Detecting active pulmonary tuberculosis with a breath test using nanomaterial-based sensors
Open accessThe DOI matches its Crossref record.
Abstract
To the Editor: Detecting active tuberculosis (TB) remains a major global public health challenge [1]. The tuberculin skin test does not distinguish latent from active TB [2]. The interferon-γ release assays have similar limitations [3]. Acid-fast bacilli staining of sputum has a high false-negative rate (up to 50%) [4]. Nucleic acid amplification tests (NAATs), such as GeneXpert MTB/RIF (Cepheid, Sunnyvale, CA, USA), are accurate but require a good infrastructure and the necessity to obtain a good quality sputum sample, which is often unobtainable in more than a third of HIV-infected persons [5, 6]. Given these unmet needs, we explored the use of a novel, rapid, simple and inexpensive point-of-care test for the diagnosis of TB [7]. The approach is based on the detection of volatile organic compounds (VOCs) that are emitted from infected cells and released in exhaled breath [8, 9]. Using gas chromatography linked with mass spectrometry, researchers have previously reported identification of TB-related VOCs in the exhaled breath, though there has been low accuracy in detection (80–85%) [10]. In this study, we explore the possibility of active TB detection via the analysis of exhaled breath using a novel technology of organically modified nanomaterial-based sensors. Such cross-reactive sensors are highly sensitive to the collective changes in the VOCs spectrum [8]. Therefore, we designed a case–control study, in which breath and sputum sampling was performed in 210 adult participants, after informed consent, at three sites in Cape Town, South Africa, between November 2011 and March 2012. The study population consisted of two main subgroups. The first subgroup included those in …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationNakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citationBroza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Self-citationMultiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c05657 · Cited by 384
Self-citationAdvanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Self-citation
Metadata
- Authors
- Nakhleh, M. K., Jeries, R., Gharra, A., Binder, A., Broza, Y. Y., Pascoe, M., Dheda, K., & Haick, H.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2014-04-30
- Volume
- 43
- Issue
- 5
- Pages
- 1522-1525
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2035157252
- Cited by
- 103
- References
- 0
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detecting active pulmonary tuberculosis with a breath test using nanomaterial-based sensors. https://app.cochat.ai/papers/10.1183/09031936.00019114
- The paper
- Nakhleh, M. K., Jeries, R., Gharra, A., Binder, A., Broza, Y. Y., Pascoe, M., Dheda, K., & Haick, H. (2014). Detecting active pulmonary tuberculosis with a breath test using nanomaterial-based sensors. European Respiratory Journal. https://doi.org/10.1183/09031936.00019114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.