Effect of mouth leak on effectiveness of nasal bilevel ventilatory assistance and sleep architecture
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Mouth leak is common during nasal ventilatory assistance, but its effects on ventilatory support and on sleep architecture are unknown. The acute effect of sealing the mouth on sleep architecture and transcutaneous carbon dioxide tension (Ptc,CO2) was tested in 9 patients (7 hypercapnic) on longterm nasal bilevel ventilation with symptomatic mouth leak. Patients slept with nasal bilevel ventilation at their usual settings on two nights in random order. On one night, the mouth was taped closed. Leak was measured with a pneumotachograph. Median leak fell from 0.35+/-0.07 (mean +/- SEM) L x s(-1) untaped to 0.06+/-0.03 L x s(-1) taped. Ptc,CO2 fell in 8/9, including all hypercapnic patients. Across all patients, the mean Ptc,CO2 fell by 1.02+/-0.28 kPa (7.7+/-2.1 mm Hg) with taping (p = 0.007). Arousal index fell in every patient. Mean arousal index fell from 35.0+/-3.0 to 13.9+/-1.2 h(-1) (p<0.0001), and rapid eye movement (REM) sleep increased from 12.9+/-1.5% to 21.1+/-1.8% sleep time (p = 0.0016). Slow wave sleep changed inconsistently, from a mean of 13.1+/-1.6% to 19.5+/-2.2% of sleep (p = 0.09). Sleep latency and efficiency were unchanged. In four healthy volunteers ventilator-induced awake hypopharyngeal pressure swing during timed bilevel ventilation fell by 35+/-5% L(-1) x s(-1) of voluntary mouth leak (p<0.0001). Mouth leak reduces effective nasal bilevel ventilatory support, increases transcutaneous carbon dioxide tension, and disrupts sleep architecture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Side Effects of Nasal Continuous Positive Airway Pressure in Sleep Apnea Syndrome
Pépin, J. L., Leger, P., Veale, D., Langevin, B., Robert, D., & Lévy, P. (1995) · Chest · doi:10.1378/chest.107.2.375 · Cited by 422
Hoffstein, V., Viner, S., Mateika, S., & Conway, J. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.4_pt_1.841 · Cited by 317
Ventilatory Muscle Support in Respiratory Failure with Nasal Positive Pressure Ventilation
Carrey, Z., Gottfried, S. B., & Levy, R. D. (1990) · CHEST Journal · doi:10.1378/chest.97.1.150 · Cited by 316 · cited 1×
“In the only study to date to directly measure the effect of mouth leaks on effectiveness of ventilatory support, CAR-REY et al. [ 6 ] investigated the effect of voluntary mouth opening on diaphragm electromyogram (EMG) activity during awake nasal intermittent positive pressure ventilation in 5 subjects.”
BackgroundMouth leak with nasal continuous positive airway pressure increases nasal airway resistance.
Richards, G. N., Cistulli, P. A., Ungar, R. G., Berthon-Jones, M., & Sullivan, C. E. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.1.8680678 · Cited by 281
Self-citationEllis, E. R., Bye, P. T. P., Bruderer, J. W., & Sullivan, C. E. (1987) · PubMed · doi:10.1164/arrd.1987.135.1.148 · Cited by 261
Bach, J. R., Alba, A., Mosher, R., & Delaubier, A. (1987) · Chest · doi:10.1378/chest.92.1.168 · Cited by 175
Air Leaking Through the Mouth During Nocturnal Nasal Ventilation: Effect on Sleep Quality
Meyer, T. J., Pressman, M. R., Benditt, J., McCool, F. D., Millman, R. P., Natarajan, R., & Hill, N. S. (1997) · Sleep · doi:10.1093/sleep/20.7.561 · Cited by 131
Physiologic Evaluation of Pressure Support Ventilation by Nasal Mask in Patients with Stable COPD
Ambrosino, N., Nava, S., Bertone, P., Fracchia, C., & Rampulla, C. (1992) · CHEST Journal · doi:10.1378/chest.101.2.385 · Cited by 130
Hayes, M. J., McGregor, F. B., Roberts, D. N., Schroter, R. C., & Pride, N. B. (1995) · Thorax · doi:10.1136/thx.50.11.1179 · Cited by 83 · cited 1×
“volunteers. HAYES et al. [ 10 ] showed that mouth leak 100”
BackgroundElliott, M. W., & Simonds, A. K. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08030436 · Cited by 41 · cited 1×
“The second possible mechanism for the observed 1.02 kPa (7.7 mmHg) decrease in Ptc,CO2 without taping is due to worse gas exchange due to loss of expiratory pressure, as shown for patients with neuromuscular/skeletal disorders by ELLIOTT and SIMMONDS [ 11 ].”
BackgroundInfluential
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Non-invasive ventilation in acute respiratory failure
(2002) · Thorax · doi:10.1136/thorax.57.3.192 · Cited by 652
NPPV Titration Task Force of the American Academy of Sleep Medicine, Berry, R. B., Chediak, A., Brown, L. K., Finder, J., Gozal, D., Iber, C., Kushida, C. A., Morgenthaler, T., Rowley, J. A., et al. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27941 · Cited by 315
Janssens, J.-P., Borel, J.-C., Pepin, J.-L., & on behalf of the SomnoNIV Group (2011) · Thorax · doi:10.1136/thx.2010.139782 · Cited by 251
Fanfulla, F., Delmastro, M., Berardinelli, A., Lupo, N. D., & Nava, S. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-694oc · Cited by 184
“Factors that could contribute to onset of ineffective efforts may differ from patient to patient: reduction in respiratory drive, reduction in respiratory muscle strength, increased inspiratory load due to augmented upper airway resistance, and mouth leaks may all contribute to the inability to trigger the ventilator…”
Background
Metadata
- Authors
- Teschler, H., Stampa, J., Ragette, R., Konietzko, N., & Berthon-Jones, M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 1999-12-01
- Volume
- 14
- Issue
- 6
- Pages
- 1251-1257
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2125661811
- Cited by
- 196
- References
- 10
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.