ICL670A: a new synthetic oral chelator: evaluation in hypertransfused rats with selective radioiron probes of hepatocellular and reticuloendothelial iron stores and in iron-loaded rat heart cells in culture
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
ICL670A (formerly CGP 72 670) or 4-[3,5-bis-(hydroxyphenyl)-1,2,4-triazol-1-yl]- benzoic acid is a tridentate iron-selective synthetic chelator of the bis-hydroxyphenyl-triazole class of compounds. The present studies used selective radioiron probes of hepatocellular and reticuloendothelial (RE) iron stores in hypertransfused rats and iron-loaded heart cells to define the source of iron chelated in vivo by ICL670A and its mode of excretion, to examine its ability to remove iron directly from iron-loaded myocardial cells, and to examine its ability to interact with other chelators through a possible additive or synergistic effect. Results indicate that ICL670A given orally is 4 to 5 times more effective than parenteral deferoxamine (DFO) in promoting the excretion of chelatable iron from hepatocellular iron stores. The pattern of iron excretion produced by ICL670A is quite different from that of DFO and all iron excretion is restricted to the bile regardless of whether it is derived from RE or hepatocellular iron stores. Studies in heart cell cultures have shown a favorable interaction between DFO and ICL670A manifested in improved chelating efficiency of ICL670A, which is most probably explained by an exchange of chelated iron between ICL670A and DFO. These unique chelating properties of ICL670A may have practical implications for current efforts to design better therapeutic strategies for the management of transfusional iron overload.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Richardson, D. R., & Ponka, P. (1998) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(98)90180-9 · Cited by 126
Cited by
The Evolution of Iron Chelators for the Treatment of Iron Overload Disease and Cancer
Kalinowski, D. S., & Richardson, D. R. (2005) · Pharmacological Reviews · doi:10.1124/pr.57.4.2 · Cited by 721
Cappellini, M. D. (2006) · Blood · doi:10.1182/blood-2005-08-3430 · Cited by 717
Rachmilewitz, E. A., & Giardina, P. J. (2011) · Blood · doi:10.1182/blood-2010-08-300335 · Cited by 417
Neufeld, E. J. (2006) · Blood · doi:10.1182/blood-2006-02-002394 · Cited by 315
Design of iron chelators with therapeutic application
Liu, Z. D., & Hider, R. C. (2002) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(02)00050-4 · Cited by 287
Metadata
- Authors
- Hershko, C., Konijn, A. M., Nick, H. P., Breuer, W., Cabantchik, Z. I., & Link, G.
- Venue
- Blood
- Publisher
- American Society of Hematology
- Published
- 2001-02-15
- Volume
- 97
- Issue
- 4
- Pages
- 1115-1122
- ISSN
- 0006-4971 (ISSN-L)
- 1528-0020
- OpenAlex
- W2009553907
- Cited by
- 151
- References
- 1
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ICL670A: a new synthetic oral chelator: evaluation in hypertransfused rats with selective radioiron probes of hepatocellular and reticuloendothelial iron stores and in iron-loaded rat heart cells in culture. https://app.cochat.ai/papers/10.1182/blood.v97.4.1115
- The paper
- Hershko, C., Konijn, A. M., Nick, H. P., Breuer, W., Cabantchik, Z. I., & Link, G. (2001). ICL670A: a new synthetic oral chelator: evaluation in hypertransfused rats with selective radioiron probes of hepatocellular and reticuloendothelial iron stores and in iron-loaded rat heart cells in culture. Blood. https://doi.org/10.1182/blood.v97.4.1115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.