The DOI matches its Crossref record.
Simultaneous measurement of reticulocyte and red blood cell indices in healthy subjects and patients with microcytic and macrocytic anemia
Abstract
Using the new Bayer H*3 hematology analyzer (Leverkusen, Germany), we have determined red blood cell and reticulocyte indices in 64 healthy subjects, in patients with microcytosis due to iron deficiency (58 patients) and heterozygous beta-thalassemia (40 patients), and in patients with macrocytosis (28 patients). We found in all cases that reticulocytes were larger than mature red cells by 24% to 35%, with a hemoglobin concentration 16% to 25% lower and a similar hemoglobin content. The correlation between red cell and reticulocyte indices was strikingly tight (r = .928 for volume, r = .929 for hemoglobin concentration, r = .972 for hemoglobin content) in all four groups, regardless of red blood cell size. The ratio of reticulocyte to red blood cell mean corpuscolar volume (MCV ratio) was constantly above 1. Inversion of the MCV ratio was observed only in four patients. It was always abrupt and transitory and was associated with erythropoietic changes leading to the production of red blood cells of a different volume (treatment of megaloblastic anemia, functional iron deficiency, bone marrow transplantation). In two cases of marrow transplantation, reticulocyte volume fell during the aplastic phase after conditioning chemotherapy and then rapidly increased up to values higher than before; this production of macroreticulocytes was the earliest sign of engraftment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
De Franceschi, L., Fattovich, G., Turrini, F., Ayi, K., Brugnara, C., Manzato, F., Noventa, F., Stanzial, A. M., Solero, P., & Corrocher, R. (2000) · Hepatology · doi:10.1053/he.2000.5789 · Cited by 446
Automated Blood Cell Counts: State of the Art
Buttarello, M., & Plebani, M. (2008) · American Journal of Clinical Pathology · doi:10.1309/ek3c7ctdknvpxvtn · Cited by 355
Erythropoietin, iron, and erythropoiesis
Goodnough, L. T., Skikne, B., & Brugnara, C. (2000) · Blood · doi:10.1182/blood.v96.3.823 · Cited by 300
Quality counts: new parameters in blood cell counting
BRIGGS, C. (2009) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2009.01160.x · Cited by 260
Iron deficiency in sports-definition, influence on performance and therapy
Clénin, G., Cordes, M., Huber, A., Schumacher, Y. O., Noack, P., Scales, J., & Kriemler, S. (2015) · Swiss Medical Weekly · doi:10.4414/smw.2015.14196 · Cited by 170
Metadata
- Authors
- d'Onofrio, G., Chirillo, R., Zini, G., Caenaro, G., Tommasi, M., & Micciulli, G.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 1995-02-01
- Volume
- 85
- Issue
- 3
- Pages
- 818-823
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2267189664
- Cited by
- 172
- References
- 0
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous measurement of reticulocyte and red blood cell indices in healthy subjects and patients with microcytic and macrocytic anemia. https://app.cochat.ai/papers/10.1182/blood.v85.3.818.bloodjournal853818
- The paper
- d'Onofrio, G., Chirillo, R., Zini, G., Caenaro, G., Tommasi, M., & Micciulli, G. (1995). Simultaneous measurement of reticulocyte and red blood cell indices in healthy subjects and patients with microcytic and macrocytic anemia. Blood. https://doi.org/10.1182/blood.v85.3.818.bloodjournal853818
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.