Evaluation of a movement detector to measure daily activity in patients with chronic lung disease
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
This study was designed to evaluate the performance of movement detectors (pedometers) in measuring daily activity of patients with chronic lung disease. Three groups of subjects were studied: group 1: 25 patients with stable nonhypercapnic chronic obstructive pulmonary disease (COPD) (forced expiratory volume in one second (FEV1) = 47+/-9% predicted) studied twice, one month apart; group 2: 25 patients with chronic respiratory failure studied before and three months after nasal nocturnal mechanical ventilation; and group 3: 25 normal healthy subjects studied once. The median level of activity in the healthy subjects (group 3) was three times greater than in either group of patients (groups 1 and 2). Activity levels were not correlated with age, sex or employment status. The repeatability of the activity counts in the nonhypercapnic COPD patients was high (intraclass correlation coefficient=0.94) and in these patients activity correlated significantly with FEV1 (r=0.54, p=0.006). In the respiratory failure patients, daytime arterial carbon dioxide pressure (Pa,CO2) improved following nasal nocturnal mechanical ventilation (NMV) (pre NMV: 8.5+/-1.2 kPa; post NMV: 6.2+/-0.5 kPa), health status improved (p<0.004) and daily movement count doubled (p<0.0001). This increase correlated with change in Pa,CO2 (r-0.53, p=0.006), but not with improved health status. We conclude that motion detectors may provide repeatable measures of daily activity that are related to physiological impairment and improvement following treatment. Activity counts appear to be complementary to estimates of exercise limitation obtained using health questionnaires.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, P. W., Quirk, F. H., Baveystock, C. M., & Littlejohns, P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.6.1321 · Cited by 3,035
Self-citationThe St George's Respiratory Questionnaire
Jones, P. W., Quirk, F. H., & Baveystock, C. M. (1991) · Respiratory Medicine · doi:10.1016/s0954-6111(06)80166-6 · Cited by 2,683 · cited 6×
“There were significant improvements in the SGRQ scores (indicated by a fall in score) post-NMV: Activity score: pre 78 (±13), post 65 (±22) (p= 0.004); Impacts: pre 52 (±19), post 40 (±23) (p=0.013); Total: pre 60 (±13), post 49 (±19) (p=0.004).”
BackgroundMethodSelf-citationMaximal respiratory pressures: normal values and relationship to age and sex.
Black, L. F., & Hyatt, R. E. (1969) · PubMed · doi:10.1164/arrd.1969.99.5.696 · Cited by 1,877
A measure of quality of life for clinical trials in chronic lung disease
Guyatt, G. H., Berman, L. B., Townsend, M., Pugsley, S. O., & Chambers, L. W. (1987) · Thorax · doi:10.1136/thx.42.10.773 · Cited by 1,721 · cited 1×
“Self-reported exercise impairment measured by dyspnoea scales [2] or health status questionnaires [4, 5] assess physical limitation by identifying those activities that are either not possible or are difficult to perform because of breathlessness or fatigue.”
BackgroundMahler, D. A., Weinberg, D. H., Wells, C. K., & Feinstein, A. R. (1984) · Chest · doi:10.1378/chest.85.6.751 · Cited by 1,292
Twelve-minute walking test for assessing disability in chronic bronchitis.
McGavin, C. R., Gupta, S. P., & McHardy, G. J. (1976) · BMJ · doi:10.1136/bmj.1.6013.822 · Cited by 742
Meecham Jones, D. J., Paul, E. A., Jones, P. W., & Wedzicha, J. A. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633704 · Cited by 479 · cited 1×
“Health status also improved significantly, confirming recent findings in patients with COPD receiving nocturnal pressure support [15].”
BackgroundSelf-citationMcGavin, C. R., Artvinli, M., Naoe, H., & McHardy, G. J. (1978) · BMJ · doi:10.1136/bmj.2.6132.241 · Cited by 434
How should we measure function in patients with chronic heart and lung disease?
