Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 357

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Exploring the role of CT densitometry: a randomised study of augmentation therapy in α1-antitrypsin deficiency

Open access
Dirksen, A., Piitulainen, E., Parr, D. G., Deng, C., Wencker, M., Shaker, S. B., Stockley, R. A.·2009·European Respiratory Journal

Abstract

Assessment of emphysema-modifying therapy is difficult, but newer outcome measures offer advantages over traditional methods. The EXAcerbations and Computed Tomography scan as Lung End-points (EXACTLE) trial explored the use of computed tomography (CT) densitometry and exacerbations for the assessment of the therapeutic effect of augmentation therapy in subjects with α 1-antitrypsin (α 1-AT) deficiency. In total, 77 subjects (protease inhibitor type Z) were randomised to weekly infusions of 60 mg·kg−1 human α 1-AT (Prolastin®) or placebo for 2–2.5 yrs. The primary end-point was change in CT lung density, and an exploratory approach was adopted to identify optimal methodology, including two methods of adjustment for lung volume variability and two statistical approaches. Other end-points were exacerbations, health status and physiological indices. CT was more sensitive than other measures of emphysema progression, and the changes in CT and forced expiratory volume in 1 s were correlated. All methods of densitometric analysis concordantly showed a trend suggestive of treatment benefit (p-values for Prolastin®versus placebo ranged 0.049–0.084). Exacerbation frequency was unaltered by treatment, but a reduction in exacerbation severity was observed. In patients with α 1-AT deficiency, CT is a more sensitive outcome measure of emphysema-modifying therapy than physiology and health status, and demonstrates a trend of treatment benefit from α 1-AT augmentation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.00159408

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 357

Metadata

Authors
Dirksen, A., Piitulainen, E., Parr, D. G., Deng, C., Wencker, M., Shaker, S. B., & Stockley, R. A.
Venue
European Respiratory Journal
Published
2009-02-05
Volume
33
Issue
6
Pages
1345-1353
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2081169091
Cited by
357
References
21
FWCI
18.55
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Exploring the role of CT densitometry: a randomised study of augmentation therapy in α1-antitrypsin deficiency. https://app.cochat.ai/papers/10.1183/09031936.00159408
The paper
Dirksen, A., Piitulainen, E., Parr, D. G., Deng, C., Wencker, M., Shaker, S. B., & Stockley, R. A. (2009). Exploring the role of CT densitometry: a randomised study of augmentation therapy in α1-antitrypsin deficiency. European Respiratory Journal. https://doi.org/10.1183/09031936.00159408

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.