CoChat

Changes in exhaled carbon monoxide and nitric oxide levels following allergen challenge in patients with asthma

Open access
Paredi, P, Leckie, MJ, Horvath, I, Allegra, L, Kharitonov, SA, Barnes, PJ · 1999 · European Respiratory Journal
Cited by 104

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Carbon monoxide is a product of haem degradation by haem oxygenase (HO), activated by inflammatory cytokines and oxidants. This study examined whether allergen challenge can increase exhaled CO levels, as a reflection of HO activation. Exhaled CO and nitric oxide, an expired gas also thought to reflect cytokine-induced airway inflammation, were measured in 15 atopic steroid-naive nonsmoking patients with asthma (13 males, aged 30+/-2 yrs) before and for up to 20 h after allergen challenge. Baseline CO (4.4+/-0.3 parts per million (ppm)) and NO (20.6+/-1.2 parts per billion (ppb)) levels were elevated in asthmatic as compared with nonsmoking normal volunteers (n = 37, 2.1+/-0.2 ppm and 7.0+/-0.1 ppb, respectively, p<0.05). In 10 patients with a dual response in the forced expiratory volume in one second (FEV1) there was a maximal increase in exhaled CO at 1 h (343+/-7.1%) and at 6 h (69+/-12%, p<0.01), followed by a maximal fall in FEV1 (28+/-9%, p<0.05) at 9 h, whereas the maximal NO increase was observed at 10 h (50.2+/-11.8%). The maximal increase in exhaled CO in single response patients (n = 5) was 30+/-2% during the early asthmatic reaction and 46.3+/-9.2% between 4 and 10 h, followed by a fall in FEV1 (9+/-3%, p>0.05) at 9 h, whereas exhaled NO was not significantly changed. In five patients exhaled CO was not attenuated by inhalation of increasing concentrations of histamine causing a 20% fall in FEV1 (PC20) or its subsequent relief by beta2-agonists. In conclusion, exhaled carbon monoxide is increased during the early and late asthmatic reactions independently of the change in airway calibre, while exhaled nitric oxide is increased only during the late reaction and follows the increase in carbon monoxide and fall in the forced expiratory volume in one second in time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/09031936.99.13104899

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 104

Metadata

Authors
Paredi, P., Leckie, M., Horvath, I., Allegra, L., Kharitonov, S., & Barnes, P.
Venue
European Respiratory Journal
Published
1999-01-01
Volume
13
Issue
1
Pages
48-52
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2168706601
Cited by
104
References
3
FWCI
4.67
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.