Increased Detection of KIT D816V Mutation in Peripheral Blood Samples from Patients with Indolent Systemic Mastocytosis (ISM) in the Phase 2 Pioneer Study Using a High Sensitivity Droplet Digital (dd) PCR Assay Compared with Next Generation Sequencing (NGS)

George, Tracy I., Hoehn, Gerard, Lin, Hui-Min, Miller, Stephen, Akin, Cem·2020·Blood

Abstract

Introduction: Systemic mastocytosis (SM) is a rare, clonal, hematopoietic neoplasm characterized by excessive proliferation and hyperactivation of abnormal mast cells (MCs). Approximately 95% of patients with SM harbor the KIT D816V mutation within the KIT receptor tyrosine kinase, which results in constitutive activation of the KIT receptor. Abnormal activation of KIT leads to increased proliferation, survival, and hyperactivation of MCs, which can cause debilitating constitutional symptoms such as pruritus, flushing, headaches, bone pain, nausea, vomiting, diarrhea, and life-threatening anaphylaxis, across all SM subtypes.Polymerase chain reaction (PCR)-based detectionof the KIT D816V mutation in bone marrow (BM) aspirates or other extracutaneous tissues is an important tool to confirm clinical and pathological diagnosis. In addition, genomic determination of the KIT D816V variant allelic fraction (VAF) in peripheral blood (PB) or BM can serve as a potential prognostic tool and may also be used to monitor treatment efficacy over time. However, low numbers of neoplastic MCs in BM or PB samples, especially from patients with non-advanced forms of the disease (ISM and smoldering SM) can result in misdiagnosis and underestimation of disease burden. Here, we report on the performance of an adapted ddPCR assay compared with NGS for measuring the KIT D816V VAF in PB samples from patients with moderate to severe ISM and symptoms inadequately controlled with best supportive care enrolled in part 1 (randomized dose finding part to determine recommended dose) of the ongoing, randomized, double-blind, placebo-controlled phase 2 PIONEER clinical study (NCT03731260) of avapritinib, a potent and selective inhibitor of KIT D816V mutant kinases. Methods : Part 1 of PIONEER included 39 patients (3 cohorts with 10 patients at 25, 50 and 100 mg of avapritinib, and a placebo cohort of 9 patients) with a confirmed diagnosis of ISM based on World Health Organization criteria and moderate-to-severe symptoms based on Total Symptom Score as measured on the ISM-System Assessment Form (ISM-SAF). Samples of PB were collected at screening for all enrolled patients in part 1 and were evaluated by local quantitative and qualitative KIT testing, central ddPCR assay for detection of KIT D816V, and central NGS (TruSight™ Myeloid Panel) for KIT D816V and other co-mutations (central assays performed by MolecularMD, Portland, OR). Results were expressed as the percentage of patient PB samples testing positive for KIT D816V mutation (all genomic assays) and the log percent of VAF as measured by both central assay methods. Correlations of KIT D816V VAF to objective measure of MC burden, including serum tryptase levels and BM MC numbers, were performed. KIT D816V VAF was also evaluated serially in each patient over the treatment period. Results: The central ddPCR assay method detected the KIT D816V mutation in 37/39 (95%) of PB samples compared with 11/39 (28%) assayed by NGS and 30/39 (80%) of PB samples assayed locally (Table). ddPCR also demonstrated ~30-fold greater sensitivity over NGS for measuring VAF: median percent VAF (range) by ddPCR was 0.36 (0.02-30) and by NGS was 11 (1.9-31) (Figure). The lower limit of detection of VAF by ddPCR on PB samples was 95-fold lower than that of NGS (0.02% and 1.9%, respectively). In addition, ddPCR provided greater diagnostic sensitivity for ISM compared with serum tryptase >20 ng/mL (30/39, 77%) and presence of BM MC aggregates (35/39, 90%). Conclusions: The high-sensitivity ddPCR assay method detected the KIT D816V mutation in 95% of PB samples from patients with previously confirmed ISM, which provided greater sensitivity for detection of KIT D816V mutation than either NGS or local assessments, greater sensitivity over NGS for KIT D816V VAF in PB samples, and higher diagnostic sensitivity than clinical assessments of serum tryptase and BM MC aggregates. These results have implications for assay sensitivity in the diagnosis of SM and suggest that higher sensitivity testing for KIT D816V mutation using a minimally invasive PB ddPCR assay could be used as a screening tool to facilitate identification of ISM patients, including those with variable disease characteristics or low MC burden. Disclosures George: Blueprint Medicines Corporation: Consultancy, Other: I have received no funding for this research. ARUP Laboratories, owned by the University of Utah, has received funding; Allakos: Consultancy; Celgene: Consultancy; Deciphera: Other: consultancy, but has received no financial compensation for the past 12 months. Hoehn:Blueprint Medicines Corporation: Current Employment, Current equity holder in publicly-traded company. Lin:Blueprint Medicines Corporation: Current Employment, Current equity holder in publicly-traded company. Miller:Blueprint Medicines Corporation: Current Employment, Current equity holder in publicly-traded company. Akin:Novartis: Consultancy; Blueprint Medicines Corporation: Consul

Integrity signals

Registry

Crossref · 10.1182/blood-2020-136930

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In a post hoc analysis of the PIONEER trial, central ddPCR detected KIT D816V in 37/39 (95%) of PB samples compared with 11/39 (28%) by NGS and 30/39 (80%) locally, confirming a linearity between sensitivity of the technique and rate of positivity.

    “in a recent post hoc analysis of the PIONEER trial on the use of avapritinib in symptomatic ISM, the central ddPCR assay method detected the KIT D816V variant in 37/39 (95%) of PB samples compared with 11/39 (28%) analyzed by NGS and 30/39 (80%) of PB samples analyzed locally (47), a pattern that confirms a linearity between the sensitivity of the technique and the rate of positivity.”

Cited by

Sorted by citations

Authors
George, T. I., Hoehn, G., Lin, H.-M., Miller, S., & Akin, C.
Affiliations
  • University of Utah (US)
  • Blueprint Medicines (United States) (US)
  • Blueprint Medicines Corporation, Cambridge, MA
  • University of Michigan (US)
Venue
Blood
Published
2020-11-05
Volume
136
Issue
Supplement 1
Pages
7-8
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W3096628802
Cited by
10
References
0
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 3
FWCI
0.53
Type
journal article
Language
en
Open access
closed
Locations
Blood (publishedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Immunology › Mast cells and histamine
  • Health Sciences › Medicine › Gastroenterology › Gastrointestinal Tumor Research and Treatment
  • Health Sciences › Medicine › Genetics › Myeloproliferative Neoplasms: Diagnosis and Treatment
Keywords
indolent systemic mastocytosis, KIT D816V mutation, variant allele frequency, droplet digital PCR, next-generation sequencing comparison, peripheral blood, avapritinib, PIONEER trial, KIT receptor tyrosine kinase, disease burden monitoring, treatment response monitoring, sensitivity and specificity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review