Ventricular mass index using magnetic resonance imaging accurately estimates pulmonary artery pressure
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Magnetic resonance imaging (MRI) can provide accurate anatomical measurements of the cardiac ventricles. This study investigated whether a calculated ventricular mass index (VMI) would provide an accurate means of estimating pulmonary artery pressure noninvasively, and compared the results with conventional Doppler echocardiography and invasive measurement. A total of 26 subjects referred for investigation of pulmonary hypertension were studied by MRI and echocardiography within 2 weeks of cardiac catheterisation. The correlations for mean pulmonary artery pressure were as follows: VMI (ratio of right ventricular mass over left ventricular mass) r=0.81; pulmonary artery systolic pressure (echocardiography) r=0.77. The confidence intervals for the VMI were narrower than for echocardiography. Sensitivity and specificity for pulmonary hypertension were 84 and 71% respectively for the VMI compared with 89 and 57% for echocardiography. The calculated ventricular mass index provides an accurate and practical means of estimating pulmonary artery pressure noninvasively in pulmonary hypertension and may provide a more accurate estimate than Doppler echocardiography. This may be because it reflects the right ventricular response to sustained pulmonary hypertension over a long period and is not influenced by short-term physiological variables affecting echocardiography, such as heart rate, posture, hydration status and oxygen supplementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
D'Alonzo, G. E., Barst, R. J., Ayres, S. M., Bergofsky, E. H., Brundage, B. H., Detre, K. M., Fishman, A. P., Goldring, R. M., Groves, B. M., Kernis, J. T., et al. (1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-115-5-343 · Cited by 3,501 · cited 1×
“Prognosis is related to mean pulmonary artery pressure (MPAP) measured at right heart catheterisation (RHC) [1], and repeated measurements are often necessary to assess disease progression and the response to treatment.”
BackgroundYock, P. G., & Popp, R. L. (1984) · Circulation · doi:10.1161/01.cir.70.4.657 · Cited by 1,640 · cited 2×
“The most widely used noninvasive technique, Doppler echocardiography (ECHO) [2] is safe and widely available, but has several limitations.”
MethodLorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717 · cited 1×
“[5] however only three of the seven subjects without pulmonary hypertension at rest fell within the suggested normal range for right RVM.”
BackgroundKatz, J., Whang, J., Boxt, L. M., & Barst, R. J. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90327-w · Cited by 181 · cited 12×
“Subjects were also divided into those with normal MPAP at RHC (normals) and those with raised MPAP (PAHT).”
BackgroundMethodInfluentialKondo, C., Caputo, G. R., Masui, T., Foster, E., O'Sullivan, M., Stulbarg, M. S., Golden, J., Catterjee, K., & Higgins, C. B. (1992) · Radiology · doi:10.1148/radiology.183.3.1584932 · Cited by 163 · cited 1×
“Noninvasive assessments of blood flow and distensibility in the pulmonary arteries can be made [9–11], as well as estimates of stroke volume and cardiac output [10].”
BackgroundBoxt, L. M., Katz, J. K., Kolb, T. J., Czegledy, F. P., & Barst, R. J. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90611-p · Cited by 147 · cited 1×
“It has been successfully used to quantify ventricular volumes and estimate ventricular mass in both normal and PAHT subjects and normal ranges have been established [5–8].”
MethodTorbicki, A., Skwarski, K. M., Hawryłkiewicz, I., Pasierski, T., Miśkiewicz, Z., & Zielinski, J. (1989) · European Respiratory Journal · doi:10.1183/09031936.93.02090856 · Cited by 82 · cited 2×
“Secondly, it depends upon the presence of detectable tricuspid regurgitation and has a significant failure rate in some patient groups [3].”
BackgroundBellenger, N. G., MARCUS, N. J., Davies, C., Yacoub, M. H., Banner, N. R., & Pennell, D. J. (2000) · The Journal of Heart and Lung Transplantation · doi:10.1016/s1053-2498(00)00079-6 · Cited by 75 · cited 9×
“All the values for LVM fell within the normal ranges suggested recently by LORENZ et al. [5] however only three of the seven subjects without pulmonary hypertension at rest fell within the suggested normal range for right RVM.”
BackgroundInfluentialMRI evaluation of right ventricular pressure overload in chronic obstructive pulmonary disease
Marcus, J. T., Noordegraaf, A. V., VRIES, P. M. J. M. D., van Rossum, A. C., Roseboom, B., Heethaar, R. M., & Postmus, P. E. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080502 · Cited by 53 · cited 1×
“[21].”
MRI complements standard assessment of right ventricular function after lung transplantation
Frist, W. H., Lorenz, C. H., Walker, E. S., Loyd, J. E., Stewart, J. R., Graham, T. P., Pearlstein, D. P., Key, S. P., & Merrill, W. H. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00365-r · Cited by 42 · cited 1×
“Changes in right ventricular mass (RVM), function and pulmonary artery blood flow have been observed following lung transplantation [12–15] and MRI has been shown to be far more accurate than ECHO in monitoring changes in left ventricular mass (LVM) [16].”
Background
Cited by
van Wolferen, S. A., Marcus, J. T., Boonstra, A., Marques, K. M. J., Bronzwaer, J. G. F., Spreeuwenberg, M. D., Postmus, P. E., & Vonk-Noordegraaf, A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehl477 · Cited by 753
Pulmonary Arterial Hypertension
McLaughlin, V. V., & McGoon, M. D. (2006) · Circulation · doi:10.1161/circulationaha.104.503540 · Cited by 664
Champion, H. C., Michelakis, E. D., & Hassoun, P. M. (2009) · Circulation · doi:10.1161/circulationaha.106.674028 · Cited by 468
The right ventricle in pulmonary hypertension
Chin, K. M., Kim, N. H. S., & Rubin, L. J. (2005) · Coronary Artery Disease · doi:10.1097/00019501-200502000-00003 · Cited by 429
Right ventricular reverse remodelling after balloon pulmonary angioplasty
Fukui, S., Ogo, T., Morita, Y., Tsuji, A., Tateishi, E., Ozaki, K., Sanda, Y., Fukuda, T., Yasuda, S., Ogawa, H., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00012914 · Cited by 238
Metadata
- Authors
- Saba, T. S., Foster, J., Cockburn, M., Cowan, M., & Peacock, A. J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-12
- Volume
- 20
- Issue
- 6
- Pages
- 1519-1524
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2122189467
- Cited by
- 187
- References
- 10
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.