Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 250

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Baseline patient factors impact on the clinical efficacy of benralizumab for severe asthma

Open access
Bleecker, Eugene R., Wechsler, Michael E., FitzGerald, J. Mark, Menzies-Gow, Andrew, Wu, Yanping, Hirsch, Ian, Goldman, Mitchell, Newbold, Paul, Zangrilli, James G. · 2018 · European Respiratory Journal

Abstract

Benralizumab is an anti-eosinophilic monoclonal antibody that reduces exacerbations and improves lung function for patients with severe, uncontrolled asthma with eosinophilic inflammation. We evaluated the impact of baseline factors on benralizumab efficacy for patients with severe asthma. This analysis used pooled data from the SIROCCO (ClinicalTrials.gov identifier NCT01928771) and CALIMA (ClinicalTrials.gov identifier NCT01914757) Phase III studies. Patients aged 12–75 years with severe, uncontrolled asthma receiving high-dosage inhaled corticosteroids plus long-acting β 2-agonists received benralizumab 30 mg subcutaneously every 8 weeks (Q8W, first three doses every 4 weeks (Q4W)), Q4W or placebo. Baseline factors that influenced benralizumab efficacy were evaluated, including oral corticosteroid (OCS) use, nasal polyposis, pre-bronchodilator forced vital capacity (FVC), prior year exacerbations and age at diagnosis. Efficacy outcomes included annual exacerbation rate and change in pre-bronchodilator forced expiratory volume in 1 s at treatment end relative to placebo. Benralizumab Q8W treatment effect was enhanced with each baseline factor for all patients and those with ≥300 eosinophils·μL−1 relative to the overall population. OCS use, nasal polyposis and FVC <65% of predicted were associated with greater benralizumab Q8W responsiveness for reduced exacerbation rate for patients with <300 eosinophils·μL−1. Baseline clinical factors and blood eosinophil counts can help identify patients potentially responsive to benralizumab.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1183/13993003.00936-2018

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Bleecker, E. R., Wechsler, M. E., FitzGerald, J. M., Menzies-Gow, A., Wu, Y., Hirsch, I., Goldman, M., Newbold, P., & Zangrilli, J. G.
Venue
European Respiratory Journal
Published
2018-08-23
Volume
52
Issue
4
Pages
1800936
ISSN
  • 0903-1936 (ISSN-L)
  • 1399-3003
OpenAlex
W2888063502
Cited by
250
References
2
FWCI
16.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.