Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
This article reports on a noninvasive approach in detecting and following-up individuals who are at-risk or have an existing COVID-19 infection, with a potential ability to serve as an epidemic control tool. The proposed method uses a developed breath device composed of a nanomaterial-based hybrid sensor array with multiplexed detection capabilities that can detect disease-specific biomarkers from exhaled breath, thus enabling rapid and accurate diagnosis. An exploratory clinical study with this approach was examined in Wuhan, China, during March 2020. The study cohort included 49 confirmed COVID-19 patients, 58 healthy controls, and 33 non-COVID lung infection controls. When applicable, positive COVID-19 patients were sampled twice: during the active disease and after recovery. Discriminant analysis of the obtained signals from the nanomaterial-based sensors achieved very good test discriminations between the different groups. The training and test set data exhibited respectively 94% and 76% accuracy in differentiating patients from controls as well as 90% and 95% accuracy in differentiating between patients with COVID-19 and patients with other lung infections. While further validation studies are needed, the results may serve as a base for technology that would lead to a reduction in the number of unneeded confirmatory tests and lower the burden on hospitals, while allowing individuals a screening solution that can be performed in PoC facilities. The proposed method can be considered as a platform that could be applied for any other disease infection with proper modifications to the artificial intelligence and would therefore be available to serve as a diagnostic tool in case of a new disease outbreak.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For both of these examples, interface problems mainly arise in heterogeneous integration of different materials, such as for material bonding and embedding, which can be addressed by micromechanics, chemical bonding links, etc.[609]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [609]
Citations
Cites
Clinical characteristics of coronavirus disease 2019 in China
Guan, W.-J., Ni, Z.-Y., Hu, Y., Liang, W.-H., Ou, C.-Q., He, J.-X., Liu, L., Shan, H., Lei, C.-L., Hui, D. S. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2002032 · Cited by 30,246
Self-citationChen, N., Zhou, M., Dong, X., Qu, J., Gong, F., Han, Y., Qiu, Y., Wang, J., Liu, Y., Wei, Y., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30211-7 · Cited by 21,415
Self-citationSensitivity of Chest CT for COVID-19: Comparison to RT-PCR
Fang, Y., Zhang, H., Xie, J., Lin, M., Ying, L., Pang, P., & Ji, W. (2020) · Radiology · doi:10.1148/radiol.2020200432 · Cited by 3,354
Wynants, L., Van Calster, B., Bonten, M. M., Collins, G. S., Debray, T. P., De Vos, M., Haller, M. C., Heinze, G., Moons, K. G., Riley, R. D., et al. (2020) · doi:10.1101/2020.03.24.20041020 · Cited by 3,070
Covid-19 in Critically Ill Patients in the Seattle Region — Case Series
Bhatraju, P. K., Ghassemieh, B. J., Nichols, M., Kim, R., Jerome, K. R., Nalla, A. K., Greninger, A. L., Pipavath, S., Wurfel, M. M., Evans, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004500 · Cited by 2,583
Seo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Self-citationInterpreting a covid-19 test result
Watson, J., Whiting, P. F., & Brush, J. E. (2020) · BMJ · doi:10.1136/bmj.m1808 · Cited by 712
Nakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citation
Research works printed but not linked: 2
- Watson J., 2020, BMJ., 369
- 10.1136/bmj.m1328 · doi:10.1136/bmj.m1328 · Paper page
Cited by
Diagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationThe emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
“…cancer [204], lung cancer [205], brain lesion [206], coronary artery disease [207], diabetes [208], esophageal adenocarcinoma [209], COVID-19 [210], heart failure [211], skin cancers [212], AI-based techniques are facilitating real-time monitoring capabilities and personalized health…”
BackgroundApplied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
“CRP might be a non-specific clinical inflammation marker, but it can be used to set therapeutic indications, monitor treatment success and disease progression in communicable (such as coronavirus disease 2019 (COVID-19)) and non-communicable (such as rheumatoid arthritis) diseases.”
Self-citation
Metadata
- Authors
- Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., Liu, W., Zhou, S., Jin, W., Zhang, Q., Hu, D., Lin, L., Zhang, Q., Li, W., Wang, J., Liu, H., Pan, Y., & Haick, H.
- Affiliations
- University of Science and Technology of China (CN)
- Technion – Israel Institute of Technology (IL)
- First Affiliated Hospital of Anhui Medical University (CN)
- Department of Respiratory Disease, Anhui Provincial Chest Hospital, 230000, Hefei, Anhui Province, People’s Republic of China
- Corresponding author
- Liu, Hu
- Pan, Yueyin
- Haick, Hossam
- ORCID
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-18
- Volume
- 14
- Issue
- 9
- Pages
- 12125-12132
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3049021859
- Cited by
- 384
- References
- 26
- Citations by year
- 2026: 10 · 2025: 33 · 2024: 51 · 2023: 54 · 2022: 90 · 2021: 115 · 2020: 30
- FWCI
- 22.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Technion-Israel Institute of Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- COVID-19 detection, breath analysis, multiplexed sensing, non-invasive diagnosis, disease-specific biomarkers, point-of-care screening, epidemic control, SARS-CoV-2
- MeSH terms
- Data Accuracy, Betacoronavirus, COVID-19, SARS-CoV-2, Breath Tests, China, Female, Humans, Male, Middle Aged, Pneumonia, Viral, Respiratory System, Sensitivity and Specificity, Biomarkers, Coronavirus Infections, Asian People, Nanostructures, Pandemics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath. https://app.cochat.ai/papers/10.1021/acsnano.0c05657
- The paper
- Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., Liu, W., Zhou, S., Jin, W., Zhang, Q., Hu, D., Lin, L., Zhang, Q., Li, W., Wang, J., . . . Haick, H. (2020). Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath. ACS Nano. https://doi.org/10.1021/acsnano.0c05657
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.