Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Respiratory impedance in healthy subjects: baseline values and bronchodilator response

Open access
Oostveen, Ellie, Boda, Krisztina, van der Grinten, Chris P.M., James, Alan L., Young, Sally, Nieland, Hans, Hantos, Zoltán·2013·European Respiratory Journal

Abstract

Because of the minimal demand for cooperation by the subject, the forced oscillation technique is increasingly employed in routine lung function testing. However, comprehensive and device-independent values of respiratory impedance at baseline and after bronchodilation have not been established for healthy adults. The aim of this multicentre study was to collect impedance data from 4 to 26 Hz in healthy Caucasian subjects between 18 and 80 years of age. Five different devices were employed to assess baseline values and the bronchodilator response. Altogether, 368 subjects were examined. Despite adjustment for anthropometry, the impedance spectra differed in frequency dependence between the centres, and hence could not be pooled. However, resistance at all frequencies except 20 and 25 Hz, and the low-frequency (≤14 Hz) values of reactance did not exhibit a centre dependence. The regression equations for resistance reflected a greater height dependence in males and a greater weight dependence in both males and females than those published previously. Bronchodilation resulted in a statistically significant decrease (11%) in resistance and a 95th percentile equal to a 32% decrease in resistance at low frequency. We conclude that rigorous calibration procedures should be developed to ensure data compatibility. Furthermore, new reference equations based on different setups are recommended to replace those established with a single device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00126212

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 262

Metadata

Authors
Oostveen, E., Boda, K., van der Grinten, C. P. M., James, A. L., Young, S., Nieland, H., & Hantos, Z.
Venue
European Respiratory Journal
Published
2013-04-18
Volume
42
Issue
6
Pages
1513-1523
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2080475703
Cited by
262
References
18
FWCI
6.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Respiratory impedance in healthy subjects: baseline values and bronchodilator response. https://app.cochat.ai/papers/10.1183/09031936.00126212
The paper
Oostveen, E., Boda, K., van der Grinten, C. P. M., James, A. L., Young, S., Nieland, H., & Hantos, Z. (2013). Respiratory impedance in healthy subjects: baseline values and bronchodilator response. European Respiratory Journal. https://doi.org/10.1183/09031936.00126212

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.