CoChat

Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period

Open access
Verschelden, P, Cartier, A, L'Archeveque, J, Trudeau, C, Malo, JL · 1996 · European Respiratory Journal
Cited by 122

The DOI matches its Crossref record.

Abstract

Serial peak expiratory flow (PEF) assessment has been proposed in the clinical evaluation of asthma. In subjects attending the asthma clinic of a tertiary care hospital, we wanted to assess: 1) compliance in performing PEF; and 2) accuracy of a PEF-diary. Twenty adult asthmatic subjects, all using inhaled steroids, were asked to assess their PEF in the morning and evening with a VMX instrument (Clement Clarke Int., Colombus, OH, USA). This instrument, which incorporates a standard mini-Wright peak flow meter, stores PEF data on a computer chip. Subjects were not informed that the values were being stored. The mean duration of PEF monitoring was 89 days (range 44-131 days). For the total of 20 subjects, it was estimated that 3,482 values should have been written down and stored on the VMX computer chip. Whilst 1,897 values (54%) were written down, only 1,533 (44%) were stored, 425 values being invented. Morning and evening values were stored on 34% of days; and values were stored at least once a day on 55% of days. The values written down corresponded precisely to stored values 90% of the time, and were within +/- 20 L 94% of the time. We conclude that: 1) compliance with daily peak expiratory flow assessments is generally poor in chronic stable asthmatic subjects assessed on two visits separated by a 3 month period; and 2) a substantial percentage of values (22%) is invented. The unsatisfactory compliance with peak expiratory flow monitoring in this group of asthmatics on inhaled steroids underlines the need for similar studies on peak expiratory flow monitoring as part of an action treatment plan, and in more severe and brittle asthmatics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.96.09050880

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 122

Metadata

Authors
Verschelden, P., Cartier, A., L'Archeveque, J., Trudeau, C., & Malo, J.
Venue
European Respiratory Journal
Published
1996-05-01
Volume
9
Issue
5
Pages
880-885
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2100891719
Cited by
122
References
0
FWCI
4.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period. https://app.cochat.ai/papers/10.1183/09031936.96.09050880
The paper
Verschelden, P., Cartier, A., L'Archeveque, J., Trudeau, C., & Malo, J. (1996). Compliance with and accuracy of daily self-assessment of peak expiratory flows (PEF) in asthmatic subjects over a three month period. European Respiratory Journal. https://doi.org/10.1183/09031936.96.09050880

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.