Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study assessed the accuracy of a cardiorespiratory monitoring device versus polysomnography for the diagnosis of suspected sleep apnoea/hypoponea syndrome (SAS). A total of 86 patients (89% male, mean age 52 yrs) that had been referred to a sleep laboratory with a clinical diagnosis of SAS underwent cardiorespiratory polygraphy in an unattended mode using an ambulatory device (MERLIN). Analysis was carried out both automatically and manually. Conventional overnight full-channel polysomnography was performed simultaneously. Valid polygraphical recordings were obtained from 79 patients. The mean±sd apnoea/hypopnoea index (AHI) was 34.4±29.2. The results obtained with manual scoring were superior to automatic scoring for all AHI thresholds. For an AHI of ≥5, which is diagnostic SAS, the optimum cut-off value for the manual respiratory event index was 6.7 and the cardiorespiratory monitoring device had 97.1% sensitivity and 90.9% specificity. Correct classification according to the different cut-off points obtained via polysomnography and the corresponding cut-off points in the MERLIN manual index were confirmed in 90–96% of patients. The MERLIN device is a useful diagnostic approach for the initial assessment of adult patients with clinical suspicion of sleep apnoea/hypopnoea syndrome. Manual scoring is clearly better than automatic scoring in terms of agreement with the apnoea/hypopnoea index and to discern patients with sleep apnoea/hypopnoea syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Nieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Sasayama, S., Izumi, T., Seino, Y., Ueshima, K., Asanoi, H., & for The CHF-HOT Study Group (2006) · Circulation Journal · doi:10.1253/circj.70.1 · Cited by 183
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
“night-to-night variability, and better sleep quality and stability, resulting in fewer obstructive events”
BackgroundValidation of a Portable Monitoring System for the Diagnosis of Obstructive Sleep Apnea Syndrome
Santos-Silva, R., Sartori, D. E., Truksinas, V., Truksinas, E., Alonso, F. F. F. D., Tufik, S., & Bittencourt, L. R. A. (2009) · Sleep · doi:10.1093/sleep/32.5.629 · Cited by 142
Metadata
- Authors
- Calleja, J. M., Esnaola, S., Rubio, R., & Durán, J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2002-12
- Volume
- 20
- Issue
- 6
- Pages
- 1505-1510
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2120525466
- Cited by
- 89
- References
- 2
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea. https://app.cochat.ai/papers/10.1183/09031936.02.00297402
- The paper
- Calleja, J. M., Esnaola, S., Rubio, R., & Durán, J. (2002). Comparison of a cardiorespiratory device versus polysomnography for diagnosis of sleep apnoea. European Respiratory Journal. https://doi.org/10.1183/09031936.02.00297402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.