CoChat

Precise protein quantification based on peptide quantification using iTRAQ™

Open access
Boehm, Andreas M, Pütz, Stephanie, Altenhöfer, Daniela, Sickmann, Albert, Falk, Michael · 2007 · BMC Bioinformatics
Cited by 110

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Mass spectrometry based quantification of peptides can be performed using the iTRAQ reagent in conjunction with mass spectrometry. This technology yields information about the relative abundance of single peptides. A method for the calculation of reliable quantification information is required in order to obtain biologically relevant data at the protein expression level. RESULTS: A method comprising sound error estimation and statistical methods is presented that allows precise abundance analysis plus error calculation at the peptide as well as at the protein level. This yields the relevant information that is required for quantitative proteomics. Comparing the performance of our method named Quant with existing approaches the error estimation is reliable and offers information for precise bioinformatic models. Quant is shown to generate results that are consistent with those produced by ProQuant, thus validating both systems. Moreover, the results are consistent with that of Mascot 2.2. The MATLAB scripts of Quant are freely available via http://www.protein-ms.de and http://sourceforge.net/projects/protms/, each under the GNU Lesser General Public License. CONCLUSION: The software Quant demonstrates improvements in protein quantification using iTRAQ. Precise quantification data can be obtained at the protein level when using error propagation and adequate visualization. Quant integrates both and additionally provides the possibility to obtain more reliable results by calculation of wise quality measures. Peak area integration has been replaced by sum of intensities, yielding more reliable quantification results. Additionally, Quant allows the combination of quantitative information obtained by iTRAQ with peptide and protein identifications from popular tandem MS identification tools. Hence Quant is a useful tool for the proteomics community and may help improving analysis of proteomic experimental data. In addition, we have shown that a lognormal distribution fits the data of mass spectrometry based relative peptide quantification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/1471-2105-8-214

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 110

Metadata

Authors
Boehm, A. M., Pütz, S., Altenhöfer, D., Sickmann, A., & Falk, M.
Venue
BMC Bioinformatics
Published
2007-06-21
Volume
8
Issue
1
Pages
214-214
ISSN
1471-2105 (ISSN-L)
OpenAlex
W2073352191
Cited by
110
References
4
FWCI
4.79
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Precise protein quantification based on peptide quantification using iTRAQ™. https://app.cochat.ai/papers/10.1186/1471-2105-8-214
The paper
Boehm, A. M., Pütz, S., Altenhöfer, D., Sickmann, A., & Falk, M. (2007). Precise protein quantification based on peptide quantification using iTRAQ™. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-8-214

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.