Breathing pattern and gas exchange at peak exercise in COPD patients with and without tidal flow limitation at rest
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Expiratory flow limitation (FL) at rest is frequently present in chronic obstructive pulmonary disease (COPD) patients. It promotes dynamic hyperinflation with a consequent decrease in inspiratory capacity (IC). Since in COPD resting IC is strongly correlated with exercise tolerance, this study hypothesized that this is due to limitation of the maximal tidal volume (VT,max) during exercise by the reduced IC. The present study investigated the role of tidal FL at rest on: 1) the relationship of resting IC to VT,max; and 2) on gas exchange during peak exercise in COPD patients. Fifty-two stable COPD patients were studied at rest, using the negative expiratory pressure technique to assess the presence of FL, and during incremental symptom-limited cycling exercise to evaluate exercise performance. At rest, FL was present in 29 patients. In the 52 patients, a close relationship of VT,max to IC was found using non-normalized values (r=0.77; p<0.0001), and stepwise regression analysis selected IC as the only significant predictor of VT,max. Subgroup analysis showed that this was also the case for patients both with and without FL (r=0.70 and 0.76, respectively). In addition, in FL patients there was an increase (p<0.002) in arterial carbon dioxide partial pressure at peak exercise, mainly due to a relatively low VT,max and consequent increase in the physiological dead space (VD)/VT ratio. The arterial oxygen partial pressure also decreased at peak exercise in the FL patients (p<0.05). In conclusion, in chronic obstructive pulmonary disease patients the maximal tidal volume, and hence maximal oxygen consumption, are closely related to the reduced inspiratory capacity. The flow limited patients also exhibit a significant increase in arterial carbon dioxide partial pressure and a decrease in arterial oxygen partial pressure during peak exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Changes in the normal maximal expiratory flow-volume curve with growth and aging.
Knudson, R. J., Lebowitz, M. D., Holberg, C. J., & Burrows, B. A. (1983) · PubMed · doi:10.1164/arrd.1983.127.6.725 · Cited by 1,907
Maximal respiratory pressures: normal values and relationship to age and sex.
Black, L. F., & Hyatt, R. E. (1969) · PubMed · doi:10.1164/arrd.1969.99.5.696 · Cited by 1,877
O'Donnell, D. E., & Webb, K. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.5.1351 · Cited by 543 · cited 4×
“Tidal FL promotes dynamic hyperinflation (DH) with concurrent decrease of the inspiratory capacity (IC) [2, 4, 5].”
BackgroundResultInfluentialDiaz, O., Villafranca, C., Ghezzo, H., Borzone, G., Leiva, A., Milic-Emil, J., & Lisboa, C. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16b14.x · Cited by 300 · cited 5×
“Tidal FL promotes dynamic hyperinflation (DH) with concurrent decrease of the inspiratory capacity (IC) [2, 4, 5].”
BackgroundResultSelf-citation
Cited by
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Use of exercise testing in the evaluation of interventional efficacy: an official ERS statement
Puente-Maestu, L., Palange, P., Casaburi, R., Laveneziana, P., Maltais, F., Neder, J. A., O'Donnell, D. E., Onorati, P., Porszasz, J., Rabinovich, R., et al. (2016) · European Respiratory Journal · doi:10.1183/13993003.00745-2015 · Cited by 412
O'Donnell, D. E., Voduc, N., Fitzpatrick, M., & Webb, K. A. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00072703 · Cited by 365
Flow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
Regional chest wall volumes during exercise in chronic obstructive pulmonary disease
Aliverti, A. (2004) · Thorax · doi:10.1136/thorax.2003.011494 · Cited by 226
“exhibiting quantitatively similar changes in end expiratory Vcw using optoelectronic measurement to those in EELV measured using the IC technique and with similar impairments in resting spirometry and expiratory flow. Data from the composite tidal flow-volume loops in our patients are compatible with the presence of r…”
Metadata
- Authors
- Díaz, O., Villafranca, C., Ghezzo, H., Borzone, G., Leiva, A., Milic-Emili, J., & Lisboa, C.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2001-06
- Volume
- 17
- Issue
- 6
- Pages
- 1120-1127
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2152906506
- Cited by
- 69
- References
- 4
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.