Age- and height-based prediction bias in spirometry reference equations
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Prediction bias in spirometry reference equations can arise from combining equations for different age groups, rounding age or height to integers or using self-reported height. To assess the bias arising from these sources, the fit of 13 prediction equations was tested against the Global Lungs Initiative (GLI) dataset using spirometric data from 55,136 healthy Caucasians (54% female). The effects on predicted values of using whole-year age versus decimal age, and of a 1% bias in height, were quantified. In children, the prediction bias relative to GLI ranged from -22% to +17%. Switching equations at 18 yrs of age led to biases of between -846 (-14%) and +1,309 (+38%) mL. Using age in whole years rather than decimal age introduced biases from -8% to +7%, whereas a 1% overestimation of height introduced bias that ranged from +1% to +40%. Bias was greatest in children and adolescents, and in short elderly subjects. Using a single spirometry equation applicable across all ages and populations reduces prediction bias. Measuring and recording age and height accurately are also essential if bias is to be minimised.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, M. R., Hankinson, J., Brusasco, V., Burgos, F., Casaburi, R., Coates, A., Crapo, R., Enright, P., van der Grinten, C. P. M., Gustafsson, P., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00034805 · Cited by 15,627
Quanjer, P. H., Stanojevic, S., Cole, T. J., Baur, X., Hall, G. L., Culver, B. H., Enright, P. L., Hankinson, J. L., Ip, M. S. M., Zheng, J., et al. (2012) · European Respiratory Journal · doi:10.1183/09031936.00080312 · Cited by 5,919
Self-citationLung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Self-citationSpirometric Reference Values from a Sample of the General U.S. Population
HANKINSON, J. L., ODENCRANTZ, J. R., & FEDAN, K. B. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.9712108 · Cited by 4,206 · cited 5×
“0 years of age according to the various child and adult prediction equations [2-5,7,9-17].”
BackgroundMethodInfluential(1993) · PubMed · Cited by 3,827
Standardization of Spirometry — 1987 Update
Buist, A. S. (1987) · American Review of Respiratory Disease · doi:10.1164/ajrccm/136.5.1073 · Cited by 3,266
Changes in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907 · cited 3×
“0 years of age according to the various child and adult prediction equations [2-5,7,9-17].”
BackgroundMethodReference spirometric values using techniques and equipment that meet ATS recommendations.
Terrin, M. (1981) · PubMed · doi:10.1164/arrd.1981.124.6.763c · Cited by 1,374
Pulmonary Function Testing in Children. Techniques and Standards
(1973) · Clinical Pediatrics · doi:10.1177/000992287301200517 · Cited by 761
Reference Ranges for Spirometry Across All Ages: A New Approach
Stanojevic, S., Wade, A., Stocks, J., Hankinson, J., Coates, A. L., Pan, H., Rosenthal, M., Corey, M., Lebecque, P., & Cole, T. J. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200708-1248oc · Cited by 699 · cited 3×
“In addition, it allows the lower limit of normal (usually the 5 percentile), which varies appreciably with age [10,15-16,22], to be modelled properly.”
BackgroundMethodSelf-citation
Cited by
Quanjer, P. H., Stanojevic, S., Cole, T. J., Baur, X., Hall, G. L., Culver, B. H., Enright, P. L., Hankinson, J. L., Ip, M. S. M., Zheng, J., et al. (2012) · European Respiratory Journal · doi:10.1183/09031936.00080312 · Cited by 5,919
Self-citationGraham, B. L., Steenbruggen, I., Miller, M. R., Barjaktarevic, I. Z., Cooper, B. G., Hall, G. L., Hallstrand, T. S., Kaminsky, D. A., McCarthy, K., McCormack, M. C., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201908-1590st · Cited by 4,305
Self-citationCulver, B. H., Graham, B. L., Coates, A. L., Wanger, J., Berry, C. E., Clarke, P. K., Hallstrand, T. S., Hankinson, J. L., Kaminsky, D. A., MacIntyre, N. R., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201710-1981st · Cited by 649
Self-citationRisk factors and early origins of chronic obstructive pulmonary disease
Postma, D. S., Bush, A., & van den Berge, M. (2015) · The Lancet · doi:10.1016/s0140-6736(14)60446-3 · Cited by 541
Campos-Rodriguez, F., Martinez-Garcia, M. A., Martinez, M., Duran-Cantolla, J., Peña, M. D. L., Masdeu, M. J., Gonzalez, M., Campo, F. D., Gallego, I., Marin, J. M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1671oc · Cited by 386
Sex differences in respiratory function
LoMauro, A., & Aliverti, A. (2018) · Breathe · doi:10.1183/20734735.000318 · Cited by 353
Cooper, B. G., Stocks, J., Hall, G. L., Culver, B., Steenbruggen, I., Carter, K. W., Thompson, B. R., Graham, B. L., Miller, M. R., Ruppel, G., et al. (2017) · Breathe · doi:10.1183/20734735.012717 · Cited by 256
Self-citationLung function after preterm birth: development from mid-childhood to adulthood
Vollsæter, M., Røksund, O. D., Eide, G. E., Markestad, T., & Halvorsen, T. (2013) · Thorax · doi:10.1136/thoraxjnl-2012-202980 · Cited by 212
Blood eosinophil count in the general population: typical values and potential confounders
Hartl, S., Breyer, M.-K., Burghuber, O. C., Ofenheimer, A., Schrott, A., Urban, M. H., Agusti, A., Studnicka, M., Wouters, E. F. M., & Breyer-Kohansal, R. (2020) · European Respiratory Journal · doi:10.1183/13993003.01874-2019 · Cited by 186
Reference Values for Maximal Inspiratory Pressure: A Systematic Review
Pessoa, I. M. S., Parreira, V. F., Fregonezi, G. A., Sheel, A. W., Chung, F., & Reid, W. D. (2014) · Canadian Respiratory Journal · doi:10.1155/2014/982374 · Cited by 174
Contributors to Serum NfL Levels in People without Neurologic Disease
Fitzgerald, K. C., Sotirchos, E. S., Smith, M. D., Lord, H., DuVal, A., Mowry, E. M., & Calabresi, P. A. (2022) · Annals of Neurology · doi:10.1002/ana.26446 · Cited by 101
Metadata
- Authors
- Quanjer, P. H., Hall, G. L., Stanojevic, S., Cole, T. J., & Stocks, J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2011-12-19
- Volume
- 40
- Issue
- 1
- Pages
- 190-197
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2126699286
- Cited by
- 211
- References
- 34
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.