Precise protein quantification based on peptide quantification using iTRAQ™
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Mass spectrometry based quantification of peptides can be performed using the iTRAQ reagent in conjunction with mass spectrometry. This technology yields information about the relative abundance of single peptides. A method for the calculation of reliable quantification information is required in order to obtain biologically relevant data at the protein expression level. RESULTS: A method comprising sound error estimation and statistical methods is presented that allows precise abundance analysis plus error calculation at the peptide as well as at the protein level. This yields the relevant information that is required for quantitative proteomics. Comparing the performance of our method named Quant with existing approaches the error estimation is reliable and offers information for precise bioinformatic models. Quant is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems. Moreover, the results are consistent with that of Mascot 2.2. The MATLAB scripts of Quant are freely available via http://www.protein-ms.de and http://sourceforge.net/projects/protms/, each under the GNU Lesser General Public License. CONCLUSION: The software Quant demonstrates improvements in protein quantification using iTRAQ. Precise quantification data can be obtained at the protein level when using error propagation and adequate visualization. Quant integrates both and additionally provides the possibility to obtain more reliable results by calculation of wise quality measures. Peak area integration has been replaced by sum of intensities, yielding more reliable quantification results. Additionally, Quant allows the combination of quantitative information obtained by iTRAQ with peptide and protein identifications from popular tandem MS identification tools. Hence Quant is a useful tool for the proteomics community and may help improving analysis of proteomic experimental data. In addition, we have shown that a lognormal distribution fits the data of mass spectrometry based relative peptide quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Quantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 1×
“Differences in protein expression are not accessible at genomic level but often are accessible at the proteome level [6].”
BackgroundRoss, P. L., Huang, Y. N., Marchese, J. N., Williamson, B., Parker, K., Hattan, S., Khainovski, N., Pillai, S., Dey, S., Daniels, S., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400129-mcp200 · Cited by 4,401 · cited 3×
“The label is composed of a peptide reactive group (red, NHS ester) and an isobaric tag of 145 Da, which consists of a balancer group (blue, carbonyl group) and a reporter group (green, N-methylpiperazine).”
BackgroundInfluentialMass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572 · cited 2×
“A common method in error estimation is done by using the mean value μ, the standard deviation σ and by applying the kσ-rule and the Tschebyschew-equation and has been proposed for quantification [12].”
BackgroundMethod
Cited by
Addressing Accuracy and Precision Issues in iTRAQ Quantitation
Karp, N. A., Huber, W., Sadowski, P. G., Charles, P. D., Hester, S. V., & Lilley, K. S. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900628-mcp200 · Cited by 495
Cerebrospinal fluid chitinase 3-like 1 levels are associated with conversion to multiple sclerosis
Comabella, M., Fernández, M., Martin, R., Rivera-Vallvé, S., Borrás, E., Chiva, C., Julià, E., Rovira, A., Cantó, E., Alvarez-Cermeño, J. C., et al. (2010) · Brain · doi:10.1093/brain/awq035 · Cited by 300
An insight into iTRAQ: where do we stand now?
Evans, C., Noirel, J., Ow, S. Y., Salim, M., Pereira-Medrano, A. G., Couto, N., Pandhal, J., Smith, D., Pham, T. K., Karunakaran, E., et al. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-5918-6 · Cited by 300
Ion Coalescence of Neutron Encoded TMT 10-Plex Reporter Ions
Werner, T., Sweetman, G., Savitski, M. F., Mathieson, T., Bantscheff, M., & Savitski, M. M. (2014) · Analytical Chemistry · doi:10.1021/ac500140s · Cited by 258
Wang, H., Alvarez, S., & Hicks, L. M. (2012) · Journal of Proteome Research · doi:10.1021/pr2008225 · Cited by 142
Metadata
- Authors
- Boehm, A. M., Pütz, S., Altenhöfer, D., Sickmann, A., & Falk, M.
- Venue
- BMC Bioinformatics
- Published
- 2007-06-21
- Volume
- 8
- Issue
- 1
- Pages
- 214-214
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2073352191
- Cited by
- 110
- References
- 4
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precise protein quantification based on peptide quantification using iTRAQ™. https://app.cochat.ai/papers/10.1186/1471-2105-8-214
- The paper
- Boehm, A. M., Pütz, S., Altenhöfer, D., Sickmann, A., & Falk, M. (2007). Precise protein quantification based on peptide quantification using iTRAQ™. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-8-214
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.