Effects of mandibular advancement on airway curvature and obstructive sleep apnoea severity
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In a curved tube, the amount of airflow appears to be influenced by the amount of curvature. The purpose of this study was to investigate changes in obstructive sleep apnoea (OSA) severity and awake velopharyngeal curvature in response to an anteriorly titrated mandibular position in 20 male OSA patients. Baseline supine cephalometry was obtained before the initial insertion of a titratable oral appliance and follow-up supine cephalometry was undertaken after titration of the mandibular position with the appliance in place. The mean apnoea/hypopnea index (AHI) before treatment (31.6±13.0 events·h−1) was significantly reduced (9.8±7.4 events·h−1) after titration of the mandibular position in all 20 patients. There was a significant increase in the anteroposterior calibre and the radius of the curvature of the anterior wall of the velopharynx in 14 good responders who exhibited an AHI reduction to ≤15. Similar observations were not found in six poor responders. To conclude, an anteriorly titrated mandibular position reduced obstructive sleep apnoea severity, enlarged the velopharynx and diminished the curvature of the anterior velopharyngeal wall in good responders. It is proposed that this change in the upper airway curvature associated with mandibular advancement may effect obstructive sleep apnoea severity through its effect on airflow dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized, Controlled Study of a Mandibular Advancement Splint for Obstructive Sleep Apnea
MEHTA, A., QIAN, J., PETOCZ, P., DARENDELILER, M. A., & CISTULLI, P. A. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.2004213 · Cited by 514
Ferguson, K. A., Ono, T., Lowe, A. A., al-Majed, S., Love, L. L., & Fleetham, J. A. (1997) · Thorax · doi:10.1136/thx.52.4.362 · Cited by 391
Self-citationA role of pharyngeal length in obstructive sleep apnea patients
Pae, E.-K., Lowe, A. A., & Fleetham, J. A. (1997) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/s0889-5406(97)70296-8 · Cited by 97
Self-citation
Cited by
The effect of mandibular advancement on upper airway structure in obstructive sleep apnoea
Chan, A. S. L., Sutherland, K., Schwab, R. J., Zeng, B., Petocz, P., Lee, R. W. W., Darendeliler, M. A., & Cistulli, P. A. (2010) · Thorax · doi:10.1136/thx.2009.131094 · Cited by 356
Supine position related obstructive sleep apnea in adults: Pathogenesis and treatment
Joosten, S. A., O'Driscoll, D. M., Berger, P. J., & Hamilton, G. S. (2014) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2013.01.005 · Cited by 259
Sleep endoscopy with simulation bite for prediction of oral appliance treatment outcome
Vroegop, A. V. M. T., Vanderveken, O. M., Dieltjens, M., Wouters, K., Saldien, V., Braem, M. J., & Van de heyning, P. H. (2013) · Journal of Sleep Research · doi:10.1111/jsr.12008 · Cited by 172
“The aim is to prevent UA collapse and increase the cross-sectional airway dimensions, and thereby reduce snoring and obstructive sleep apneas (Tsuiki et al., 2004).”
BackgroundHuynh, N. T., Desplats, E., & Almeida, F. R. (2016) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.02.002 · Cited by 171
Self-citationde Almeida, F. R., Lowe, A. A., Sung, J. O., Tsuiki, S., & Otsuka, R. (2006) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.10.001 · Cited by 160
Self-citationNazarali, N., Altalibi, M., Nazarali, S., Major, M. P., Flores-Mir, C., & Major, P. W. (2015) · The European Journal of Orthodontics · doi:10.1093/ejo/cju101 · Cited by 62
Randerath, W., Bauer, M., Blau, A., Fietze, I., Galetke, W., Hein, H., Maurer, J. T., Orth, M., Rasche, K., Ruhle, K.-H., et al. (2006) · Somnologie · doi:10.1111/j.1439-054x.2006.00082.x · Cited by 19
Marcussen, L., Henriksen, J. E., & Thygesen, T. (2015) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2015.02.023 · Cited by 17
“These studies predominantly used cephalometric radiographs, which limits the measurements and subsequent evaluation to two dimensions [17-24].”
MethodElfouly, D., Dumu, E., Madian, A. M., & Eid, F. Y. (2024) · Scientific Reports · doi:10.1038/s41598-024-69717-5 · Cited by 13
“They attributed their findings to the resultant forward mandibular movement, which in consequence, elicits a forward pull on the tongue, hyoid bone, and soft tissues of the oropharynx and laryngopharynx, thus expanding the airway area 43 .”
Background
Metadata
- Authors
- Tsuiki, S., Lowe, A. A., Almeida, F. R., Kawahata, N., & Fleetham, J. A.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-02
- Volume
- 23
- Issue
- 2
- Pages
- 263-268
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2171369430
- Cited by
- 106
- References
- 3
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.