Guyatt, G. H., Thompson, P. J., Berman, L. B., Sullivan, M. J., Townsend, M., Jones, N. L., & Pugsley, S. O. (1985) · Journal of Chronic Diseases · doi:10.1016/0021-9681(85)90035-9 · Cited by 432
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
MELANSON, E. L., & FREEDSON, P. S. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199506000-00021 · Cited by 416 · cited 1×
“Sophisticated computerized actigraphs and accelerometers are now available for assessing temporal and spatial movement parameters [18, 19], but, they are expensive.”
BackgroundAccelerometry—A technique for the measurement of human body movements
Morris, J. R. W. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90029-8 · Cited by 325 · cited 1×
“Sophisticated computerized actigraphs and accelerometers are now available for assessing temporal and spatial movement parameters [18, 19], but, they are expensive.”
BackgroundSwinburn, C. R., Wakefield, J. M., & Jones, P. W. (1985) · Thorax · doi:10.1136/thx.40.8.581 · Cited by 180
Self-citationRespiratory Muscle Rest Using Nasal BiPAP Ventilation in Patients With Stable Severe COPD
Renston, J. P., DiMarco, A. F., & Supinski, G. S. (1994) · CHEST Journal · doi:10.1378/chest.105.4.1053 · Cited by 132
Predicting Maximal Exercise Ventilation in Patients with Chronic Obstructive Pulmonary Disease
Carter, R., Peavler, M., Zinkgraf, S. A., Williams, J. V., & Fields, S. (1987) · CHEST Journal · doi:10.1378/chest.92.2.253 · Cited by 79 · cited 1×
“The level of correlation was generally better than that reported between walking distance and FEV1 [2, 10– 12] and comparable to correlations between peak cycleergometer performance and spirometry [13, 14].”
ResultO'Reilly, J. F., Shaylor, J. M., Fromings, K. M., & Harrison, B. D. (1982) · British Journal of Diseases of the Chest · doi:10.1016/0007-0971(82)90073-0 · Cited by 47
Matthews, J. L., Bush, B. A., & Ewald, F. W. (1989) · CHEST Journal · doi:10.1378/chest.96.1.11 · Cited by 46 · cited 1×
“The level of correlation was generally better than that reported between walking distance and FEV1 [2, 10– 12] and comparable to correlations between peak cycleergometer performance and spirometry [13, 14].”
Result
Cited by
Characteristics of physical activities in daily life in chronic obstructive pulmonary disease
Pitta, F., Troosters, T., Spruit, M. A., Probst, V. S., Decramer, M., & Gosselink, R. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200407-855oc · Cited by 1,256
“By using “activity counts” as outcome, Schonhofer and coworkers (9) and Singh and Morgan (28) described that patients with COPD had levels of daily movement counts that were lower than the average level recorded in age- and sex-matched healthy subjects.”
BackgroundMethodBrunelli, A., Charloux, A., Bolliger, C. T., Rocco, G., Sculier, J.-P., Varela, G., Licker, M., Ferguson, M. K., Faivre-Finn, C., Huber, R. M., et al. (2009) · European Respiratory Journal · doi:10.1183/09031936.00184308 · Cited by 955
Physical activity in patients with COPD
Watz, H., Waschki, B., Meyer, T., & Magnussen, H. (2009) · European Respiratory Journal · doi:10.1183/09031936.00024608 · Cited by 684
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Pulmonary Rehabilitation in Chronic Obstructive Pulmonary Disease
Troosters, T., Casaburi, R., Gosselink, R., & Decramer, M. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200408-1109so · Cited by 649
Metadata
- Authors
- Schonhofer, B., Ardes, P., Geibel, M., Kohler, D., & Jones, P.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1997-12-01
- Volume
- 10
- Issue
- 12
- Pages
- 2814-2819
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2105871356
- Cited by
- 181
- References
- 16
- FWCI
- 0.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.