Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome

Open access
Dingli, K., Coleman, E.L., Vennelle, M., Finch, S.P., Wraith, P.K., Mackay, T.W., Douglas, N.J. · 2003 · European Respiratory Journal

Abstract

Waiting times for hospital-based monitoring of the obstructive sleep apnoea/hypopnoea syndrome (OSAHS) are rising. This study tested whether Embletta, a new portable device, may accurately diagnose OSAHS at home. A synchronous comparison to polysomnography was performed in 40 patients and a comparison of home Embletta studies with in-laboratory polysomnography was performed in 61 patients. In the synchronous study, the mean difference (polysomnography–Embletta) in apnoeas+hypopnoeas (A+H)·h−1 in bed was 2·h−1. In comparison to the apnoea/hypopnoea index (AHI)·h−1 slept, the Embletta (A+H)·h−1 in bed differed by 8·h−1. These data were used to construct diagnostic categories in symptomatic patients from their Embletta results: “OSAHS” (≥20 (A+H)·h−1 in bed), “possible OSAHS” (10–20 (A+H)·h−1 in bed) or “not OSAHS” (<10 (A+H)·h−1 in bed). In the home study, the mean difference in (A+H)·h−1 in bed was 3·h−1. In comparison to the polysomnographic AHI·h−1 slept, the Embletta (A+H)·h−1 in bed differed by 6±14·h−1. Using the above classification, all nine patients categorised as not OSAHS had AHI <15·h−1 slept on polysomnography and all 23 with OSAHS on Embletta had an AHI ≥15 on polysomnography, but 18 patients fell into the possible OSAHS category potentially requiring further investigation and 11 home studies failed. Most patients were satisfactorily classified by home Embletta studies but 29 out of 61 required further investigation. The study suggested a 42% saving in diagnostic costs over polysomnography if this approach were adopted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.03.00298103

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

See all 287

Metadata

Authors
Dingli, K., Coleman, E. L., Vennelle, M., Finch, S. P., Wraith, P. K., Mackay, T. W., & Douglas, N. J.
Venue
European Respiratory Journal
Published
2003-02
Volume
21
Issue
2
Pages
253-259
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2139865439
Cited by
287
References
16
FWCI
7.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.03.00298103
The paper
Dingli, K., Coleman, E. L., Vennelle, M., Finch, S. P., Wraith, P. K., Mackay, T. W., & Douglas, N. J. (2003). Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.03.00298103