The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly sensitive feature detection for high resolution LC/MS
Open accessAbstract
BACKGROUND: Liquid chromatography coupled to mass spectrometry (LC/MS) is an important analytical technology for e.g. metabolomics experiments. Determining the boundaries, centres and intensities of the two-dimensional signals in the LC/MS raw data is called feature detection. For the subsequent analysis of complex samples such as plant extracts, which may contain hundreds of compounds, corresponding to thousands of features -- a reliable feature detection is mandatory. RESULTS: We developed a new feature detection algorithm centWave for high-resolution LC/MS data sets, which collects regions of interest (partial mass traces) in the raw-data, and applies continuous wavelet transformation and optionally Gauss-fitting in the chromatographic domain. We evaluated our feature detection algorithm on dilution series and mixtures of seed and leaf extracts, and estimated recall, precision and F-score of seed and leaf specific features in two experiments of different complexity. CONCLUSION: The new feature detection algorithm meets the requirements of current metabolomics experiments. centWave can detect close-by and partially overlapping features and has the highest overall recall and precision values compared to the other algorithms, matchedFilter (the original algorithm of XCMS) and the centroidPicker from MZmine. The centWave algorithm was integrated into the Bioconductor R-package XCMS and is available from (http://www.bioconductor.org/).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Data processing for mass spectrometry-based metabolomics
Katajamaa, M., & Orešič, M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.021 · Cited by 616 · cited 2×
“3 Parameter optimisation Beside centWave, there are currently only two other feature detection algorithms available [9], which meet the following criteria: freely available, open source, and suited for feature detection in metabolomic LC/MS samples measured in centroid mode: matchedFilter- the originally implemented a…”
BackgroundMethod
Cited by
Lommen, A. (2009) · Analytical Chemistry · doi:10.1021/ac900036d · Cited by 734
Serine is a natural ligand and allosteric activator of pyruvate kinase M2
Chaneton, B., Hillmann, P., Zheng, L., Martin, A. C. L., Maddocks, O. D. K., Chokkathukalam, A., Coyle, J. E., Jankevics, A., Holding, F. P., Vousden, K. H., et al. (2012) · Nature · doi:10.1038/nature11540 · Cited by 661
Fecal microbiota transplantation plus anti-PD-1 immunotherapy in advanced melanoma: a phase I trial
Routy, B., Lenehan, J. G., Miller, W. H., Jamal, R., Messaoudene, M., Daisley, B. A., Hes, C., Al, K. F., Martinez-Gili, L., Punčochář, M., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02453-x · Cited by 526
Gorrochategui, E., Jaumot, J., Lacorte, S., & Tauler, R. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.07.004 · Cited by 352
bioinformatics tools for mass spectroscopy-based metabolomic data processing and analysis
Sugimoto, M., Kawakami, M., Robert, M., Soga, T., & Tomita, M. (2012) · Current Bioinformatics · doi:10.2174/157489312799304431 · Cited by 307
Metadata
- Authors
- Tautenhahn, R., Böttcher, C., & Neumann, S.
- Venue
- BMC Bioinformatics
- Published
- 2008-11-28
- Volume
- 9
- Issue
- 1
- Pages
- 504-504
- ISSN
- 1471-2105 (ISSN-L)
- OpenAlex
- W2168590651
- Cited by
- 1,185
- References
- 2
- FWCI
- 5.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive feature detection for high resolution LC/MS. https://app.cochat.ai/papers/10.1186/1471-2105-9-504
- The paper
- Tautenhahn, R., Böttcher, C., & Neumann, S. (2008). Highly sensitive feature detection for high resolution LC/MS. BMC Bioinformatics. https://doi.org/10.1186/1471-2105-9-504
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.