MALDI imaging mass spectrometry: statistical data analysis and current computational challenges
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) imaging mass spectrometry, also called MALDI-imaging, is a label-free bioanalytical technique used for spatially-resolved chemical analysis of a sample. Usually, MALDI-imaging is exploited for analysis of a specially prepared tissue section thaw mounted onto glass slide. A tremendous development of the MALDI-imaging technique has been observed during the last decade. Currently, it is one of the most promising innovative measurement techniques in biochemistry and a powerful and versatile tool for spatially-resolved chemical analysis of diverse sample types ranging from biological and plant tissues to bio and polymer thin films. In this paper, we outline computational methods for analyzing MALDI-imaging data with the emphasis on multivariate statistical methods, discuss their pros and cons, and give recommendations on their application. The methods of unsupervised data mining as well as supervised classification methods for biomarker discovery are elucidated. We also present a high-throughput computational pipeline for interpretation of MALDI-imaging data using spatial segmentation. Finally, we discuss current challenges associated with the statistical analysis of MALDI-imaging data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The class imbalance problem: A systematic study1
Japkowicz, N., & Stephen, S. (2002) · Intelligent Data Analysis · doi:10.3233/ida-2002-6504 · Cited by 3,295 · cited 2×
“However, for compensating a strong imbalance, advanced methods (e.g. sampling and cost-sensitive learning) are recommended, see [49-51].”
BackgroundMethodMolecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234 · cited 2×
“Matrix-assisted laser desorption/ionization-time of-flight imaging mass spectrometry, also called MALDI-imaging, emerged in the late 1990s [1,17] and has opened new horizons for application of mass spectrometry in biology and medicine [18].”
BackgroundAnalytical and bioanalytical chemistry
de chimie, S. F. (2002) · Springer eBooks · Cited by 1,256
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172 · cited 1×
“Matrix-assisted laser desorption/ionization-time of-flight imaging mass spectrometry, also called MALDI-imaging, emerged in the late 1990s [1,17] and has opened new horizons for application of mass spectrometry in biology and medicine [18].”
BackgroundIdentifying Mislabeled Training Data
Brodley, C. E., & Friedl, M. A. (1999) · Cited by 718
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652 · cited 1×
“Moreover, see recent surveys [2,22,23] for a mass spectrometric perspective and [3] for a microbiology perspective.”
BackgroundWiseman, J. M., Ifa, D. R., Song, Q., & Cooks, R. G. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200602449 · Cited by 626 · cited 1×
“Other emerging IMS techniques such as desorption electrospray ionization (DESI) [14], laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) [15], or nanos-tructure-initiator mass spectrometry (NIMS) [16], are not considered either.”
MethodIdentifying Mislabeled Training Data
Brodley, C. E., & Friedl, M. A. (1999) · Journal of Artificial Intelligence Research · doi:10.1613/jair.606 · Cited by 612 · cited 1×
“In statistical learning, this effect is referred to as classification noise or noise in labels [55].”
BackgroundClathrate nanostructures for mass spectrometry
Northen, T. R., Yanes, O., Northen, M. T., Marrinucci, D., Uritboonthai, W., Apon, J., Golledge, S. L., Nordström, A., & Siuzdak, G. (2007) · Nature · doi:10.1038/nature06195 · Cited by 480 · cited 1×
“Other emerging IMS techniques such as desorption electrospray ionization (DESI) [14], laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) [15], or nanos-tructure-initiator mass spectrometry (NIMS) [16], are not considered either.”
MethodA concise review of mass spectrometry imaging
Amstalden van Hove, E. R., Smith, D. F., & Heeren, R. M. A. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.01.033 · Cited by 416
Cited by
Mass Spectrometry Imaging: A Review of Emerging Advancements and Future Insights
Buchberger, A. R., DeLaney, K., Johnson, J., & Li, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04733 · Cited by 1,029
Guo, L., Panderi, I., Yan, D. D., Szulak, K., Li, Y., Chen, Y.-T., Ma, H., Niesen, D. B., Seeram, N., Ahmed, A., et al. (2013) · ACS Nano · doi:10.1021/nn403202w · Cited by 316
–Omic and Electronic Health Record Big Data Analytics for Precision Medicine
Wu, P.-Y., Cheng, C.-W., Kaddi, C. D., Venugopalan, J., Hoffman, R., & Wang, M. D. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2573285 · Cited by 303
Mass spectrometry imaging for plant biology: a review
Boughton, B. A., Thinagaran, D., Sarabia, D., Bacic, A., & Roessner, U. (2016) · Phytochemistry Reviews · doi:10.1007/s11101-015-9440-2 · Cited by 300
Spatial Metabolomics and Imaging Mass Spectrometry in the Age of Artificial Intelligence
Alexandrov, T. (2020) · Annual Review of Biomedical Data Science · doi:10.1146/annurev-biodatasci-011420-031537 · Cited by 284
Self-citationMALDI imaging mass spectrometry: Spatial molecular analysis to enable a new age of discovery
Gessel, M. M., Norris, J. L., & Caprioli, R. M. (2014) · Journal of Proteomics · doi:10.1016/j.jprot.2014.03.021 · Cited by 276
Ly, A., Buck, A., Balluff, B., Sun, N., Gorzolka, K., Feuchtinger, A., Janssen, K.-P., Kuppen, P. J. K., van de Velde, C. J. H., Weirich, G., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.081 · Cited by 243
Molecular assessment of surgical-resection margins of gastric cancer by mass-spectrometric imaging
Eberlin, L. S., Tibshirani, R. J., Zhang, J., Longacre, T. A., Berry, G. J., Bingham, D. B., Norton, J. A., Zare, R. N., & Poultsides, G. A. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1400274111 · Cited by 225
Guenther, S., Muirhead, L. J., Speller, A. V. M., Golf, O., Strittmatter, N., Ramakrishnan, R., Goldin, R. D., Jones, E., Veselkov, K., Nicholson, J., et al. (2015) · Cancer Research · doi:10.1158/0008-5472.can-14-2258 · Cited by 159
“Recursive maximum margin criterion (RMMC) analysis was used for supervised discrimination and classification (25, 26).”
MethodClinical protein science in translational medicine targeting malignant melanoma
Gil, J., Betancourt, L. H., Pla, I., Sanchez, A., Appelqvist, R., Miliotis, T., Kuras, M., Oskolas, H., Kim, Y., Horvath, Z., et al. (2019) · Cell Biology and Toxicology · doi:10.1007/s10565-019-09468-6 · Cited by 45
“This effectively shifts some of the responsibility from the preprocessing step to later stages (Alexandrov 2012).”
Background
Metadata
- Authors
- Alexandrov, T.
- Venue
- BMC Bioinformatics
- Published
- 2012-11
- Volume
- 13
- Issue
- S16
- Pages
- S11-S11
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W1608430727
- Cited by
- 237
- References
- 48
- FWCI
- 6.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.