Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The current study investigated the night-to-night variability and diagnostic accuracy of the oxygen desaturation index (ODI), as measured by ambulatory monitoring, in the diagnosis of mild and moderate obstructive sleep apnoea–hypopnoea syndrome. To assess the variability of the ODI, 35 patients were monitored at home during 7 consecutive nights by means of a portable recording device, the MESAM-IV®. The ODI variability factor and the influence of age, body mass index (BMI), alcohol, and body position were assessed. Furthermore, the diagnostic accuracy of the MESAM-IV was measured by comparison with polysomnographical outcomes in 18 patients. During home recording, the median ODI was 10.9 (interquartile range: 5.8–16.1) across the patients. Although the reliability of the ODI was adequate, the probability of placing the patient in the wrong severity category (ODI ≤15 or ODI >15) when only one single recording was taken is 14.4%. ODI variability was not significantly influenced by age, BMI, time spent in a supine position, or mild dosages of alcohol. A good correlation was found between the apnoea–hypopnoea index and the ODI. In conclusion, the findings suggest that the diagnostic accuracy of the MESAM-IV is strong, since the oxygen desaturation index is correlated with the apnoea–hypopnoea index. In most obstructive sleep apnoea–hypopnoea syndrome patients, oxygen desaturation index variability is rather small, and screening could be reliably based on single 1-night recordings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Varying Approaches for Identifying Respiratory Disturbances on Sleep Apnea Assessment
REDLINE, S., KAPUR, V. K., SANDERS, M. H., QUAN, S. F., GOTTLIEB, D. J., RAPOPORT, D. M., BONEKAT, W. H., SMITH, P. L., KILEY, J. P., & IBER, C. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.2.9904031 · Cited by 225
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Lifestyle Intervention with Weight Reduction: First-line Treatment in Mild Obstructive Sleep Apnea
Tuomilehto, H. P. I., Seppä, J. M., Partinen, M. M., Peltonen, M., Gylling, H., Tuomilehto, J. O. I., Vanninen, E. J., Kokkarinen, J., Sahlman, J. K., Martikainen, T., et al. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200805-669oc · Cited by 439
Gali, B., Whalen, F. X., Schroeder, D. R., Gay, P. C., & Plevak, D. J. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819b5d70 · Cited by 264
Aron-Wisnewsky, J., Minville, C., Tordjman, J., Lévy, P., Bouillot, J.-L., Basdevant, A., Bedossa, P., Clément, K., & Pépin, J.-L. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2011.04.022 · Cited by 255
Ahmadi, N., Shapiro, G. K., Chung, S. A., & Shapiro, C. M. (2009) · Sleep and Breathing · doi:10.1007/s11325-008-0234-2 · Cited by 134
“In addition, Fieze and colleagues [16] have reported that the oxygen desaturation levels in about 14% of their cases showed significant night-to-night variability.”
Background
Metadata
- Authors
- Fietze, I., Dingli, K., Diefenbach, K., Douglas, N. J., Glos, M., Tallafuss, M., Terhalle, W., & Witt, C.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2004-12
- Volume
- 24
- Issue
- 6
- Pages
- 987-993
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2100961644
- Cited by
- 88
- References
- 1
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome. https://app.cochat.ai/papers/10.1183/09031936.04.00100203
- The paper
- Fietze, I., Dingli, K., Diefenbach, K., Douglas, N. J., Glos, M., Tallafuss, M., Terhalle, W., & Witt, C. (2004). Night-to-night variation of the oxygen desaturation index in sleep apnoea syndrome. European Respiratory Journal. https://doi.org/10.1183/09031936.04.00100203
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.