CoChat

CFTR biomarkers: time for promotion to surrogate end-point

Open access
De Boeck, K., Kent, L., Davies, J., Derichs, N., Amaral, M., Rowe, S.M., Middleton, P., de Jonge, H., Bronsveld, I., Wilschanski, M., Melotti, P., Danner-Boucher, I., Boerner, S., Fajac, I., Southern, K., de Nooijer, R.A., Bot, A., de Rijke, Y., de Wachter, E., Leal, T., Vermeulen, F., Hug, M.J., Rault, G., Nguyen-Khoa, T., Barreto, C., Proesmans, M., Sermet-Gaudelus, I. · 2013 · European Respiratory Journal
Cited by 111

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

In patients with cystic fibrosis, cystic fibrosis transmembrane conductance regulator (CFTR) biomarkers, such as sweat chloride concentration and/or nasal potential difference, are used as end-points of efficacy in phase-III clinical trials with the disease modifying drugs ivacaftor (VX-770), VX809 and ataluren. The aim of this project was to review the literature on reliability, validity and responsiveness of nasal potential difference, sweat chloride and intestinal current measurement in patients with cystic fibrosis. Data on clinimetric properties were collected for each biomarker and reviewed by an international team of experts. Data on reliability, validity and responsiveness were tabulated. In addition, narrative answers to four key questions were discussed and agreed by the team of experts. The data collected demonstrated the reliability, validity and responsiveness of nasal potential difference. Fewer data were found on reliability of sweat chloride concentration; however, validity and responsiveness were demonstrated. Validity was demonstrated for intestinal current measurement, but further information is required on reliability and responsiveness. For all three end-points, normal values were collected and further research requirements were proposed. This body of work adds useful information to support the promotion of CFTR biomarkers to surrogate end-points and to guide further research in the area.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00057512

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 111

Metadata

Authors
De Boeck, K., Kent, L., Davies, J., Derichs, N., Amaral, M., Rowe, S. M., Middleton, P., de Jonge, H., Bronsveld, I., Wilschanski, M., Melotti, P., Danner-Boucher, I., Boerner, S., Fajac, I., Southern, K., de Nooijer, R. A., Bot, A., de Rijke, Y., de Wachter, E., Leal, T., Vermeulen, F., Hug, M. J., Rault, G., Nguyen-Khoa, T., Barreto, C., Proesmans, M., & Sermet-Gaudelus, I.
Venue
European Respiratory Journal
Published
2012-08-09
Volume
41
Issue
1
Pages
203-216
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2126209714
Cited by
111
References
1
FWCI
9.01
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CFTR biomarkers: time for promotion to surrogate end-point. https://app.cochat.ai/papers/10.1183/09031936.00057512
The paper
De Boeck, K., Kent, L., Davies, J., Derichs, N., Amaral, M., Rowe, S. M., Middleton, P., de Jonge, H., Bronsveld, I., Wilschanski, M., Melotti, P., Danner-Boucher, I., Boerner, S., Fajac, I., Southern, K., de Nooijer, R. A., Bot, A., de Rijke, Y., de Wachter, E., . . . Sermet-Gaudelus, I. (2013). CFTR biomarkers: time for promotion to surrogate end-point. European Respiratory Journal. https://doi.org/10.1183/09031936.00057512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.