CoChat

Incremental threshold loading: a standard protocol and establishment of a reference range in naive normal subjects

Open access
Johnson, PH, Cowley, AJ, Kinnear, WJ · 1997 · European Respiratory Journal
Cited by 41

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Incremental threshold loading (ITL) has been proposed as a test of inspiratory muscle strength and endurance. To date, however, there has been no standardized protocol for an ITL test, and no reference range, with different investigators using a variety of different pressure increments in small numbers of subjects. We developed an ITL test using the weighted plunger (WP) principle, which uses standard increments of pressure. In our protocol subjects inspire through the WP generating an initial threshold opening pressure of 10 cmH2O. This pressure is raised at 2 min intervals in increments of 5 cmH2O until they fail to lift the plunger on two consecutive attempted breaths. Sixty healthy volunteers (30 males and 30 females) aged 20-80 yrs performed the ITL test. Twelve subjects (six females and six males) performed the test twice to assess reproducibility and repeatability. Using stepwise multiple linear regression, we regressed the maximum threshold pressure sustained for a full 2 min (Pmax) against age, height, weight and static maximum inspiratory mouth pressure (MIP). Pmax was significantly related to age but not to either height or weight, the regression equation for males was Pmax (cmH2O)=103.8 - (1.0 x age in years), and for females was Pmax (cmH2O)=93.7 - (1.0 x age in years). The within-subject standard deviation for those repeating the ITL test was 5.4 cmH2O. Incremental threshold loading is a simple technique with good reproducibility, which most naive subjects can use without difficulty. By using standard pressure increments and performing the test in a large number of naive subjects, we have established a reference range that should be applicable wherever similar pressure increments are used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.97.10122868

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 41

Metadata

Authors
Johnson, P., Cowley, A., & Kinnear, W.
Venue
European Respiratory Journal
Published
1997-12-01
Volume
10
Issue
12
Pages
2868-2871
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2119043947
Cited by
41
References
1
FWCI
5.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incremental threshold loading: a standard protocol and establishment of a reference range in naive normal subjects. https://app.cochat.ai/papers/10.1183/09031936.97.10122868
The paper
Johnson, P., Cowley, A., & Kinnear, W. (1997). Incremental threshold loading: a standard protocol and establishment of a reference range in naive normal subjects. European Respiratory Journal. https://doi.org/10.1183/09031936.97.10122868

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.