Force-frequency relationships of in vivo human and in vitro rat diaphragm using paired stimuli
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Supramaximal stimuli, with time intervals of 100 ms (10 Hz) to 10 ms (100 Hz), were delivered in pairs to the phrenic nerves, bilaterally, in five seated normal subjects, while transdiaphragmatic pressure swings (Pdi,s) were recorded at relaxed end-expiratory lung volume with airways closed. In fresh diaphragms, Pdi,s increased between 10-20 Hz and reached a plateau between 20-30 Hz. Diaphragmatic fatigue decreased Pdi,s at all frequencies. Pdi,s was assumed to be the sum of two successive responses (T1+T2), T1 being constant at any frequency and equal to a single twitch, T2 being obtained by subtraction. We found that T2 amplitude, which was significantly reduced after fatigue, was fully returned to normal after 15 min rest at high, not at low, stimulation frequencies. The ratio of T2 at 10 Hz over 100 Hz (T2(10/100)) thus decreased from 1.33 +/- 0.05 before fatigue to 0.97 +/- 0.12 after fatigue, and to 0.81 +/- 0.06 after 15 min rest. Similar results were obtained in isolated rat diaphragmatic strips stimulated and fatigued in vitro, from which we found a highly linear relationship (r = 0.94, p < 0.001) between the ratio of T2(10/100) and that of tetanic force at 10 Hz over 100 Hz (P10/100). We conclude that phrenic nerve paired twitches provide similar information when obtained from phrenic tetanic stimulation in terms of diaphragmatic contractility, and the decrease in T2(10/100) ratio indicates diaphragm low frequency fatigue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic properties of mammalian skeletal muscles.
Close, R. I. (1972) · Physiological Reviews · doi:10.1152/physrev.1972.52.1.129 · Cited by 1,890
Maximal respiratory pressures: normal values and relationship to age and sex.
Black, L. F., & Hyatt, R. E. (1969) · PubMed · doi:10.1164/arrd.1969.99.5.696 · Cited by 1,877
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Consequences of exercise-induced respiratory muscle work
Dempsey, J. A., Romer, L., Rodman, J., Miller, J., & Smith, C. (2006) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2005.12.015 · Cited by 398
“We quantified the effects of inspiratory muscle work on exercise-induced quadriceps muscle fatigue using supra-maximal stimulation of the femoral nerve with a double twitch stimulation technique (Yan et al., 1993; Polkey et al., 1996).”
MethodAmann, M., Eldridge, M. W., Lovering, A. T., Stickland, M. K., Pegelow, D. F., & Dempsey, J. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.113936 · Cited by 390
Effect of inspiratory muscle work on peripheral fatigue of locomotor muscles in healthy humans
Romer, L. M., Lovering, A. T., Haverkamp, H. C., Pegelow, D. F., & Dempsey, J. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2005.099697 · Cited by 225
Effects of arterial oxygen content on peripheral locomotor muscle fatigue
Amann, M., Romer, L. M., Pegelow, D. F., Jacques, A. J., Hess, C. J., & Dempsey, J. A. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01596.2005 · Cited by 185
“We used single (1-Hz) and paired stimuli [interstimulus intervals 100 ms ( 10 Hz), 50 ms ( 20 Hz), and 10 ms ( 100 Hz)] to discriminate between low- and high-frequency fatigue (48, 64).”
Method
Metadata
- Authors
- Yan, S., Gauthier, A., Similowski, T., Faltus, R., Macklem, P., & Bellemare, F.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1993-02-01
- Volume
- 6
- Issue
- 2
- Pages
- 211-218
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W1957461011
- Cited by
- 39
- References
- 2
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.