Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 693

The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.

ERS guidelines on the assessment of cough

Open access
Morice, A. H., Fontana, G. A., Belvisi, M. G., Birring, S. S., Chung, K. F., Dicpinigaitis, P. V., Kastelik, J. A., McGarvey, L. P., Smith, J. A., Tatar, M., Widdicombe, J.·2007·European Respiratory Journal

Abstract

### Cough 1) All basic scientific articles should refer to cough as a three-phase motor act. For the purposes of acoustic recordings in clinical studies, however, cough should be described as a forced expulsive manoeuvre or manoeuvres against a closed glottis that are associated with a characteristic sound or sounds. 2) All scientific articles should include a clear definition of what the authors have used as their definition of cough. ### Capsaicin and citric acid inhalation cough challenge 1) The methodology for the performance of inhalation cough challenge should be standardised so as to facilitate universal interpretation and comparison of data generated by different laboratories. 2) Comprehensive normal ranges need to be developed using the standardised methodology advocated in the present document. 3) The single-breath concentration–response method using a flow-limited dosimeter is recommended for most experimental protocols. 4) Both C2 and C5 should be recorded. 5) Since there is wide inter-individual variation, cough challenge data have no intrinsic significance, but may usefully be used to follow change in cough reflex sensitivity in an individual. ### Cough induced by inhalation of aqueous solutions 1) Aerosolised aqueous solutions represent a useful experimental tool in cough research. 2) The cough challenge with ultrasonic distilled water (fog) is difficult to standardise since it is highly dependent upon nebuliser output. 3) Consideration should be given to potential adverse events, such as bronchoconstriction and cross-infection. ### Cough monitors 1) No cough monitor is currently the gold standard. 2) Monitors should be developed that are ambulatory, are capable of being digitally processed and permit prolonged (24-h) recording. 3) There is little to commend any particular method of quantifying cough over any other. ### Assessment of quality of life of patients with chronic cough 1) Cough can have profound effects on health status, which can be assessed by cough-specific health status questionnaires. 2) Cough visual analogue scale (VAS, 0–100 mm) should be used to assess cough severity in patients with chronic cough. 3) Patients with chronic cough should be assessed with cough-specific quality-of-life questionnaires in clinical studies. ### Animal models of cough 1) The most useful animal model of cough is …

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00101006

Cites

94 of 94 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 94 references

Cited by

See all 693

Metadata

Authors
Morice, A. H., Fontana, G. A., Belvisi, M. G., Birring, S. S., Chung, K. F., Dicpinigaitis, P. V., Kastelik, J. A., McGarvey, L. P., Smith, J. A., Tatar, M., & Widdicombe, J.
Venue
European Respiratory Journal
Published
2007-05-31
Volume
29
Issue
6
Pages
1256-1276
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2128836390
Cited by
693
References
94
FWCI
20.83
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ERS guidelines on the assessment of cough. https://app.cochat.ai/papers/10.1183/09031936.00101006
The paper
Morice, A. H., Fontana, G. A., Belvisi, M. G., Birring, S. S., Chung, K. F., Dicpinigaitis, P. V., Kastelik, J. A., McGarvey, L. P., Smith, J. A., Tatar, M., & Widdicombe, J. (2007). ERS guidelines on the assessment of cough. European Respiratory Journal. https://doi.org/10.1183/09031936.00101006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.