The DOI matches its Crossref record.
Mechanism of platelet adhesion to von Willebrand factor and microparticle formation under high shear stress
Open accessAbstract
We describe here the mechanism of platelet adhesion to immobilized von Willebrand factor (VWF) and subsequent formation of platelet-derived microparticles mediated by glycoprotein Ibalpha (GPIbalpha) under high shear stress. As visualized in whole blood perfused in a flow chamber, platelet attachment to VWF involved one or few membrane areas of 0.05 to 0.1 microm(2) that formed discrete adhesion points (DAPs) capable of resisting force in excess of 160 pN. Under the influence of hydrodynamic drag, membrane tethers developed between the moving platelet body and DAPs firmly adherent to immobilized VWF. Continued stretching eventually caused the separation of many such tethers, leaving on the surface tube-shaped or spherical microparticles with a diameter as low as 50 to 100 nm. Adhesion receptors (GPIbalpha, alphaIIbbeta3) and phosphatidylserine were expressed on the surface of these microparticles, which were procoagulant. Shearing platelet-rich plasma at the rate of 10,000 s(-1) in a cone-and-plate viscosimeter increased microparticle counts up to 55-fold above baseline. Blocking the GPIb-VWF interaction abolished microparticle generation in both experimental conditions. Thus, a biomechanical process mediated by GPIbalpha-VWF bonds in rapidly flowing blood may not only initiate platelet arrest onto reactive vascular surfaces but also generate procoagulant microparticles that further enhance thrombus formation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Arraud, N., Linares, R., Tan, S., Gounou, C., Pasquet, J. ‐., Mornet, S., & Brisson, A. R. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12554 · Cited by 740
Cell-derived microparticles in haemostasis and vascular medicine
Burnier, L., Fontana, P., Kwak, B. R., & Angelillo-Scherrer, A. (2009) · Thrombosis and Haemostasis · doi:10.1160/th08-08-0521 · Cited by 416
Activation-independent platelet adhesion and aggregation under elevated shear stress
Ruggeri, Z. M., Orje, J. N., Habermann, R., Federici, A. B., & Reininger, A. J. (2006) · Blood · doi:10.1182/blood-2006-04-011551 · Cited by 415
Self-citationVon Willebrand Factor in Cardiovascular Disease: Focus on Acute Coronary Syndromes
Spiel, A. O., Gilbert, J. C., & Jilma, B. (2008) · Circulation · doi:10.1161/circulationaha.107.722827 · Cited by 402
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Metadata
- Authors
- Reininger, A. J.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 2006-05-01
- Volume
- 107
- Issue
- 9
- Pages
- 3537-3545
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W1963549684
- Cited by
- 344
- References
- 0
- FWCI
- 11.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanism of platelet adhesion to von Willebrand factor and microparticle formation under high shear stress. https://app.cochat.ai/papers/10.1182/blood-2005-02-0618
- The paper
- Reininger, A. J. (2006). Mechanism of platelet adhesion to von Willebrand factor and microparticle formation under high shear stress. Blood. https://doi.org/10.1182/blood-2005-02-0618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.