The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome
Open accessAbstract
Waiting times for hospital-based monitoring of the obstructive sleep apnoea/hypopnoea syndrome (OSAHS) are rising. This study tested whether Embletta, a new portable device, may accurately diagnose OSAHS at home. A synchronous comparison to polysomnography was performed in 40 patients and a comparison of home Embletta studies with in-laboratory polysomnography was performed in 61 patients. In the synchronous study, the mean difference (polysomnography–Embletta) in apnoeas+hypopnoeas (A+H)·h−1 in bed was 2·h−1. In comparison to the apnoea/hypopnoea index (AHI)·h−1 slept, the Embletta (A+H)·h−1 in bed differed by 8·h−1. These data were used to construct diagnostic categories in symptomatic patients from their Embletta results: “OSAHS” (≥20 (A+H)·h−1 in bed), “possible OSAHS” (10–20 (A+H)·h−1 in bed) or “not OSAHS” (<10 (A+H)·h−1 in bed). In the home study, the mean difference in (A+H)·h−1 in bed was 3·h−1. In comparison to the polysomnographic AHI·h−1 slept, the Embletta (A+H)·h−1 in bed differed by 6±14·h−1. Using the above classification, all nine patients categorised as not OSAHS had AHI <15·h−1 slept on polysomnography and all 23 with OSAHS on Embletta had an AHI ≥15 on polysomnography, but 18 patients fell into the possible OSAHS category potentially requiring further investigation and 11 home studies failed. Most patients were satisfactorily classified by home Embletta studies but 29 out of 61 required further investigation. The study suggested a 42% saving in diagnostic costs over polysomnography if this approach were adopted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,638
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183
McNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Self-citationNieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
The Association between Sleep Apnea and the Risk of Traffic Accidents
Terán-Santos, J., Jimenez-Gomez, A., & Cordero-Guevara, J. (1999) · New England Journal of Medicine · doi:10.1056/nejm199903183401104 · Cited by 1,255
Engleman, H. M., Martin, S. E., Douglas, N. J., & Deary, I. J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91522-9 · Cited by 592
Self-citationClinical value of polysomnography
Douglas, N. J., Thomas, S., & Jan, M. A. (1992) · The Lancet · doi:10.1016/0140-6736(92)91660-z · Cited by 385
Self-citationThe Medical Cost of Undiagnosed Sleep Apnea
Kapur, V., Blough, D. K., Sandblom, R. E., Hert, R., de Maine, J. B., Sullivan, S. D., & Psaty, B. M. (1999) · Sleep · doi:10.1093/sleep/22.6.749 · Cited by 384
Engleman, H. M., Martin, S. E., Kingshott, R. N., Mackay, T. W., Deary, I. J., & Douglas, N. J. (1998) · Thorax · doi:10.1136/thx.53.5.341 · Cited by 308
Self-citation
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Post-Stroke Fatigue: Epidemiology, Clinical Characteristics and Treatment
Acciarresi, M., Bogousslavsky, J., & Paciaroni, M. (2014) · European Neurology · doi:10.1159/000363763 · Cited by 1,417
Oldenburg, O., Lamp, B., Faber, L., Teschler, H., Horstkotte, D., & Töpfer, V. (2007) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2006.08.003 · Cited by 756
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Metadata
- Authors
- Dingli, K., Coleman, E. L., Vennelle, M., Finch, S. P., Wraith, P. K., Mackay, T. W., & Douglas, N. J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2003-02
- Volume
- 21
- Issue
- 2
- Pages
- 253-259
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2139865439
- Cited by
- 287
- References
- 16
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.03.00298103
- The paper
- Dingli, K., Coleman, E. L., Vennelle, M., Finch, S. P., Wraith, P. K., Mackay, T. W., & Douglas, N. J. (2003). Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.03.00298103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.