Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This study evaluated the accuracy of a portable recording device (MESAM IV) in identifying obstructive sleep apnoea (OSA). The MESAM IV system measures arterial oxygen saturation (Sa,O2), heart rate, snoring sounds and body position, and allows both automatic and manual scoring of the recordings. Nocturnal polysomnography and MESAM IV recordings were performed simultaneously in 150 patients with suspected OSA, and were analysed blindly by a different observer. Patients with an apnoea-hypopnoea index (AHI) greater than or equal to 10 were diagnosed as having OSA. In the evaluation of the discriminatory ability of MESAM IV scores, the cut-off point was set to minimize first the exclusion of truly diseased patients (i.e. false-negative interpretations), and then confirmation of nondiseased subjects (i.e. false-positives). When used as an exclusion test, the portable device reached a sensitivity of 0.98 and a specificity of 0.78; as a confirmation test, these values were 0.69 and 0.97, respectively. These results were achieved with manual scoring, which was superior to automatic scoring. Manual scoring was also better than automatic scoring when OSA was defined according to other threshold values (> or = 5, 15 and 20) for the AHI. The combination of MESAM IV manual scores could reduce the need for diagnostic polysomnography in three quarters of the patients clinically suspected of having obstructive sleep apnoea, substantially reducing costs associated with diagnostic procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
A leisurely look at the bootstrap, the jackknife, and cross-validation
Efron, B., & Gong, G. (1983) · The American Statistician · doi:10.1080/00031305.1983.10483087 · Cited by 3,229 · cited 1×
“To address these two issues, the bootstrap method [22, 23] was used to estimate the standard error of the optimal cut-off point, and the bias and standard error of the corresponding validity indices (for more details see the Appendix).”
MethodEngleman, H. M., Martin, S. E., Douglas, N. J., & Deary, I. J. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91522-9 · Cited by 592
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
DURÁN, J., ESNAOLA, S., RUBIO, R., & IZTUETA, Á. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2005065 · Cited by 1,407
“The MESAM IV (Medizintechnik für Artz und Patient, Munich, Germany) is a four-channel digital recording system that has been previously validated (17, 18).”
MethodSelf-citationSleep Apnea as an Independent Risk Factor for All-Cause Mortality: The Busselton Health Study
(2008) · Sleep · doi:10.5665/sleep/31.8.1079 · Cited by 889
Martin, J. L., & Hakim, A. D. (2011) · Chest · doi:10.1378/chest.10-1872 · Cited by 603
Home Diagnosis of Sleep Apnea: A Systematic Review of the Literature
Flemons, W. W., Littner, M. R., Rowley, J. A., Gay, P., Anderson, W. M., Hudgel, D. W., McEvoy, R. D., & Loube, D. I. (2003) · Chest · doi:10.1378/chest.124.4.1543 · Cited by 571
Marshall, N. S., Wong, K. K. H., Cullen, S. R. J., Knuiman, M. W., & Grunstein, R. R. (2014) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.3600 · Cited by 513
“18,29,30 Underpowering is probably the biggest limitation to the Busselton Sleep Cohort, particularly with only 18 people in the highest exposure category.”
Evaluation of a Portable Device Based on Peripheral Arterial Tone for Unattended Home Sleep Studiesa
Bar, A., Pillar, G., Dvir, I., Sheffy, J., Schnall, R. P., & Lavie, P. (2003) · Chest · doi:10.1378/chest.123.3.695 · Cited by 219
Castronovo, V., Zucconi, M., Nosetti, L., Marazzini, C., Hensley, M., Veglia, F., Nespoli, L., & Ferini-Strambi, L. (2003) · The Journal of Pediatrics · doi:10.1067/mpd.2003.118 · Cited by 204
Marshall, N. S., Wong, K. K. H., Phillips, C. L., Liu, P. Y., Knuiman, M. W., & Grunstein, R. R. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27387 · Cited by 201
Home sleep studies in the assessment of sleep apnea/hypopnea syndrome
Golpe, R., Jime´nez, A., & Carpizo, R. (2002) · Chest · doi:10.1378/chest.122.4.1156 · Cited by 109
Long‐Term Results of Uvulopalatopharyngoplasty for Obstructive Sleep Apnea Syndrome
Boot, H., van Wegen, R., Poublon, R. M. L., Bogaard, J. M., Schmitz, P. I. M., & van der Meché, F. G. A. (2000) · The Laryngoscope · doi:10.1097/00005537-200003000-00027 · Cited by 95
Oliveira, M. G., Nery, L. E., Santos-Silva, R., Sartori, D. E., Alonso, F. F., Togeiro, S. M., Tufik, S., & Bittencourt, L. (2012) · Sleep Medicine · doi:10.1016/j.sleep.2012.06.011 · Cited by 45
“tive for OSAS diagnosis in patients with high clinical susceptibility [8–11].”
BackgroundPatel, M. R., Alexander, T. H., & Davidson, T. M. (2007) · Operative Techniques in Otolaryngology-Head and Neck Surgery · doi:10.1016/j.otot.2007.01.005 · Cited by 8
Metadata
- Authors
- Esnaola, S., Duran, J., Infante-Rivard, C., Rubio, R., & Fernandez, A.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1996-12-01
- Volume
- 9
- Issue
- 12
- Pages
- 2597-2605
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2161392521
- Cited by
- 110
- References
- 4
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.