Non-invasive mechanical ventilation for cystic fibrosis patients--a potential bridge to transplantation
Open accessThe DOI matches its Crossref record.
Abstract
The case histories of six cystic fibrosis patients awaiting heart-lung transplantation are reviewed. They all deteriorated with severe hypoxia and hypercapnia before donor organs became available. Nasal intermittent positive pressure ventilation was used in preference to conventional ventilation with excellent results in four patients. There were no episodes of hypotension or toxaemia and the patients were in a stable condition at the time of surgery and made an excellent post-operative recovery. The patients who were transplanted and the patient who died, for whom suitable donor organs did not become available, probably had a more comfortable time than they would have done if treated with conventional ventilation. This method of ventilation appears to be a useful bridge to transplantation when a patient suddenly deteriorates. It gives them a chance of survival for a few more days or even weeks during which time an urgent search for donor organs can be made. This is also a very cost effective method of ventilation and does not encroach on conventional Intensive Care Unit (ICU) facilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bott, J., Carroll, M. P., Conway, J. H., Keilty, S. E. J., Ward, E. M., Brown, A. M., Paul, E. A., Elliott, M. W., Godfrey, R. C., Wedzicha, J. A., et al. (1993) · The Lancet · doi:10.1016/0140-6736(93)90696-e · Cited by 849
Sleep-disordered Breathing in Children
MARCUS, C. L. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2008171 · Cited by 666
Non-invasive ventilation in acute respiratory failure
(2002) · Thorax · doi:10.1136/thorax.57.3.192 · Cited by 652
Yankaskas, J. R., Marshall, B. C., Sufian, B., Simon, R. H., & Rodman, D. (2004) · Chest · doi:10.1378/chest.125.1_suppl.1s · Cited by 579
Zaroff, J. G., Rosengard, B. R., Armstrong, W. F., Babcock, W. D., D’Alessandro, A., Dec, G. W., Edwards, N. M., Higgins, R. S., Jeevanandum, V., Kauffman, M., et al. (2002) · Circulation · doi:10.1161/01.cir.0000025587.40373.75 · Cited by 495
Noninvasive Positive Pressure Ventilation Via Face Mask
Meduri, G. U., Turner, R. E., Abou-Shala, N., Wunderink, R., & Tolley, E. (1996) · Chest · doi:10.1378/chest.109.1.179 · Cited by 482
BTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
Simonds, A. K., & Elliott, M. W. (1995) · Thorax · doi:10.1136/thx.50.6.604 · Cited by 388
Mechanical Ventilation Beyond the Intensive Care Unit
Make, B. J., Hill, N. S., Goldberg, A. I., Bach, J. R., Criner, G. J., Dunne, P. E., Gilmartin, M. E., Heffner, J. E., Kacmarek, R., Keens, T. G., et al. (1998) · Chest · doi:10.1378/chest.113.5_supplement.289s · Cited by 221
NONINVASIVE POSITIVE-PRESSURE VENTILATION IN PATIENTS WITH ACUTE RESPIRATORY FAILURE
Meduri, G. U. (1996) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(05)70330-0 · Cited by 160
The growing role of noninvasive ventilation in patients requiring prolonged mechanical ventilation
Hess, D. R. (2012) · Respiratory Care · doi:10.4187/respcare.01692 · Cited by 59
Metadata
- Authors
- Hodson, M., Madden, B., Steven, M., Tsang, V., & Yacoub, M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1991-05-01
- Volume
- 4
- Issue
- 5
- Pages
- 524-527
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1900058932
- Cited by
- 209
- References
- 0
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.