The DOI matches its Crossref record.
Validity of the Computer Science and Applications, Inc. (CCA) activity monitor
Abstract
The validity of the Computer Science and Applications, Inc. (CSA) accelerometer in assessing physical activity was assessed during treadmill walking and running at three different grades. Energy expenditure (EE) served as the criterion measure. CSA data were compared to data collected with the Caltrac accelerometer. Both accelerometers were sensitive to changes in treadmill speed, but neither discriminated changes in treadmill grade. Caltrac and CSA activity counts were significantly and similarly correlated with EE (r = 0.66-0.82), relative VO2 (r = 0.77-0.89), heart rate (r = 0.66-0.80), treadmill speed (r = 0.82-0.92), and with each other (r = 0.77-0.82). CSA data were used to develop models to predict EE (kcal.min-1). Cross-validation resulted in a mean difference between actual and predicted EE of 0.02 kcal.min-1 (SEE = 0.85 kcal.min-1). The range of individual differences in the validation group was large for both the CSA model (-2.86 to +3.86 kcal.min-1) and Caltrac (-4.17 to +2.04 kcal.min-1). It is concluded that the CSA and Caltrac accelerometers have similar validity and that either instrument can be used to estimate EE of groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Self-citationConducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Neighborhood-based differences in physical activity: an environment scale evaluation
Saelens, B. E., Sallis, J. F., Black, J. B., & Chen, D. (2003) · American Journal of Public Health · doi:10.2105/ajph.93.9.1552 · Cited by 1,954
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Metadata
- Authors
- MELANSON, E. L., & FREEDSON, P. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1995-06
- Volume
- 27
- Issue
- 6
- Pages
- 934???940
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2020440525
- Cited by
- 416
- References
- 0
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of the Computer Science and Applications, Inc. (CCA) activity monitor. https://app.cochat.ai/papers/10.1249/00005768-199506000-00021
- The paper
- MELANSON, E. L., & FREEDSON, P. S. (1995). Validity of the Computer Science and Applications, Inc. (CCA) activity monitor. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199506000-00021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.