Evaluation of a portable device for diagnosing the sleep apnoea/hypopnoea syndrome
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Waiting times for hospital-based monitoring of the obstructive sleep apnoea/hypopnoea syndrome (OSAHS) are rising. This study tested whether Embletta, a new portable device, may accurately diagnose OSAHS at home. A synchronous comparison to polysomnography was performed in 40 patients and a comparison of home Embletta studies with in-laboratory polysomnography was performed in 61 patients. In the synchronous study, the mean difference (polysomnography–Embletta) in apnoeas+hypopnoeas (A+H)·h−1 in bed was 2·h−1. In comparison to the apnoea/hypopnoea index (AHI)·h−1 slept, the Embletta (A+H)·h−1 in bed differed by 8·h−1. These data were used to construct diagnostic categories in symptomatic patients from their Embletta results: “OSAHS” (≥20 (A+H)·h−1 in bed), “possible OSAHS” (10–20 (A+H)·h−1 in bed) or “not OSAHS” (<10 (A+H)·h−1 in bed). In the home study, the mean difference in (A+H)·h−1 in bed was 3·h−1. In comparison to the polysomnographic AHI·h−1 slept, the Embletta (A+H)·h−1 in bed differed by 6±14·h−1. Using the above classification, all nine patients categorised as not OSAHS had AHI <15·h−1 slept on polysomnography and all 23 with OSAHS on Embletta had an AHI ≥15 on polysomnography, but 18 patients fell into the possible OSAHS category potentially requiring further investigation and 11 home studies failed. Most patients were satisfactorily classified by home Embletta studies but 29 out of 61 required further investigation. The study suggested a 42% saving in diagnostic costs over polysomnography if this approach were adopted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
The Occurrence of Sleep-Disordered Breathing among Middle-Aged Adults
Young, T., Palta, M., Dempsey, J., Skatrud, J., Weber, S., & Badr, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199304293281704 · Cited by 10,183 · cited 1×
“Obstructive sleep apnoea/hypopnoea syndrome (OSAHS) affects 1–4% of the population [1] causing daytime sleepiness, impaired work performance, road accidents [2] and hypertension [3].”
BackgroundMcNicholas, W. T., Strohl, K. P., White, D. P., Levy, P. A., Schmidt, W., Wheatley, J. R., Redline, S. S., Carley, D. W., Buysse, D. J., Young, T. B., et al. (1999) · PubMed · Cited by 3,665
Self-citationNieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
The Association between Sleep Apnea and the Risk of Traffic Accidents
Terán-Santos, J., Jimenez-Gomez, A., & Cordero-Guevara, J. (1999) · New England Journal of Medicine · doi:10.1056/nejm199903183401104 · Cited by 1,255
Engleman, H. M., Martin, S. E., Douglas, N. J., & Deary, I. J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91522-9 · Cited by 592 · cited 1×
“The current authors used a conservative cut of an AHI of 15?h plus symptoms, as there is robust evidence for the benefits of continuous positive airway pressure (CPAP) therapy in symptomatic patients with AHI ¢15?h [13, 14].”
MethodSelf-citationClinical value of polysomnography
Douglas, N. J., Thomas, S., & Jan, M. A. (1992) · The Lancet · doi:10.1016/0140-6736(92)91660-z · Cited by 385
Self-citationThe Medical Cost of Undiagnosed Sleep Apnea
Kapur, V., Blough, D. K., Sandblom, R. E., Hert, R., de Maine, J. B., Sullivan, S. D., & Psaty, B. M. (1999) · Sleep · doi:10.1093/sleep/22.6.749 · Cited by 384 · cited 1×
“However, the limited number of sleep centres and beds often results in long waiting lists for diagnosis and treatment of OSAHS and there is evidence that untreated sleep apnoea is both deleterious to the patient and expensive to the healthcare budget [5, 6].”
BackgroundEngleman, H. M., Martin, S. E., Kingshott, R. N., Mackay, T. W., Deary, I. J., & Douglas, N. J. (1998) · Thorax · doi:10.1136/thx.53.5.341 · Cited by 308
Self-citation
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Post-Stroke Fatigue: Epidemiology, Clinical Characteristics and Treatment
Acciarresi, M., Bogousslavsky, J., & Paciaroni, M. (2014) · European Neurology · doi:10.1159/000363763 · Cited by 1,417
Oldenburg, O., Lamp, B., Faber, L., Teschler, H., Horstkotte, D., & Töpfer, V. (2007) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2006.08.003 · Cited by 756
“Mean difference in AHI was 2±5/ h [22].”
BackgroundMethodQaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Obstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Sleep-Disordered Breathing in Heart Failure with Normal Left Ventricular Ejection Fraction
Bitter, T., Faber, L., Hering, D., Langer, C., Horstkotte, D., & Oldenburg, O. (2009) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp057 · Cited by 292
Bitter, T., Westerheide, N., Prinz, C., Hossain, M. S., Vogt, J., Langer, C., Horstkotte, D., & Oldenburg, O. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq327 · Cited by 284
Assessment of sleep health in patients with rheumatic disease
Taylor-Gjevre, R., Gjevre, J. A., Skomro, R., & Nair, B. V. (2011) · International Journal of Clinical Rheumatology · doi:10.2217/ijr.11.6 · Cited by 187
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
Validation of a Portable Monitoring System for the Diagnosis of Obstructive Sleep Apnea Syndrome
Santos-Silva, R., Sartori, D. E., Truksinas, V., Truksinas, E., Alonso, F. F. F. D., Tufik, S., & Bittencourt, L. R. A. (2009) · Sleep · doi:10.1093/sleep/32.5.629 · Cited by 142
Validation of Watch-PAT-200 Against Polysomnography During Pregnancy
O’Brien, L. M., Bullough, A. S., Shelgikar, A. V., Chames, M. C., Armitage, R., & Chervin, R. D. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1916 · Cited by 133
“Low rejection rates have been found in other studies with Watch-PAT, 7 unlike unattended PSG where the rejection rate is typically much higher, 37,38 up to one-third of studies performed.”
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
Johnson, D. A., Guo, N., Rueschman, M., Wang, R., Wilson, J. G., & Redline, S. (2018) · Sleep · doi:10.1093/sleep/zsy154 · Cited by 126
“OSA was assessed with a validated type 3 home sleep apnea device (Embletta-Gold device; Embla, Broomfield, CO) [21, 22], recording nasal pressure (measuring airflow); thoracic and abdominal inductance plethysmography; finger pulse oximetry; body position; and ECG.”
MethodValidation of a Self-Applied Unattended Monitor for Sleep Disordered Breathing
Ayappa, I., Norman, R. G., Seelall, V., & Rapoport, D. M. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27075 · Cited by 125
Walia, H. K., Li, H., Rueschman, M., Bhatt, D. L., Patel, S. R., Quan, S. F., Gottlieb, D. J., Punjabi, N. M., Redline, S., & Mehra, R. (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3946 · Cited by 104
“Subjects who met the inclusion criteria underwent overnight type III sleep testing 16 (Embletta-Gold, Embla, Broomfield, CO USA); those with an apnea hypopnea index of 15-50 events/h were considered eligible and were included in the study.”
An Economic Evaluation of Home Versus Laboratory-Based Diagnosis of Obstructive Sleep Apnea
Kim, R. D., Kapur, V. K., Redline-Bruch, J., Rueschman, M., Auckley, D. H., Benca, R. M., Foldvary-Schafer, N. R., Iber, C., Zee, P. C., Rosen, C. L., et al. (2015) · Sleep · doi:10.5665/sleep.4804 · Cited by 105
Deutsch, P. A., Simmons, M. S., & Wallace, J. M. (2006) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.26508 · Cited by 103
Thunström, E., Manhem, K., Rosengren, A., & Peker, Y. (2016) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201505-0998oc · Cited by 91
Association Between Sleep Apnea and Blood Pressure Control Among Blacks: Jackson Heart Sleep Study
Johnson, D. A., Thomas, S. J., Abdalla, M., Guo, N., Yano, Y., Rueschman, M., Tanner, R. M., Mittleman, M. A., Calhoun, D. A., Wilson, J. G., et al. (2019) · Circulation · doi:10.1161/circulationaha.118.036675 · Cited by 81
BITTER, T., NÖLKER, G., VOGT, J., PRINZ, C., HORSTKOTTE, D., & OLDENBURG, O. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02148.x · Cited by 68
“LAD, mm, median (quartiles) 46 (45, 49)∗∗ 45 (42, 56) 42 (36, 44) Laboratory measurement NT-proBNP, pg/mL, median (quartiles) 249 (88, 289) 204 (77, 332) 177 (116, 296) Hb, g/dL 14.”
