Passive material behavior of granulocytes based on large deformation and recovery after deformation tests
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In order to better understand the in vivo rheologic behavior of white cells, we have studied the time-dependent deformability, recovery, and mechanical activation of blood granulocytes. We have used micropipette aspiration methods to measure the large deformation response and recovery after deformation characteristics of neutrophils as functions of time, temperature, and collecting media. The cell response in the pipette experiment was characterized by three time domains: the first phase was the passive deformation response to the fixed suction pressure; the second phase was an obvious transition from the passive to active motile cellular state where the cell exhibited erratic length changes in the pipette; and the third phase was the steady recovery after the suction pressure had been zeroed. Tests on white cells were carried out with three different anticoagulants to evaluate the effect of calcium on deformation and recovery behavior; also, cells were separated by centrifugation in high molecular weight dextran to determine whether or not collection and separation procedures affected the cell properties. Our results have shown that the passive deformation of granulocytes into the pipette was a continuous flow process with no approach to a static deformation limit. In addition, there was an obvious threshold pressure below which the cell would not deform and enter the micropipette. For suction pressures significantly above the threshold, granulocytes were continuously deformed with a similar functional dependence on time. The coefficient of proportionality between aspiration length and time, as well as the exponent, depended on suction pressure, pipette dimension, and temperature. It was observed that the granulocytes always recovered to the spherical state after deformation, independent of the extent of deformation or location where the cell was aspirated. Based on the recovery behavior, plus the dependence of the pressure threshold on pipette size, we propose the concept that the granulocyte membrane and cortical shell behave like a “contractile surface carpet” under tension, where the cell interior responds passively like a highly viscous liquid. The membrane cortex appears to be subject to a persistent stress (tension) of about 10(-2) dyne/cm. Our observations of passive to active transition in the pipette suction experiment indicated that granulocytes may be stimulated by deformation at room temperature. This study represents the first detailed investigation of the large deformation behavior of granulocytes, and the results indicate a simple structural model to represent the passive rheologic behavior of the granulocyte.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Passive mechanical properties of human leukocytes
Schmid-Schönbein, G. W., Sung, K. L., Tözeren, H., Skalak, R., & Chien, S. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84726-1 · Cited by 417
Morphometry of human leukocytes
Gw, S.-S., Shih, Y., & Chien, S. (1980) · Blood · doi:10.1182/blood.v56.5.866.866 · Cited by 308
Alteration of the Cell Periphery During Granulocyte Maturation: Relationship to Cell Function
Lichtman, M. A., & Weed, R. I. (1972) · Blood · doi:10.1182/blood.v39.3.301.301 · Cited by 180
The Motor of Ameboid Leukocytes
Stossel, T. P., Hartwig, J. H., Yin, H. L., & Stendahl, O. I. (1980) · Elsevier eBooks · doi:10.1016/b978-0-12-612984-7.50010-4 · Cited by 26
Cited by
Apparent viscosity and cortical tension of blood granulocytes determined by micropipet aspiration
Evans, E., & Yeung, A. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82660-8 · Cited by 788
Self-citationMechanical models for living cells—a review
Lim, C. T., Zhou, E. H., & Quek, S. T. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.008 · Cited by 719
Mechanics of Stimulated Neutrophils: Cell Stiffening Induces Retention in Capillaries
Worthen, G. S., Schwab, B., Elson, E. L., & Downey, G. P. (1989) · Science · doi:10.1126/science.2749255 · Cited by 597
New guidelines for hemorheological laboratory techniques
Baskurt, O. K., Boynard, M., Cokelet, G. C., Connes, P., Cooke, B. M., Forconi, S., Liao, F., Hardeman, M. R., Jung, F., Meiselman, H. J., et al. (2009) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-2009-1202 · Cited by 514
Deformation and flow of membrane into tethers extracted from neuronal growth cones
Hochmuth, F. M., Shao, J. Y., Dai, J., & Sheetz, M. P. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79577-2 · Cited by 378
Wu, H. W., Kuhn, T., & Moy, V. T. (1998) · Scanning · doi:10.1002/sca.1998.4950200504 · Cited by 334
Cortical shell-liquid core model for passive flow of liquid-like spherical cells into micropipets
Yeung, A., & Evans, E. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82659-1 · Cited by 289
Self-citationMechanical Properties of the Cell Nucleus and the Effect of Emerin Deficiency
Rowat, A. C., Lammerding, J., & Ipsen, J. H. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.086454 · Cited by 254
Cholesterol Depletion Increases Membrane Stiffness of Aortic Endothelial Cells
Byfield, F. J., Aranda-Espinoza, H., Romanenko, V. G., Rothblat, G. H., & Levitan, I. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.040634 · Cited by 240
Emergent complexity of the cytoskeleton: from single filaments to tissue
Huber, F., Schnauß, J., Rönicke, S., Rauch, P., Müller, K., Fütterer, C., & Käs, J. (2013) · Advances in Physics · doi:10.1080/00018732.2013.771509 · Cited by 225
Mechanics of neutrophil phagocytosis: experiments and quantitative models
Herant, M., Heinrich, V., & Dembo, M. (2006) · Journal of Cell Science · doi:10.1242/jcs.02876 · Cited by 215
Quantification of surface tension and internal pressure generated by single mitotic cells
Fischer-Friedrich, E., Hyman, A. A., Jülicher, F., Müller, D. J., & Helenius, J. (2014) · Scientific Reports · doi:10.1038/srep06213 · Cited by 211
Shao, J. Y., & Hochmuth, R. M. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79486-9 · Cited by 193
Bongrand, P. (1999) · Reports on Progress in Physics · doi:10.1088/0034-4885/62/6/202 · Cited by 186
Valberg, P. A., & Feldman, H. A. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83244-7 · Cited by 185
Advances in Micropipette Aspiration: Applications in Cell Biomechanics, Models, and Extended Studies
González-Bermúdez, B., Guinea, G. V., & Plaza, G. R. (2019) · Biophysical Journal · doi:10.1016/j.bpj.2019.01.004 · Cited by 175
A sensitive measure of surface stress in the resting neutrophil
Needham, D., & Hochmuth, R. M. (1992) · Biophysical Journal · doi:10.1016/s0006-3495(92)81970-7 · Cited by 163
Mechanics of neutrophil phagocytosis: behavior of the cortical tension
Herant, M., Heinrich, V., & Dembo, M. (2005) · Journal of Cell Science · doi:10.1242/jcs.02275 · Cited by 162
Effects of cholesterol on nano-mechanical properties of the living cell plasma membrane
Khatibzadeh, N., Gupta, S., Farrell, B., Brownell, W. E., & Anvari, B. (2012) · Soft Matter · doi:10.1039/c2sm25263e · Cited by 87
Metadata
- Authors
- Evans, E., & Kukan, B.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1984-11-01
- Volume
- 64
- Issue
- 5
- Pages
- 1028-1035
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2344607276
- Cited by
- 188
- References
- 4
- FWCI
- 1.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.