The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis
Open accessAbstract
BACKGROUND: Fluorescent data obtained from real-time PCR must be processed by some method of data analysis to obtain the relative quantity of target mRNA. The method chosen for data analysis can strongly influence results of the quantification. RESULTS: To compare the performance of six techniques which are currently used for analysing fluorescent data in real-time PCR relative quantification, we quantified four cytokine transcripts (IL-1beta, IL-6 TNF-alpha, and GM-CSF) in an in vivo model of colonic inflammation. Accuracy of the methods was tested by quantification on samples with known relative amounts of target mRNAs. Reproducibility of the methods was estimated by the determination of the intra-assay and inter-assay variability. Cytokine expression normalized to the expression of three reference genes (ACTB, HPRT, SDHA) was then determined using the six methods for data analysis. The best results were obtained with the relative standard curve method, comparative Ct method and with DART-PCR, LinRegPCR and Liu & Saint exponential methods when average amplification efficiency was used. The use of individual amplification efficiencies in DART-PCR, LinRegPCR and Liu & Saint exponential methods significantly impaired the results. The sigmoid curve-fitting (SCF) method produced medium performance; the results indicate that the use of appropriate type of fluorescence data and in some instances manual selection of the number of amplification cycles included in the analysis is necessary when the SCF method is applied. We also compared amplification efficiencies (E) and found that although the E values determined by different methods of analysis were not identical, all the methods were capable to identify two genes whose E values significantly differed from other genes. CONCLUSION: Our results show that all the tested methods can provide quantitative values reflecting the amounts of measured mRNA in samples, but they differ in their accuracy and reproducibility. Selection of the appropriate method can also depend on the design of a particular experiment. The advantages and disadvantages of the methods in different applications are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
A new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Vandesompele, J., De Preter, K., Pattyn, F., Poppe, B., Van Roy, N., De Paepe, A., & Speleman, F. (2002) · Genome Biology · doi:10.1186/gb-2002-3-7-research0034 · Cited by 20,038
Pfaffl, M. W. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.9.e36 · Cited by 7,376
Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data
Ramakers, C., Ruijter, J. M., Deprez, R. H. L., & Moorman, A. F. M. (2003) · Neuroscience Letters · doi:10.1016/s0304-3940(02)01423-4 · Cited by 3,709
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
Bustin, S. (2002) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0290023 · Cited by 2,546
Real-time RT-PCR normalisation; strategies and considerations
Huggett, J., Dheda, K., Bustin, S., & Zumla, A. (2005) · Genes & Immunity · doi:10.1038/sj.gene.6364190 · Cited by 1,856
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Quantification on the LightCycler
Rasmussen, R. (2001) · Rapid Cycle Real-Time PCR · doi:10.1007/978-3-642-59524-0_3 · Cited by 892
Schefe, J. H., Lehmann, K. E., Buschmann, I. R., Unger, T., & Funke-Kaiser, H. (2006) · Journal of Molecular Medicine · doi:10.1007/s00109-006-0097-6 · Cited by 859
Cited by
Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
Selective Release of MicroRNA Species from Normal and Malignant Mammary Epithelial Cells
Pigati, L., Yaddanapudi, S. C. S., Iyengar, R., Kim, D.-J., Hearn, S. A., Danforth, D., Hastings, M. L., & Duelli, D. M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0013515 · Cited by 582
Recent advances in quantitative PCR (qPCR) applications in food microbiology
Postollec, F., Falentin, H., Pavan, S., Combrisson, J., & Sohier, D. (2011) · Food Microbiology · doi:10.1016/j.fm.2011.02.008 · Cited by 479
Teste, M.-A., Duquenne, M., François, J. M., & Parrou, J.-L. (2009) · BMC Molecular Biology · doi:10.1186/1471-2199-10-99 · Cited by 465
Myalgic Encephalomyelitis/Chronic Fatigue Syndrome: A Comprehensive Review
Cortes Rivera, M., Mastronardi, C., Silva-Aldana, C., Arcos-Burgos, M., & Lidbury, B. (2019) · Diagnostics · doi:10.3390/diagnostics9030091 · Cited by 313
Metadata
- Authors
- Čikoš, Š., Bukovská, A., & Koppel, J.
- Venue
- BMC Molecular Biology
- Published
- 2007
- Volume
- 8
- Issue
- 1
- Pages
- 113
- ISSN
- 1471-2199 (ISSN-L)
- OpenAlex
- W2148367096
- Cited by
- 392
- References
- 22
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis. https://app.cochat.ai/papers/10.1186/1471-2199-8-113
- The paper
- Čikoš, Š., Bukovská, A., & Koppel, J. (2007). Relative quantification of mRNA: comparison of methods currently used for real-time PCR data analysis. BMC Molecular Biology. https://doi.org/10.1186/1471-2199-8-113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.