A Randomized Controlled Study to Examine the Effect of a Lifestyle Modification Program in OSA
Ng, S. S. S., Chan, R. S. M., Woo, J., Chan, T.-O., Cheung, B. H. K., Sea, M. M. M., To, K.-W., Chan, K. K. P., Ngai, J., Yip, W.-H., et al. (2015) · Chest · doi:10.1378/chest.14-3016 · Cited by 62
Elevated Posture for the Management of Obstructive Sleep Apnea
Skinner, M. A., Kingshott, R. N., Jones, D. R., Homan, S. D. R., & Taylor, D. R. (2004) · Sleep and Breathing · doi:10.1055/s-2004-860896 · Cited by 63
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernández-Blasco, L., Monasterio, C., Alonso-Fernandez, A., Chiner, E., Vázquez-Polo, F.-J., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00186811 · Cited by 44
Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
Nakano, H., Tanigawa, T., Ohnishi, Y., Uemori, H., Senzaki, K., Furukawa, T., & Nishima, S. (2008) · European Respiratory Journal · doi:10.1183/09031936.00130907 · Cited by 43
Severity of OSAS, CPAP and cardiovascular events: A follow‐up study
Baratta, F., Pastori, D., Fabiani, M., Fabiani, V., Ceci, F., Lillo, R., Lolli, V., Brunori, M., Pannitteri, G., Cravotto, E., et al. (2018) · European Journal of Clinical Investigation · doi:10.1111/eci.12908 · Cited by 40
“Unattended home polysomnography should be considered as a major limitation of this study, although an excellent correlation between the results of attended polysomnography and home monitoring has been demonstrated.(35) Indeed, polysomnography and home sleep tests use the same respiratory equipment, pulse oximetry equi…”
ResultGjevre, J., Taylor-Gjevre, R., Skomro, R., Reid, J., Fenton, M., & Cotton, D. (2011) · Canadian Respiratory Journal · doi:10.1155/2011/408091 · Cited by 40
“It is important to establish comparable diagnostic accuracy; however, studies performed to date have focused on OSA in predominantly male populations (9,10).”
BackgroundMethodResultThe Utility of Single-Channel Nasal Airflow Pressure Transducer in the Diagnosis Of OSA at Home
Rofail, L. M., Wong, K. K. H., Unger, G., Marks, G. B., & Grunstein, R. R. (2010) · Sleep · doi:10.1093/sleep/33.8.1097 · Cited by 40
A Comprehensive Evaluation of a Two-Channel Portable Monitor to “Rule in” Obstructive Sleep Apnea
Ward, K. L., McArdle, N., James, A., Bremner, A. P., Simpson, L., Cooper, M. N., Palmer, L. J., Fedson, A. C., Mukherjee, S., & Hillman, D. R. (2015) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.4600 · Cited by 39
Polese, J. F., Santos-Silva, R., de Oliveira Ferrari, P. M., Sartori, D. E., Tufik, S., & Bittencourt, L. (2013) · Sleep and Breathing · doi:10.1007/s11325-012-0742-y · Cited by 32
Masdeu, M. J., Ayappa, I., Hwang, D., Mooney, A. M., & Rapoport, D. M. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27710 · Cited by 25
Chernyshev, O. Y., McCarty, D. E., Moul, D. E., Liendo, C., Caldito, G. C., Munjampalli, S. K., Kelley, R., & Chesson Jr, A. L. (2015) · Nature and Science of Sleep · doi:10.2147/nss.s85780 · Cited by 23
“The use of OCST devices for diagnosis of OSA may reduce costs by as much as 42%, when compared with conventional polysomnography (PSG).(42) Optimal validation studies comparing two techniques (such as OCST and PSG) involve simultaneous testing of both devices on the same subject, to eliminate confounding due to night-…”
Home- vs. Laboratory-based management of OSA: an economic review
He, K., Kim, R., & Kapur, V. K. (2016) · Current Sleep Medicine Reports · doi:10.1007/s40675-016-0042-3 · Cited by 11
Patel, M. R., Alexander, T. H., & Davidson, T. M. (2007) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2007.01.005 · Cited by 8
Metadata
- Authors
- Dingli, K., Coleman, E. L., Vennelle, M., Finch, S. P., Wraith, P. K., Mackay, T. W., & Douglas, N. J.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2003-02
- Volume
- 21
- Issue
- 2
- Pages
- 253-259
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2139865439
- Cited by
- 287
- References
- 16
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.