CoChat

Effect of short- and long-acting inhaled beta2-agonists on exhaled nitric oxide in asthmatic patients

Open access
Yates, DH, Kharitonov, SA, Barnes, PJ · 1997 · European Respiratory Journal
Cited by 94

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Increased concentrations of exhaled nitric oxide (NO) occur in patients with asthma, and exhaled NO may be useful for assessing the effect of drug therapy on airway inflammation. Beta2-agonists have been proposed to have both proinflammatory and anti-inflammatory effects. We therefore assessed exhaled NO after beta2-agonists in asthmatic patients. Two randomized, double-blind, placebo-controlled studies were conducted. Firstly, exhaled NO was measured in 18 asthmatics (9 taking inhaled glucocorticosteroids (GCS)) before and after nebulized salbutamol (5 mg), or identical placebo (0.9% saline). Exhaled NO and forced expiratory volume in one second (FEV1) were measured at 15 min intervals for 1 h (Study 1). Secondly, the effect of 1 week of treatment with the long-acting beta2-agonist, salmeterol (50 microg b.i.d.), added to either budesonide (800 microg b.i.d.) or placebo, was studied in eight mild asthmatic subjects (Study 2). Exhaled NO was measured by a chemiluminescence analyser, adapted for on-line recording. In Study 1, exhaled NO showed no significant change at any time-point in patients not taking inhaled GCS. In asthmatics on inhaled GCS, exhaled NO increased compared to placebo at 15 and 30 min, but this did not reach statistical significance. In Study 2, treatment with salmeterol increased FEV1, but exhaled NO levels were not significantly changed, either after budesonide treatment (143+/-35 to 179+/-67 ppb), or after placebo (201+/-68 to 211+/-65 ppb). Our results confirm that single high dose salbutamol does not increase exhaled nitric oxide in asthmatics not taking inhaled glucocorticosteroids. Salbutamol may increase exhaled nitric oxide in asthmatics taking inhaled glucocorticosteroids. However, regular use of salmeterol resulted in no change in exhaled nitric oxide, either used alone or in combination with inhaled glucocorticosteroids.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.97.10071483

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 94

Metadata

Authors
Yates, D., Kharitonov, S., & Barnes, P.
Venue
European Respiratory Journal
Published
1997-07-01
Volume
10
Issue
7
Pages
1483-1488
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2108452934
Cited by
94
References
1
FWCI
5.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of short- and long-acting inhaled beta2-agonists on exhaled nitric oxide in asthmatic patients. https://app.cochat.ai/papers/10.1183/09031936.97.10071483
The paper
Yates, D., Kharitonov, S., & Barnes, P. (1997). Effect of short- and long-acting inhaled beta2-agonists on exhaled nitric oxide in asthmatic patients. European Respiratory Journal. https://doi.org/10.1183/09031936.97.10071483

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.