2307/3225074 · Cited by 290
On the production of X-rays in thin metal foils
Hirsch, P. B., Howie, A., & Whelan, M. J. (1962) · Philosophical magazine · doi:10.1080/14786436208214478 · Cited by 94
Deformation of chromite: S.E.M. investigations
Christiansen, F. G. (1986) · Tectonophysics · doi:10.1016/0040-1951(86)90042-9 · Cited by 19
Cited by
Bultreys, T., De Boever, W., & Cnudde, V. (2016) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.02.001 · Cited by 474
A practical guide to rock microstructure
(2005) · Choice Reviews Online · doi:10.5860/choice.42-4665 · Cited by 471
Roschger, P., Fratzl, P., Eschberger, J., & Klaushofer, K. (1998) · Bone · doi:10.1016/s8756-3282(98)00112-4 · Cited by 456
Effect of water and stress on the lattice-preferred orientation of olivine
Jung, H., Katayama, I., Jiang, Z., Hiraga, T., & Karato, S. (2006) · Tectonophysics · doi:10.1016/j.tecto.2006.02.011 · Cited by 400
Hayman, A. R., Jones, S. J., Boyde, A., Foster, D., Colledge, W. H., Carlton, M. B., Evans, M. J., & Cox, T. M. (1996) · Development · doi:10.1242/dev.122.10.3151 · Cited by 372
Metadata
- Authors
- Lloyd, G. E.
- Venue
- Mineralogical Magazine
- Publisher
- Mineralogical Society
- Published
- 1987-03
- Volume
- 51
- Issue
- 359
- Pages
- 3-19
- ISSN
- 0026-461X (ISSN-L)
- 1471-8022
- OpenAlex
- W2054360246
- Cited by
- 543
- References
- 6
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.