Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record.

Studies on the Serum Haptoglobin Level in Hemoglobinemia and Its Influence on Renal Excretion of Hemoglobin

LAURELL, CARL-BERTIL, NYMAN, MARGARETA·1957·Blood

Abstract

A short survey is given of the literature on haptoglobin, the hemoglobin-binding serum protein, its properties and biologic variations. The principles of an electrophoretic method for quantitative determination of the serum haptoglobin are described. Electrophoretic studies showed that haptoglobin has a high affinity for hemoglobin at physiologic pH and that every haptoglobin molecule can bind at least 2 hemoglobin molecules. Observations made following the intravenous injection of hemoglobin showed: that hemoglobin administered intravenously is bound by the haptoglobin; that free hemoglobin is not demonstrable until more hemoglobin has been injected than can be bound by the haptoglobin; that the complex hemoglobin-haptoglobin is eliminated from the plasma after intravascular hemolysis or intravenous administration of hemoglobin without being excreted in the urine; that the hemoglobin-haptoglobin complex is removed from the plasma at a constant rate during the major part of the elimination period; that the haptoglobin level will fall to nil within 24 hours, if the amount of hemoglobin injected is sufficient to bind all the haptoglobin available. During the following days the rate of formation of haptoglobin can be studied. From the data available it can be concluded that hemoglobinuria cannot appear until the amount of hemoglobin administered intravenously or the amount liberated intravascularly exceeds the binding power of the haptoglobin and the reabsorption capacity of the tubules. The variation observed by earlier authors in the so-called renal threshold for hemoglobin on intravenous injection of hemoglobin can be explained among other things by the variation in the haptoglobin content in one and the same subject, i.e., if the haptoglobin level is low, the threshold value will also be low, and vice versa.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v12.6.493.493

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 273

Metadata

Authors
LAURELL, C.-B., & NYMAN, M.
Venue
Blood
Published
1957-06-01
Volume
12
Issue
6
Pages
493-506
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W2257773947
Cited by
273
References
0
FWCI
32.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Studies on the Serum Haptoglobin Level in Hemoglobinemia and Its Influence on Renal Excretion of Hemoglobin. https://app.cochat.ai/papers/10.1182/blood.v12.6.493.493
The paper
LAURELL, C.-B., & NYMAN, M. (1957). Studies on the Serum Haptoglobin Level in Hemoglobinemia and Its Influence on Renal Excretion of Hemoglobin. Blood. https://doi.org/10.1182/blood.v12.6.493.493

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.