CoChat

Excess heme in sickle erythrocyte inside-out membranes: possible role in thiol oxidation

Kuross, SA, Rank, BH, Hebbel, RP · 1988 · Blood
Cited by 109

The DOI matches its Crossref record.

Abstract

It has been suggested that the development of sickle RBC membrane defects might be related to abnormal amounts of membrane-associated heme (a term we use in its generic sense to include hemoglobins, hemichromes, and free heme). Techniques previously used to measure membrane heme, however, would not distinguish between what is truly membrane-associated and what is merely trapped in RBC ghost preparations. Consequently, we have examined extensively washed inside- out membranes (IOM) prepared from normal and sickle RBC. Approximately 25% of the sickle ghost heme is lost upon conversion to IOM, but sickle IOM still have a significant excess (1.6 +/- 0.3 nmol heme/mg membrane protein compared with 0.7 +/- 0.2 nmol/mg for normal IOM, P less than .001). Amounts of ghost heme are only poorly predictive of amounts of IOM heme (r = .664). Preparation of IOM by using isotonic lysis with saponin yields virtually identical amounts of IOM heme. Small amounts of heme (less than 15%) can be displaced from IOM by using manipulations that elute spectrin, displace electrostatically bound proteins, or cleave the cytoplasmic portion of band 3. Treatment of IOM with dithiothreitol (DTT), however, displaces the most heme (35%), and this is almost reproduced (25% displacement) by the treatment of intact RBC with DTT before IOM preparation. Sequential treatment with all manipulations still leaves about 40% of the heme in sickle IOM, which indicates a compartment more intimately associated with the membrane. At least part of this is free heme without globin, as evidenced by abnormal binding of radiochloroquine to sickle IOM. Conversely, some IOM-associated globin is globin without heme because the measurement of globin per se markedly overpredicts amount of IOM heme. There is a strong correlation between RBC density and amounts of either ghost or IOM heme. Finally, the amount of membrane thiol oxidation (as measured by thiol-disulfide-exchange chromatography) does not correlate at all with ghost heme (r = .105), but it correlates well with IOM heme (r = .877, P less than .001). These data demonstrate that there are abnormal amounts of heme truly associated with sickle RBC membranes, and they are consistent with the hypothesis that this membrane-associated heme participates in the pathobiology of the sickle RBC membrane, particularly those aspects perhaps related to thiol oxidation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1182/blood.v71.4.876.876

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kuross, S., Rank, B., & Hebbel, R.
Venue
Blood
Published
1988-04-01
Volume
71
Issue
4
Pages
876-882
ISSN
  • 0006-4971 (ISSN-L)
  • 1528-0020
OpenAlex
W171117290
Cited by
109
References
0
FWCI
4.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.